Loading...
HomeMy WebLinkAbout036 A402.pdfAe Clear from Clear from 1' - 10 1/2" VA.F. Detail @Crematory Stack 1 1-on Note: Crematory to be relocated by owner (NIC); Contractor shall be responsible for roof detail @ crematory stack, including framing, finishes, rain collar, flashing, etc. - coordinate installation with owner & crematory manufacturer (all details to be in accordance with crematory manuf. installation instructions), Wall Section @Main Building Fire Wall - Exterior 3/4" = l'-O" s across iverhang r Truss Beanrig.." 00 M em*ml ff a J"'h Detail @Garage Door Threshold 1'-0" M WITATIMA • Sallyport Bearing , 1 V- 5 1/2" Lower Truss Bearing 10' - 1 1/2" ZMMB == Sim 5 A401, C� ! 1 B.C. Soffit framing 2 121 _/316 eynote Legend K Keynote Legend Key Key Value Keynote Text Value Keynote Text i26 4" Conc. slab w/ 6x6 WWM on 15 mil vapor barrier on 6" 52 (2) Simpson 1/4" x 3" SDS screws at 12" O.C. to truss crushed stone on well PoTpacted soil 3" Thick Perimeter slab/foundation insulation board.), 53 bottom chord, typ. L6x6x3/8 V-0" �27 x clip angles @ 4'-0" O.C. fitted between (R-1 5), 2'-0" eadirection, typ. truss members, typ. w/ vertically long slotted holes at 28 x x 16 CMU - grout solid bolts 1 29 Insulated Sectional Garage Door - see schedule 54 ------ - (2) 5/8" Hilti RE 500 epoxy anchors @ U-0" O.C. @ each 130 Continuous Bond Beam w/ 2 #4 bars @ 24" oc. lap bars clip angle - embed 4" in CMU with no nut installed, typ. 2'@ splices (framing designed to pull away from CMU in event of fire) 31 1 Treated M 55 W8x21 - bear beam and plate 8" each end 32 13/4" Plywood 56 Infill w/ CMU 33 Return EIFS @ Head & Jamb 57 1/4" bottom plate 34 5/8" M.R. Gypsum Wallboard Ceiling 58 Flashing Collar - match metal roof 35 . ..... - (3) #5 bars continuous, lap 2'-3" @ splices 59 2x1 0 36 #4 dowels @ 48" O.C. w/ std. hooks in footing - grout 60 DbI 2x8 Header - - ---- solid @ dowels 61 Fiber cement panel 37 8" x 8" x 16" CMU 62 Fiber cement soffit 38 5/8" Plywood 63 New crematory unit rain collar (include in this contract - 39 5/4 x 6" "Azek" Soffit/Rake trim ll not by owner), install in accordance with crematory 40 1/2" Anchor Bolt @ 48" O.C. typ. manuf. details, including all counterflashing 41 11-1-1-11 _­­11 11111-1-- 11 ­­1­11 i Wall/roof flashing & counterflashing - match metal roof 64 Joist hangers, typ. 42 --- --- Hardie I I 11 Soffit Board 11 w/ I cant. - - - vent 11 I ------- 65 1/2" galvanized steel threshold plate wl 112" max lip typ @ garage doors 43 Joint Sealants 66_ Concrete Apron 44 1/16' x 1.5" GaIv. Steel Straps 16" oc. 6-7 Roadway Paving - refer to site drawings ings for details 45 Through Wall Flashing 46 20 ga. Corrugated Tie - Refer to specifications for s-pacing-­11- 47 EIFS reveal 48 '3/4" EIFS Projection 49 3/4" Expansion Joint 50 Vented Hardie Soffit Board 151 Continuous (stepped to match roof slope) Bond Beam w/ 2 #4 bars @ 24" o.c. lap bars 2'@ splices TT 1 �16 4 L4 00 /A\ Y Sall lyport'Bearing 11 5 41 /2 It t 34 I. 11 Lower Truss Bearing "op oaf Slab Top of Slab -1 op" of Slab A---� Top of T oil Or 01-011 -W _Slab 1IAw 77— vA - 14,M­-N 7 am , 2 27 T 1 0 of Foo,+,IN�_ a\ Top, of Footlqg_ Top of Footing Top of Footing,nii" 4-411 4 6 2 cr) L " Cl) 22 E 10 112" 553i8" 5 7/8"1 j Qi 111 5/6" EQ, ECG EQ 011 2- 0" Z 0" X 2 Section @Building to Salliport Firewall 314" = I$_011 0% Wall Secton @Sal I i port Gairage Door 4 Wall Section �gKennel End Wall 314" = 11.01$ 0) -leea CZ )0 c C\J W 0 0) E + Q) Lli C\1 < > 0 0 Z U! C; 4-a W 0 Cn %U 't CO ,I- 00 0 r-_ Cc < Cf) M 0 -71rz I (D U3 ICU FE U) CU Id 4.— C-) co (D C) v 5 CU 10 M E C= C) U) < :> M CU Co C-D CUqr- ftcu C:> Q PROJECT PHASE: Permit Drawings PROJECT#- DATE.- 0 9 0 2.12.27 or- coce liance - SED COM at ri