Loading...
HomeMy WebLinkAbout014 C202.pdfgullomi Illimum- Plil INSTALL SAFETY RAIL ALONG TOP OF WALL CAP TO MATCH nCrIADA-MIC Of APE/ FHQNJ OF ]HE BUILUINU CONCRETE SLAB - SEE PLAN SLOPE 1/4'/FT. AWAY FROM WALL A A A A, A A A 2 #4 BARS #4 BARS 0 16-- BACKFILL WITH SUITABLE MATERIAL TO OBTAIN 95% S BARS COMPACTION. #4 @ 32" 12" CMU BLOCK CON11NUOUS POCKET OF CLEAN GROUT SOLID COURSE GRAVEL W/ FILTER FABRIC. HARDWARE CLOTH CENTERED BEHIND WEEP HOLE BAR SPLICE 40 BAR H=4' MAX DIA. MIN. 4*" PERFORATED PIPE DRAIN W/FILTER SOCK j (OPTIONAL) �ry 'r, 2" PVC WEEP HOLE 7' NO ES:__ y 1. CONCRETE & GROUT STRENGTH 3,600 PSI 010' MIN (TYP). SECURE 12"X12" GALVANIZED WIRE -V 2. STEEL REINFORCING STRENGTH 60,000 PSI MESH AT BACK FACE OF WALL 3. ALLOWABLE SOIL BEARING STRENGTH = 2,000 PSF 12#p 4. GROUT ALL CMU CELLS SOLID 12" 77 5. PIPE UNDER -DRAINS CAN BE USED BEHIND WALL -61p INSTEAD OF WEEP HOLES IF ABLE TO MAINTAIN 12" POSITIVE FLOW TO DAYLIGHT. ENCASED IN 1'X3' GRAVEL W/ FILTER FABRIC (TYP.) 3" .4 6. BAR LAPS- 40 BAR DIA. MIN. I 1 2ps - . , , 6 . 1/2" RAID. ON ALL EDGES SEE PLANS BUILDING SIDE (RIGID STRUCTURE) 3600 PSI CONCRETE 1-/4"-/FT. 6" TYP. 4 \-6" SUBGRADE SCARIFIED & - 6" MIN. COMPACTED TO A MINIMUM 95% STD. PROCTOR DENSITY (ASTM D 698) WITHIN -1% TO +3%. NOTES: 1. CONCRFIF SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3600 PSI AT 28 DAYS, 2� SURFACE SHALL BE ROUGH NON-SKID TYPF. STIFF BROOM FINISH PFRPENDICULAR TO TRAFFIC FLOW. 3� ALL SIDEWALKS SHALL HAVE CROSS --SLOPE OF 1 /4" PER FOOT TO DRAIN TOWARDS STREET OR AWAY FROM BUILDINGS. 4� CONTROL JOINTS SHALL BE PLACED AT INTERVALS EQUAL TO THE WIDTH OF THE WALK UNLESS 01-HERWISE DIRECTED BY THE ENGINEER, HAND TROWEL SCORE JOINT 1/2" X 1" DEEP, TOOLED JOINTS TO EXTNFD FULL WIDTH OF SIDEWALK. 5. CONSTRUCTION JOINTS SHALL BE INSTALLED A DISTANCE NO GREATER THAN 100'. INSTALL 3 30" #4 BAR DOWELS WITHIN FORMED JOINTS FOR EVERY 5'--01" WIDTH OF SIDEWALK. 6� INSTALL 1/2" EXPANSION JOINT AGAINS-1- ALL RIGID STRUCTURES (SEALED). EXPANSION jOl,-",IT SHALL BE 1/2" THICK PIFCF OF BITUMINOUS FIBER OR OTHER MATERIAL APPROVED BY ENGINEER. TYPICA SIDEWALK SECTION WIN .0, 7 N.T.S, MASONRY ENCLOSURE SHALL MATCH THE ANIMAL SHELTER'S GROUND LEVEL SPLIT -FACED DECORATIVE CMU VENEER. WALL HEIGHT SHALL BE 7-4" ± A.F.F. w w . , I . . . I . H BARS MAINIAIN J ULLAM %�VVr_M rkJM AL-L Mr_llXrVRkANu N.T,S, SLOPE PAD TO 4 #5 0 16" BARS IN CONCRETE FOOTING. DRAIN OUT THE #4 BARS (TYP.) 8. CONTACT ENGINEER IF HEIGHT (H) IS GREATER FRONT. T BARS 3#-611 THAN 4' OF IF THERE IS A SURCHARGE TO BE #5 0 16" PLACED NEXT TO THE WALL. MINIMUM 10' X 10'- BLOCK RETAINING WALL ADJACENT TO CREMATORY PADDOCK 1/8" RADII (TYP.) INSIDE CLEARANCE N.T.S. DUMPSTER PAD SHALL BE PLACED WITH A CONCRETE HAVING A MIN. COMPRESSIVE STRENGTH OF 5,000 PSI AT 28 DAYS AND 6% A B c 1" MIN DEPTH CUT OR ENTRAINED AIR OVER 4" THICKNESS OF SAWCUT OR STRIPABLE 1/40FSLAB DEPTH CRUSHED AGGREGATE BASE COURSE (ABC) CONTROL JOINT AS REQUIRED. COMPACTED TO 100% STANDARD PROCTOR, FILL W/ JOINT SEALER MAXIMUM DRY DENSITY (ASTM D698). n- COMPACT SUBGRADE TO A MINIMUM 95% STD. PROCTOR DENSITY (ASTM D 698) WITHIN -1% TO + 3%. A p rr)klrP[=Tl= rr)KITPAr.TIr)I`\I/rr)I`\ITPr) lr)INIT nFTAI ON ALL SIDES a ".Tv Lo 0) )F WALL 1, ALL CONCRETE TO BE 3600 P.S.I. COMPRESSIVE S-IRENGTH. 2. TYPE OF PIPE TO BE USED IS 1-5/8- MAX. O.D. BLACK IRON, LOW CARBON PIPE OR GALVANIZED. 3. ALL JOINTS TO HAVE A 1/2- FILLET WELD AT ALL JOINTS. 4-, AFTER INSTALLATION PAINT ASSMBLY WITH BLACK ALL WEATHER ENAMEL. TYPICAL SAFETY RAIL N.T.S. PLAN NT$ TYPE "BELOW GRADE ,--10' MIN. A -10 MIL PLASTIC LINING 10 MIL PLASTIC LINING B--------- STAKE v WOOD FRAME SECURELY t TIRE FASTENED AROUND "N' PERIMETE,ER IMTH TWO STAKES 10 MIL PLAS-flC LINING TWO-STACKED��_ PLAN _B_ 2 X 12 ROUGH NTS NTS WOOD FRAME TYPE "ABOVE GRADE" w TEMPORARY CONCRETE WASHOUT FACILIT N.T.& PROP. 12' X 18' DUMPSTER V-0, PAD WITH 8" THICK CONC. SLAB W/6xPj 8/8 W.W.F. ON 4" STONE BASE W1 TURN DOWN FTG. AROUND CONC. rA .11 r_ APRON. THIS SIGN REQUIRED ONLY AT VAN ACCESSIBLE SPACES RESERVED' PARK�NG (1 IN 8 OR MIN, OF 1) 00 MT FX z p 16 A rl LTY UM 2501 < E 07- a- < _1� - z Z ck� < 0 Fr z < LLI cl Fy Z_ F_ =) _,) V) V) - Lij V) r') (11) Ld CE 0 Ld < uj z z 0 3�: V) Ld ,�o o cf) -.q- < 8' TALL MIN. HEAVY DUTY GALVANIZED U-CHANNEL POSTS, 2 LBS/FT, IN WEIGHT (o n oc) CL COLORS LEGEND AND BORDER -- GREEN WHITE SYMBOL ON BLUE BACKGROUND BACKGROUND - WHITE �TO GRADE TYPICAL HANDICAP SIGN DETAIL NOT TO SCALE rCLE A N Ot J T i' COVER IN CENTER OF PAD CAST IRON CLEANOUT WITH COVER OR APPROVED EQUAL FINISHED GRADE OR PAVING 4" EXTENSION U.N.O� ON PLAN !==Ill� ,--i 00 TOP VIEW -CONCRETE PAD ,.",,,,-l8'!xl8"x4" THICK \11, CONCRETE PAD 0 _-���CONCRETE OR CONCRETE BLOCK FOR SANITARY SEWER LATERALS NOTES. 1. SEE PLAN FOR LATERAL PIPE SIZE. 2, LATERAL SHALL BE SCH 40 PVC OR D.I. PIPE. 3. USE TEE/WYES FOR PVC PIPE. 4. IF DEPTH IS GREATER THAN 12', ENTIRE PIPE LATERAL SHALL BE D.I.P. 5. SANITARY SEWER LATERALS MUST HAVE 3' MIN. COVER. & FOUNDATION STONE REQUIRED WHEN SOIL CONDITIONS ARE UNSTABLE. 7. TRENCH CLEAR DISTANCE NOT LESS THAN 6" OR MORE THAN 12" EACH SIDE. INITIAL, BACKFILL SHALL BE PLACED IN 6" LIFTS AND COMPACTED, INITIAL BACKRLL SHALL CONTAIN NO MATERIAL OVER 1-1/2" IN DIAMETER, FROZEN LUMPS, OR DEBRIS. 9� BACKFILL SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY, STORM OR SANITARY LATERAL AND CLEANOUT DETAIL Im-1 Z N N r X ME 0 Lei I fill A l'-O" x 2'-0" 3,600 PSI CONC. FOOTING W/3 #5 BARS CON11NUOUS AND #3 TIES 0 32" O.C. PROVIDE 1' MINIMUM COVER OVER FOOTING. SOIL BEARING CAPACITY SHALL BE 2 000 PSF MINIMUM. D U M P S TE R . FIR OM THE STRUCTURE AT V PER FOOT TO ALLOW FOR ADEQUATE DRAINAGE U.N.O. RLINF SPI 1 F­ F ACED !"'MU BLOCK FILLED SC)LID WITH MIIN� _31,600 PSI ii. ACCESSIBLE PARKING SPACES AND ACCESS AISLES MAY HAVE A Y4 INCH PER FOOT CONCRETE PROVIDE- HORIZONTAL JOINT MAXIMUM SLOPE IN ALL DIRECTIONS FOR DRAINAGE. THE CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTING ACCESSIBLE PARKING, AISLES, SIDEWALKS AND RAMPS IN RLINFORCEMENT 4 16" O.C. AND #5 ACCORDANCE WITH THE NC ACCESSIBILITY CODE OR CURRENT FEDERAL ACCESSIBILITY V -FICAL BARS @ 32 " O,r, E R - TO 6 0" A.F 1 CODE. INS -FALL SPLlT--FA(_1[._i-, CMIJ CAP, 12. CONTACT NEWTON PUBLIC UTILITIES DEPARTMENT FOR NOTIFICATION AND UTILITY LOCATE 72 HOURS PRIOR TO BEGINNING U11LITY WORK. SHOULD BE INSTALLED 4' APART AND 1' FROM ADJACENT 13. HANDICAP SYMBOLS SHALL NOT BE PAINTED ON ASPHALT PER NCAC PAGE 38 SCREENING MATERIALS TYP. GENERAL NOTE # 2. THE HANDICAP SYMBOLS ARE SHOWN FOR LOCATION PURPOSES r ONLY. SIGNS ARE TO BE PLACED TO INDICATE ACCESSIBLE PARKING SPACES. "NO 4" MIN. 0 GALV. STEEL POSTS ANCHORED 14. ALL FIRE LANES AND ACCESS ROADS MUST BE MARKED WITH SIGNS INDICATING MIN. 3' BELOW SLAB (SEE CHAIN LINK PARKING FIRE LANE". SIGNS SHALL MEASURE 12 INCH BY 18 INCH AND HAVE RED 7 FENCE DETAIL FOR FOOTING DETAILS) LETTERS ON A WHITE REFLECTIVE BACKGROUND. SIGNS MUST BE METAL CONSTRUCTION W/4- HEAVY DUTY HINGES AND CAP. ONLY. SIGNS SHALL BE MOUNTED AT A MINIMUM HEIGHT OF FOUR FEET TO THE MAXIMUM OF SEVEN FEET. SIGNS SHALL BE PLACED ALONG THE FIRE LANE AT INTERVALS NOT TO EXCEED 50 FEET AND AS DESIGNATED BY THE FIRE CODE OFFICIAL. PROP. 6'-0" MIN. HEIGHT CHAIN LINK GATE. GATES SHALL HAVE GALV. HASP 15. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING ROADS DURING wAOCK (HANDLES) AND DROP ROD. CONSTRUCTION AND SHALL REPAIR ROADS PER REQUIREMENTS OF NCDOT AND THE CITY OF NEWTON. NO OPEN CUTS OF EXISTING ROADS SHALL BE ALLOWED EXCEPT WHERE -INSTALL WINGED PVC PRIVACY SLATS. MIN. INDICATED ON THE DRAWINGS OR WHERE SPECIFIC PERMISSION IS GRANTED BY THE ROAD '\--PERIM�_TER TURN HEIGHT SHALL BE 6', WINGED PVC SLATS OWNER. ALL EXISTING PAVED SURFACES SHALL BE PROTECTED FROM TRACK EQUIPMENT BY HOOVER FENCE CO. OR APPROVED AND OTHER CONSTRUCTION OPERATIONS. PROTECTIVE BARRIERS SHALL BE UTILIZED AND DOWN- EQUAL. VERIFY PRODUCT AND COLOR WITH APPROVED BY THE ROAD OVIER. EXISTING ROADS SHALL MAINTAIN CLEAR OF DEBRIS ARCHITECT PRIOR TO PURCHASE AND AND SHALL BE CLEANED UP PROPERLY AFTER CONSTRUCTION. DUMPSTER DETAIL INSTALLATION. N,T,S. UTILITY NOTES 1. ALL MATERIALS AND CONSTRUCTION OF WATER AND SANITARY SEWER LINES SHALL BE IN 5" DIAMETER 1/2" ACCORDANCE WITH THE LATEST CITY OF NEWTON LAND DEVELOPMENT DESIGN AND CONSTRUCTION " I PE, F-i'LLED W/CONC. STANDARDS. 3OLLARDS SHALL BE #4BARS :1ANTEE", YELLOW. F 2. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING TRENCH SAFETY REQUIREMENTS IN ACCORDANCE WITH CITY STANDARDS, NORTH CAROLINA STATE LAW, AND O.S.H.A. STANDARDS FOR ALL ADJACENT PAVING X_ 8 X-X--7----x EXCAVATION OF MORE THAN FIVE FEET. 3. THE LOCATION OF ALL UTILITIES LOCATED ON THESE PLANS ARE TAKEN FROM RECORD ENGINEERING PLANS AND SURVEYS. THE EXACT LOCATION AND ELEVATION OF ALL PUBLIC UTILITIES MUST BE DETERMINED BY THE CONTRACTOR. IT SHALL BE THE DUTY OF THE CONTRACTOR TO ASCERTAIN WHETHER ANY ADDITIONAL FACILITIES OTHER THAN THOSE SHOWN ON THE PLANS MAY BE PRESENT. CONCRETE FOOT11',10� 4. WATER & SANITARY SEWER LINES SHALL BE INSTALLED AS SHOWN ON PLANS. THE 12" WATEA" MAIN TO SERVE THE ANIMAL SHELTER SHALL BE INSTALLED UNDER SEPARATE CONTRACT. LINE WORK IS SHOWN FOR REFERENCE ONLY, FOR DETAILED CONSTRUCTION DOCUMENTS SEE PLANS PREPARED BY ATRIAX, PLLC. ALL WORK FOR WATER SERVICE LINE AND AND SERVICE CONNECTION TO BE INSTALLED UNDER THIS CONTRACT. SEE PLANS HEREIN FOR LENGTH OF SANITARY SEWER LATERAL TO BE INSTALLED, 5. WHEN P.V.C. PIPE IS USED FOR WATER MAINS, WATER SERVICE LINES AND SANITARY SEWER I LATERALS A NO. 1 UNSHIELDED COPPER WIRE OR AN APPROVED METALLIZED FOIL CORE TAPE IS TO BE INSTALLED WITH THE PIPE. TO PROTECT ALI PUBLIC AND FRANCHISE roLIRRf NT SET OF C01VS'7Rt1C77CW DOC��75� S. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR i SEf-ORE CVA�57RUC776W COMAIE UTILITIES IN THE CONSTRUCTION OF THIS PROjEACT. I A A W011:11,1116 "Wip /r SHAL-1 LRE TRE CONTRACTOR5' RLSPON-51BItITY To CON TA C 7- 7�� Cl VIL ENGINEER TO INSURE 7�01 7- 8. BACKFILL FOR UTILITY LINES, PAVEMENT CUTS AND PAVEMENT REPLACEMENT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE 01-Y OF NEWTON LAND DEVELOPMENT DESIGN STANDARDS.