Loading...
HomeMy WebLinkAboutOP-2-10-4422.TIF OPERATION PERMIT or ice use only Catawba County Public Health Department *CDP File Number a 3 4 4 a Environmental Health Division WLS2009-00079 P.O Box 389, 100-A Southwest Blvd County ID Number: Newton NC 28658 Evaluated For: NEW Phone: (828)-465-8270 Fax: (828) 465-8276 Township Applicant: Property Owner: GRAHAM! Yu I ~iG'~ Address: Address: 1600 FLOYD RD City: CRY: COLUMBUS State/Zip: State2ip: GA 31907-420 Phone Phone Property & Site Information Address/Road Subdivision: Phase: Lot: 3 _ 3534 MELINDA LN p CLAREMONT NC Directions Structure: SINGLE FAMILY FROM CLAREMONT/ SOUTH ON S MAIN (BETHANY) CROSS BRIDGE/ 1ST LFT (MELINDA # of Bedrooms: 2 LN)/ PROPERTY STARTS PAST TRAILER ON LIFT # of People: 2 AT 1 ST IRON STAKE Water Supply: EXISTING WELL *IP Issued by: 9999-Unknown 'System Class ification/Description: TYPE 111 G. OTHER NON-CONV. TRENCH SYSTEMS 'CA issued by: 1952 - Phelps, Robert Design Flow: a 4 0 "Distribution Type: GRAVITY Soil Application Rate: 3 'Pre-Treatment: Drain field N itrifit:ation Field 6 0 0 Sq. ft. 'System Type: INFILTRATOR QUICK 4 STANDARD No. Drain Lines a Installer: Gary Leatherman Total Trench Length: a 0 0 ft. Certification 1111 Trench Spacing: - 9 Inches O.C. Feet O.C. "EH S: 1919 -Susan Miller Trench Width: 3 Inches Feet Date: 1/ 1 5/ 2 0 1 0 Aggregate Depth: inches Minimum Trench Depth: 0 Inches Minimum Soil Cover. 8 Inches Approval Status Maximum Trench Depth: 4 Inch ® Approved O Disapproved Inches Maximum Soil Cover. 1 a Inches Pagel of 4 CDP File Number 27442 County ID Number: WLS2009-00079 Septic Tank Manufacturer Gamewell Septic Tank Lat. STB: 160 Long: 1000 Installer: Leatherman Gallons: Date: 9 8 / x 0 0 9 Certification 1111 / `EH S: 1919 - Susan Miller "Filter Brand: POLYLOK PL-68 Date: 1/ 1 5/.1 0 1 0 ST Marker: ®Y@S ❑ NO Approval Status Reinforced Tank: El Yes @E No ® Approved ❑ :D-isapproved 1 Piece Tank: ❑ YeS ~ NO Pump Tank Manufacturer. Installer: PT: Certification Gallons: `EH S: Date: Date: Riser Sealed ❑ Yes ❑ No RiserHeight: ❑ Yes ❑ NO (Min.6 in.) Approval;„Status Reinforced Tank: ❑ Yes ❑ No ❑ Approved ❑ Disapproved 1 Piece Tank: ❑ YeS ❑ NO Supply Line Pipe Size: 3 inch diameter Installer: Leatherman Pipe Length: 4 a feet Certification 1111 'EH S: 1919 - Susan Miller *Schedule: 40 Pressure Rated ❑ Yes W No Date: 1/ 1 5/.2 0 0 9 Approved fittings ® Yes ❑ NO Approval Status ® Approved ❑ Disapproved Pump Requirement Pump Type: Installer: Dosing Volume: - Gal Certification Draw Down: Inches `EH S: "Chain: Date: Valves Accessible ❑ Yes ❑ No Flow Adjustment Valve ❑ Yes ❑ NO Check-valve ❑ Yes ❑ No Approval. Status PVC Unions ❑ Yes ❑ No ❑ Approved ❑ Disapproved Vent Hole ❑ Yes ❑ No Anti-siphon Hole ❑ Yes ❑ NO Page 2 of 4 CDP File Number 27442 County ID Number: wLS2009-00079 Electric Equipment NEMA 4X Box or Equivalent ❑ Yes ❑ No Installer: Box 12 inches Above Grade ❑ Yes ❑ No Certification Box Adj. To Pump Tank ❑ Yes ❑ No Conduit Seated ❑ Yes ❑ No 'EH S: Pump Manually Operable ❑ Yes ❑ No 'Activation Method: Date: Alarm Audible ❑ Yes ❑ No Approval' Status ❑ Approved El Disapproved Alarm Visible ❑ Yes ❑ No 1919 - Susan Miller 'Operation Permit completed by: n Authorized State Agent: &"A Date of Issue: 1 / .2 9 / a 0 1 0 This system has been installed in compliance with applicable NC General Statutes: Article 11, Chapter 130A, Rules for Sewage Treatment and Disposal, 15A NCAC 18A.1900 et. Seq., and all conditions of the Improvement Permit and Construction Authorization. This property is served by a TYPE III G. sewage septic system. Rule .1961 requires that a Type TYPE III G. septic system meet the following criteria: Minimum System Review By The Local Health Department: N/A Management Entity: OWNER Minimum System Inspection/Maintenance Frequency By Certified Operator: N/A Reporting Frequency By Certified Operator: N/A Rule .1961 requires that a Type IV and V septic systems designed fora hometbusiness owner must maintain a valid contract with a public management entity with a certified operator or a private certified operator forthe life of the septic system. Rule .1961 requires that Type VI septic systems designed fora home/business owner must maintain a valid contract with a public management entity with a certified operator for the life of the septic system. Rule. 1961 (2) (e) requires a contract shall be executed between the system owner and a management entity priorto the issuance of an Operation Permit for a system required to be maintained by a public or private management entity, unless the system owner and certified operator are the same. The contract shall require specific requirements for maintenance and operation, responsibilities of the owner and systems operator, provisions that the contract shall be in effect for as long as the system is in use, and other requirements for the continued proper performance of the system. It shall also be a condition of the Operation Permit that subsequent owners of the systems execute such a contract. OHand Drawing *Import Drawing **Site Plan/Drawing attached.** Total Time:(HH:MM) 0 0 Hours 0 0 Minutes Page 3 of 4