Loading...
HomeMy WebLinkAbout008 T102.pdfBuilding 1 Area (Section 503). 12,207 GSF Less exterior covered area directly accessible to exit discharge: 1,320 GSF Less area devoted exclusively to animals: 2,204 GSF Area used in Occupant Load Calculation: 10,887 GSF Occupant Load Rate (Business Areas) (Area shown per occupant): 100 GSF Occupant Load: 101 Minimum Number of Exits Required (1021.1): 2 Number of Exits Provided: 9 Building 2 (Exclusive of Sick Animal Holding Alternate)(Section 503): 3,817 GSF Less exterior covered area directly accessible to exit discharge: 290 GSF Less area devoted exclusively to animals: 914 GSF Subtotal Bldg 2 Area used in Occupant Load Calculation: 2,613 GSF Sick Animal Holding Alternate Area: 698 GSF Less exterior covered area directly accessible to exit discharge: 132 GSF Less area devoted exclusively to animals: 408 GSF Subtotal Sick Animal Holding Alternate Area: 158 GSF Total Area Building 2 + Sick Animal Holding Alternate Area (Section 503): 4,515 Total Area Building 2 + Sick Animal Holding Alternate Occupant Area (Section 1004): 2,771 Occupant Load Rate (Business Areas) (Area shown per occupant): 100 GSF Occupant Load: 28 Minimum Number of Exits Required (11021.1): 2 Number of Exits Provided: 4 Building 3 (Exclusive of Rescue/Foster Animals Alternate)(Section 503)- 2,063 GSF Less exterior covered area directly accessible to exit discharge: 386 GSF Less area devoted exclusively to animals: 1,234 GSF Subtotal Bldg 2 Area used in Occupant Load Calculation: 443 GSF Rescue/Foster Animals Alternate Area: 870 GSF Less exterior covered area directly accessible to exit discharge: 164 GSF Less area devoted exclusively to animals: 504 GSF Subtotal Rescue/Foster Animals Alternate Area: 202 GSF Total Area Building 3 + Rescue/Foster Animals Alternate Occupant Area (Section 1004): 645 Occupant Load Rate (Business Areas) (Area shown per occupant): 100 GSF Occupant Load: 7 Minimum Number of Exits Required (1021.1): 2 5Number of Exits Provided- 2 Exit: 3-Ox7-0 Door. Max. Egress Capacity: 170 Occupant Load: 9 Max. Exit Access Travel: 78' ol Life Safety Plan Life Safety Plan Notes: 1. Exterior Wall Opening Area: Section 705.8: No Limit (>30', UP/NS) 2. Doors with Panic Hardware: None required (1008.1.10: No H or A Use Group, no space occupant load >50), none provided. 3. Doors with delayed egress locks and amount of delay: None required, none provided. 4. Location of emergency egress windows: None required (1029.1: No Group F classrooms, no R or 1-2 Use), none provided. 5. Building 1 Fire Area: 12,207 square feet. Building 2 Fire Area: 4,515 square feet (includes alternate). Building 3 Fire Area: 2,933 square feet (includes alternate). 6. Smoke Compartments: None required (407-1: not Use Group 1-2), none provided. 7. NFPA 10 Hazard Classification: Light (low) Hazard. 8. Primary Fire Classification: Class A (ordinary combustible materials). Exit: 3-Ox7-0 Door. Max. Egress Capacity: 170 Occupant Load, 7 Max. Exit Access Travel: 70' 1 1Z Rescue 1 Foster Animals 531 174 SF wE 411 ttma X1 Exercise Yard X, z X '>C ",I% X Buildim) 0 Gross SF��`: 2,9,3o Z � XX X 'w Ir X Canine Holding _41 I'll 'X CV 415 SF 1/,,' 7 X 0, X 1 X - �11 A , > AV IX, t - "A _7 %K 2 Hour Rated Fire Wall. U.L. Design "j, X�' V� No. U905 'K 4 121-1, \41 X K X Exit: 3-Ox7-0 Door, Max. Egress Capacity: 170 OccupantLoad: 25 Max. Exit Access Travel: 87' �s onn r o� Stray C A leatill Ill 'Men's Staff 4 r 11Vwomen's staff Toilet -Toilet Exit 3-Cx7-0 Door. Max. Egress Capacity: 170 Chief ACO Offic, Occupant Load: 15 0 Max. Exit Access Travel: 72' I SF 'J % IINI'�,,-,,��g, 4 aun ', 1A :L dry Buildim 2 y IFw. A 4,515 Uross, SF 29' "t"'on, t it CI IC Exit: 3-Ox7-0 Coors. Max. Egress Capacity: 170 Occupant Loa ; 18 Max. Exit ACCE ss Travel: 87' Exit: 3-Ox7-0 oors, Max. Egress Dapacity: 170 Occupant Load: 17 Max. Exit Access Travel: 93' Adoption Courtyard Building Area With Direct Access to Exit Discharge. Building Area Devoted Exclusively to Animals. Building Area As Defined By Section 503. Portable Fire Extinguisher FE Rated 2A: 1 OBC Minimum in Recessed Cabinet (See Specifications). Exit Door Clear Widths (Typ.) For 3-0 Doors: 34 inches. For Paired 3-0 Doors: 70 inches. Egress Occupant Counter No. Of occupants traveling in direction of top arrow. No. of occupants traveling in direction of bottom arrow. Egress Path Exit: 3-Ox7-0 Door. Exit: 3-Ox7-0 Door. Max. Egress Capacity: 170 Max. Egress Capacity: 170 Occupant Load: 2 Occupant Load: 24 Max. Exit Access Travel: 0' Max. Exit Access Travel: 103 C 1rc) i/ xit: (2) 3-0x7-0 Do rs' Aax. Egress Cap 9 c : 350 T37 SF )ccupant Load- 1 3 vlax, Exit Access Trj y vel. 52' Exit: 3-0x7-0 Doors. Max. Egress Capacity: 170 Occupant Load: 9 011 Exit: 3-Ox7-0 Door. Max. Egress Capacity: 170 Occupant Lead: 7 Max. Exit Access Travel: 70' K ,,Cx,28 L" Exit: 3-0x7-0 Door. IX Max. Egress Capacity: 170 Occupant Load: 21 Max. Exit Access Travel. 89' Exit: 3-Ox7-0 Door. Max, Egress Capacity: 170 Occupant Load: 27 Max. Exit Access Travel: 89' I 0% kmd -Ina ■ CIQ W N 0 5 0) cli E 0 W N < > 0 0 Z L11 6 Cn W 0 cn A% Uj > co -t co Uj 00 00 CO (0 1: F- 0 Q 0) ;.NJ No 0 T— 0: < NI co 0 0 I. 1— 2 2 -2� (D < U) cu co CU ED Cn co i r% C> CU 3: Igo CD PROJECT PHASE: P*1t Drawings