HomeMy WebLinkAbout020 C402.pdfROM
1. A MINIMUM OF 6" FROM OUTSIDE DIAMETER OF PIPE .. -1
TO SIDE OF TRENCH MUST BE ALLOWED FOR WASHED Al I
STONE. THE METHOD OF COMPACTING BACKFILL
MATERIAL IS SUBJECT TO APPROVAL BY THE ENGINEER.
AN APPROVED FILTER FABRIC SHALL BE PLACED
AROUND STONE AND OVERLAPPED 8" AT TOP. PIPE #57 WASHED STONE
SIZE TO BE SHOWN ON PLAN (MINIMUM 6" PIPE). PIPE do 6" to
TO BE SCHEDULE 40 PERFORATED PVC OR ADS N-12 110
PERFORATED PIPE AND SHALL BE APPROVED BY
ENGINEER PRIOR TO INSTALLATION.
2. SUBDRAIN PIPING SHALL BE NON -PERFORATED
UNDER PAVEMENT (INCLUDING SIDEWALKS AND i ®ILIF PERFORATED
-I
DRIVEWAYS U.N.O.). — VARIES PVC PIPE
3. THE OUTLET PIPES SHALL BE SCHEDULE 80 UNDER (6" MIN. U.N.O.)
ROADWAYS.
4. SEE SITE PLAN FOR SLOPE OF SUBDRAIN AND TIE
IN TO STORM DRAINAGE.
5. FILTER FABRIC SHALL BE AN APPROVED, TYPE 2
WATER PERMEABLE, SYNTHETIC FABRIC. APPROVED to
6. PREFABRICATED DRAINAGE MAY BE USED WITH FILTER FABRIC
APPROVAL OF ENGINEER OR AS NOTED ON PLAN.
TYPICAL SUBDRAIN INFILTRATION DETAIL FOR PIPING UNDER 15" IN DIAMETER
N.T.S.
NOTES:
1. A MINIMUM OF 24" FROM OUTSIDE DIAMETER OF PIPE TO
SIDE OF TRENCH MUST BE ALLOWED FOR COMPACTION OF FILL
MATERIAL. BACKFILLING OF TRENCHES SHALL BE III. I I BACKFILL
ACCOMPLISHED IMMEDIATELY AFTER THE PIPE IS LAID. THE FILL
AROUND THE PIPE SHALL BE PLACED IN LAYERS NOT TO
EXCEED 6". UNDER NO CIRCUMSTANCES SHALL WATER BE
PERMITTED TO RISE IN UN-BACKFILLED TRENCHES AFTER THE SHALLETER
T-OUTSIDE DIAMETER
PIPE HAS BEEN PLACED. COMPACTION REQUIREMENTS HALL
BE ATTAINED BY THE USE OF MECHANICAL TAMPS ONLY. EACH
AND EVERY LAYER OF BACKFILL SHALL BE PLACED LOOSE AND
THOROUGHLY COMPACTED INTO PLACE.
I II
2. ALL BACKFILL MATERIAL SHALL HAVE AN IN PLACE
COMPACTED DENSITY OF 95% STANDARD PROCTOR.
3. THE FINAL 2' BELOW FINISHED PAVEMENT GRADES SHALL BE
COMPACTED TO 100% STANDARD PROCTOR.
4. ALL TRENCHING OPERATIONS SHALL MEET OSHA
STANDARDS.
5. BACKFILL MATERIAL BENEATH ROADWAY SHALL BE SELECT
BACKFILL MATERIAL.
TYPICAL TRENCH DETAIL FOR INSTALLATION OF R.C.P. STORM DRAIN
N,T.S.
—NATIVE SOIL
TRENCHWIDTH BACKFILL
5- (MIN)—
Volum- -4.93 Galbbs (0.6602 cu, ft)
per linear Ft fbw Rate - 34.5 &:Am (1% Ajpe)
1
—616 CORRUGA:FED
PIPE. (Pdfo.#
I LAN VIEW
EZ-1501F
10,
Stmage Volume - 4.93 Gallons (0.664I2 cm 1)
per Bacar ft, flow Rate - 345 8pm (1% alope)
EZ-FLOW DRAIN SYSTEM FOR 6" CORRUGATED PIPE
N,T,S, (POR NON TRAFFIC AREAS)
TRENCH WIDTH
FT(MIN)
Ijk _7=7
SECTION
S"uge Vigil =x - LW QJ (0.14B cu. k)
W Ilnear ft Flow Rate- 90 8 Um (1% &3q=)
1 -0 A 0 a, VA I AWN
6
(TYP)
17lik
t7 IVP SOIL—T—NAT E
EZ-0701F
10,
SW=W Vol=e - 110 Gallons (0,1473 cu, fr-)
per linear ft Flow Raw - 801 Vm 0% 44c)
-3CO5 - TINTERNAL COUPLING
4
PIPE SHALL BE PLACED
ON SUITABLE MATERIAL
MDDE�,# 35-26-S
COLLAP Irl
NOTES.
1, ALL MATERIAL ExCEPT
PVC BOOT IS STEEL IS 30A
WELDED JOINT—
LLAR ID STS EEL ST
AINLES
PICO
iu L� STEEL IS POWDER COATED
tN STANDARD COLORS FIER
rUSTEMERS CHOICE
f-T-1
WLLDED JOINT
5/16 HOLE ON REAR
rOR MOUNTINCI
86'
315�X,1�5 X 1/8' CLEANOUT
CO, VER
FASTEND WITH SS PAN HEAD
HEX 1/4-20 X 112'
ATTACHED TO SS NUTS
WELDED TO INSHDF�
WELDED JOINT
NCH 40 4* OR 6* P\
pp ,---'ADAPTER
L
4, OR 6' NIRPLr
WELDED INTO
SQUARE TUBE
�'k_trrEs AT Vzrllrlrlllm
Im
BACKI;-_41
RECOMMENDED MINIMUM TRENCH WIDTHS
PIPE DIAM.
4"
MIN. TRENCH MDTH
21
23"
8.,
101,
26"
28"
12"
30"
151,
34"
18"
39"
z/
IN111A
24" 48"
SPRINGLINE
BACKFILL
30" 56"
H'UNC[I
3611 64"
4 1 CIF? 12 2 4" P1 PIE-BEDDING
42" 72"
6 [-'OR 30"-60" PIPE
48" 80"
SUITABLE
FOUNDA] ION
54R1 88
NOTE5: (SEA TAHLI
60" 96"
1. ALL PIPE SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ASTM D2321, "STANDARD PRACTICE FOR
UNDERGROUND INSTALLATION OF THERMOPLASTIC PIPE FOR SEWERS AND OTHER GRAVITY FLOW APPLICATIONS",
MINIMUM RECOMMENDED COVER BASED ON
LATEST ADDITION
VECHICLE LOADING CONDITIONS
2. MEASURES SHOULD BE TAKEN TO PREVENT MIGRATION OF NATIVE FINES INTO BACKFILL MATERIAL, WHEN
SURFACE LIVE LOADING CONDITION
REQUIRED,
PIPE DIAM.
HEAVY CONSTRUCTION
H-25
175T AXLE LOAD)
3. FOUNDATION: WHERE THE TRENCH BOTTOM IS UNSTABLE, THE CONTRACTOR SHALL EXCAVATE TO A DEPTH
12" - 48"
12" 48"
REQUIRED BY THE ENGINEER AND REPLACE NTH SUITABLE MATERIAL AS SPECIFIED BY THE ENGINEER. AS AN
ALTERNATIVE AND AT THE DISCRETION OF THE DESIGN ENGINEER, THE TRENCH BOTTOM MAY BE STABILIZED USING
5 60-t
24" 60"
A GEOTEXTILE MATERIAL.
* VEHICLES IN EXCESS OF 75T MAY REQUIRE ADDITIONAL COVER
4. BEDDING:- SUITABLE MATERIAL SHALL BE CLASS 1, 11 OR 111. THE CONTRACTOR SHALL PROVIDE
MINIMUM RECOMMENDED COVER BASED
DOCUMENTATION FOR MATERIAL SPECIFICATION TO ENGINEER. UNLESS OTHERWISE NOTED BY THE ENGINEER,
ONRAILWAYLOADING CONDITIONS
MINIMUM BEDDING THICKNESS SHALL BE 4" (100mm) FOR 4"-24" (100mm-600mm); 6" (150mm) FOR 30"-60"
COOPER
(750mm-900mm).
PIPE DIAM.
5. INITIAL BACKFILL SUITABLE MATERIAL SHALL BE CLASS 1, 11 OR III IN THE PIPE ZONE EXTENDING NOT LESS
UPTO 24" 24"
THAN 6" ABOVE CROWN OF PIPE. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL SPECIFICATION
30"-36" 36"
TO ENGINEER. MATERIAL SHALL BE INSTALLED AS REQUIRED IN ASTM D2321, LATEST EDITION.
47'-60$48"
6. MINIMUM !QQVER: MINIMUM COVER, H, IN NON -TRAFFIC APPLICATIONS (GRASS OR LANDSCAPE AREAS) IS 12"
COVER IS MEASURED FROM TOP OF PIPE TO BOTTOM
FROM THE TOP OF PIPE TO GROUND SURFACE. ADDITIONAL COVER MAY BE REQUIRED TO, PREVENT FLOATION.
OF RAILWAY TIE.
FOR TRAFFIC APPLICATIONS, MINIMUM COVER, H, IS 12" UP TO 48" DIAMETER PIPE AND 24" OF- COVER FOR
E-80 COVER REQUIREMENTS, ARE ONLY APPLICABLE
54"-60" DIAMETER PIPE, MEASURED FROM TOP OF PIPE TO BOTTOM OF FLEXIBLE PAVEMENT OR TO TOP OF RIGID
TO ASTM F 2306 PIPE.
PAVEMENT.
TYPICAL TRENCH DETAIL FOR FINISH INSTALLATION OF ADS N-12 PIPE
N.T,S
NPDES Stormwater Discharge Permit for Construction Acti\Aties (NCGO1 ) NCIDENRtDivision of Water Quality
NEW STABILIZATION TIMEFRAMES
(Effective Aug. 3,2011)
SITEAREADESCRIPTiON STABILIZATION TiMEFRAME EXCEPTIONS
Perimeter dikes, swales, ditches, slopes 7 days None
......... .
High Quality Water (HQW) Zones 7 days None
If slopes are 10' or less in length and are
Slopes steeper than 3:1 7 days not steeper than 2*1, 14 days are allowed.
Slopes 3:1 or flatter 14 days 7 days for slopes greater than 50' in length.
All other areas with slopes flatter than 4,1 14 days one except for perimeters and HQW Zones.
GRADING STABILIZATION TIMEFRAMES
IT SHALL SE THE CGIM40TORS RES ITY
TO CON TA C T 7W CZI W1 EVa��R TO #VStb5E_ THA T
ALI PARTIES ARE hV PC��� OF THE MST
CURRENT SET OF CnV5TRUC77CW DOC��M
BEFORE COIO
VS7RtICTION COMMENCES.