HomeMy WebLinkAboutBlackburn Landfill Building 5-11-99w WORK SHEET FOR NORTH CAROLINA EXTERIOR ENVELOPE DATE: 05-May-99 MODEL: F02364774 ACTUAL LENGTH COUNTY ZONE GO, NOGG OVERALL WIDTH BUNCOMBE 6 OK SIZE: 11.67 x 32 ANNUAL HEATING DEGREE DAYS: 4042 OCCUPANCY HVAC CFM7HEAT CEILING HEIGHT: 8.0 FT. 53.00 H. 4 390WINDOW SIZE:(A) 24:D0 IN. W. X N0 NO # OF LIGHTS TONAGE NO. OF WINDOWS:(A) 2 INSULATED GLASS: 6 I WINDOW SIZE:(B). IN. W. X IN. H. CHECK OR N0. OF WINDOWS:(B) INSULATED GLASS: WINDOW slzE:(c) IN. W. x NO. OF WINDOWS.(C) INSULATED GLASS: 8p.00 IN. H. Steel Door DOOR SIZE: (A) 36.00 IN. W. x IN. H. Commercial Door DOOR SIZE: (B) IN. W. x NO. OF DOORS: (A) 3 NO. OF DOORS: (B) Zone 3 Zone 4 Zen _5 Z O N E 6 Zone 7 CODE REQUIREMENTS Zone 1 Zone 2 0.081 0.®7i D p73 0.048 FLOOR (Uo FLOOR 0.105 0.112 0.085 0.184 0-1 0. 169 0.12675 WALL (Uo WALL) 0.234 0.248 0.189 0.066 0.068 0.066 0.07 0.055 ROOF (Ors ROOF) 0.077 Q.075 69 69 69 fig IN DESIGN TEMP: 69 69 69 14 18 10 1 OUT DESIGN TEMP- 25 22 lb . R VALUE CALCULATIONS R @ CAVITY Y R @ JOIST FLOOR 0.920 0.920 INSIDE AIRFILM 0.050 0.050 1/8" V.C. TILE 4.781 5/8° PLYWOOD DECKING 0.781 0.000 FIBERGLASS INSULATION 11.000 9:063 7 1/4" WOOD JOIST 0.170 OUTSIDE AIR FILM 0.170 0.-05p ..040.BOTTOM BOARD 0.050 M _ ------- R TOTALS - FLOOR - 12..971 11.034. U=I/R:= 0.077 U=1/R= 0.091 ADJUSTED U-VALUE = 0.078 R..@ CAVITY R @STUD WALL 0.170 p.150 0.150 OUTSIDE AIRFILM 0.150 5/16" HARDI PANEL FIBERGLASS INSULATION 11..000 . 4 375 3 1/2" WOOD STUD _ 0.450 WALL COVERING (1/2" GYPSUM) 0.450 INSIDE AIRFILM 0.680 0.680 ---- -- R TOTALS - WALL 12.450----- 5.825 U=I/R = 0.080 U=1/R= 0.172 ADJUSTED U_VALUE = 0.094 c ROOF/CEILING R @ CAVITY Y R @ RAFTER 0.170 0.170 OUTSIDE AIRFILM 0.450 1/2" GYPSUM BOARD 0.450 3.125 2x truss btm cord 2 1/2" SOFTWOOD -- FIBERGLASS INSULATION 19.U0C INSIDE AIRFILM 0.610 0.610 --- ~----- T R TOTALS -CEILING = 20.230 4.355 U=1/R = 0.049 U=1/R 0..230 ADJUSTED U-VALUE = 0.067 } AREA SUMMARY: --'---------- .. TOTAL... FLOOR CAVITY AREA' T,ryL`3r F'I;OOa FF.P�I.xly AREA: TOTAL WALL CAVITY AREA TOTAL WALL FRAMING AREA:. TOTAL WALL GLASS .AREA: . TOTAL DOOR (A) AREA, TOTAL DOOR (B)AREA: TOTAL .GLASS .AREA' 336.096 SQ, FT 37.344. SQ. FT.. 516.2.45 SO. FT. 104,808 SQ. FT. 17.667 SQ. FT. 60.000 :SQ. FT- 0.000 :SQ. FT. 17.667 SQ. FT. APPROVED BY IN[Ii,N Y THE PERCENT OF GLASS IS: TOTAL CEILING CAVITY .AREA 2.520 .526 % y TOTAL CEILING FRAMING AREA: 33Q. FT. 37.344 SQ. FT. COMBINED GROSS FLOOR THERMAL TRANSMITTANCE VALUE (UO) CALCULATIONS FLOOR COMPONENT AREA. * _ U-:VALUE = A*U FLOOR CAVITY 336.096 --- 0.077 25.911 FLOOR FRAMING 37.344 -------- 0.091 3.385 TOTAL = 373.440 ------- A--- TOTAL ='29.295 A*u Uo FLOOR = ___-- 0078 BTu/h or [ A COMBINED GROSS WALL THERMAL TRANSMITTANCE VALUE WALL (.00) CALCULATIONS AREA * -------------- U-VALUE - * , A U GLA55 17.667 1.130 19.963 DOOR (A)(1.5" METAL U=.54) 60.000 0.540 DOOR (H) GLASS 32.400 0.000 WALL CAVITY 1-.130 -0,000 516.245 WALL FRAMING 0080 41.465 104.808 -------- 0.172 17,993 TOTALS: 698.720 -------- 111.822" . A*U Uo WALL 0.160 BTU/h ^OF A.' COMBINED ROOF/CEILING THERMAL TRANSMITTANCE VALUE (Uo) CALCULATIONS ROOF/CEILING COMPONENT AREA * U-VALUE A*U -------- ROOF/CEILING CAVITY 336.096. 0.049 6-614 ROOF/CEILING FRAMING 3718,575 .344 0.230 8,575 - 0 ----- --- ----------- TOTALS; 25,189 A*U UO ROOF = ----- = 0.067 BTU/h ^oF A TOTAL ENVELOPE CONFORMANCE ZONE 1 GROSS TOTALS AREA A*U FLOOR 373.440 29.295 WALL 698.720 111..1822 ROOF 373.440 25.189 ACTUAL TOTAL 166.306 A*Uo Zane 1 Zone 2 Zane 3 Zone 4 Zone 5 FLOOR.. 39.211 41.825 31.742 30.249 28.755 Z O 6-. Zone 7 WALL 163.500 173,283 132.058 128.564 122.276 27.261 17.925 ROOF 28.755 28.008 24.647 25.394 118,084 88.039 24.647 26.141 20.539 231.467 243.11584 188:44752 184.20704 175.47792 17P.4856 OK OK DK OR. _.. 126.503 i OK OK. DOSN'T MEET CODE IF THE GRAND TOTAL (1) OF THE WALL, ROOF/CEILING AND FLOOR_.. ._ ... _..... A/R- VALt-ES IS -EQUAL TO OR LESS THAN THE TOTAL: (2) OF THE .. A x UO CODE LIMITS FOR THE WALL, ROOF/CEILING AND FLOOR, THE TOTAL ENVELOPE MEETS THE CODE, EVEN THOUGH TEE WALL, ROOF/ CEILING .OR.FLOOkt MAY NOT. IF THE TOTAL ENVELOPE CALCULATION INDICATES THAT THE DESIRED CONSTRUCTION .DOES NOT MEET CODE REQUIREMENTS,: MARE CHANGES /� n A P P ROVED BY IN[FliN MAY12 � * IN THE STRUCTURE TO ADD INSULATION, REDUCE GLASS AREAS OR USE INSULATING GLASS AS REQUIRED TO MEET THE CODE REQUIREMENTS. HEAT LOSS CALCULATIONS AREA * U VALUE * DESIGN HEAT LOSS ITEM TEMP BTUH FLOOR 373.44 0.078 WALLS 621.05 0.094 WINDOWS 17.67 1.130 DOOR (A) 60.00 0.480 DOOR (B) 0.00 1.130 ROOF 373.44 0.067 VENTILATIONCFHr 5650.00 0.018 INFILTRATION 0.00 0.018 **NOTE: INFILTRATION ADJUSTED FOR MECH VENTILATION VENTILATIO.EXLone 1 Zone 2 Zone 3: Zone 4. Zone 5. Z O.N.E 6 Zone 7 HEAT LOSS HEAT LOSS HEAT LOSS HEAT LOSS BEAT LOSS HEAT LOSS HEAT LOSS ITEM BTUH BTUH BTUH BTUH BTUH BTUH BTUH FLOOR 1289.00 1376.88 1552.,65 1611.25 1494,06 1728.43 1992.08 WALLS 2569.34 2744.52 3094.88 3211.67 2978.10 3445.25 3970.79 WINDOWS 878.39 938.28 1058.06 1097.98 1018.13 1177.84 1357.51 DOOR (A) 1267.20 1353.60 1526.40 1584.00 1468.80 1699.20 1958.40 DOOR (B). 0.00" 0.00 0.00 0.00 0.00 0.00 0.00 ROOF 1108.3-0 1103.87 1335.00 1385.38 1284.62 1486.13 1712.B3 VENTILATION CFHr* 4633.20 4949.10, 5580.90 5791..50 5370.30 6212.70 7160.40 INFILTRATION 0.00 0.00 0.00" 0.00 0.00 0.00 0.00 TOTAL (BTHU)= 11745.423 12546.247 14147.896 14681.779 13614.0131 1 15749.54 118152.018 KW ELECTRIC HEAT 3.44 3.68 4.15 4.31 -3.99_j 4.62 1 5.32 * If the ventulation is switched then CFHr * 0.5 ARE WINDOWS EQUIPPED W/ VENETIAN BLINDS? NO LIGHT OTTV CALCULATIONS (Uw X Aw X TDeq} + (Af X SF X SC) + (Uf X Af X delta I) OTTV=-------------------------------- ----- .--------------- ----- Ao OTTV = 8.80 #N/A #N/A ALLOWABLE OTTV HEAT GAIN CALCULATIONS INSIDE DESIGN: TEMP: 78 OUTDOOR DESIGN TEMP: 91 DESIGN WET BULB TEMP: 66. BEAT HEAT DIMENSION UOR - GAIN.. DELTA. GAIN STEM OR AREA MULT. FACTOR T ETD BTUH DOORS (A) 60�.00 --- 11 --- --- 660 DOORS (B) 0.:GD --_. 77 --- ---. 0 WINDOWS 17.67 --- 77 --- --- 1,520 WALL- 621.05 0.168 --- --- 18.6 1,945 FLOOR 373.44 O.25 --- --- 10 465 ROOF 373.44 0.062 --- --- 39 902 OCCUPANT --- 4 300 --- -- 1,200 LIGHTING --- 480 4.25 --- ---- 2,040 VENTILATION -- 0.018 5850 13 --- 1,369 INFILT. 87.34 0.35 --- 13 --- 397 MISC. --- --- --- --- --- 0 SENSIBLE HEAT GAIN: 10,499 BTUH LATENT HEAT GAIN: 2,100 BTUH ` OUTSIDE AMBIENT CORRECTION: 105 BTUH --- - TOTAL HEAT GAIN: 14,609 BTUH COOLING NEEDED: 1.22 TONS APPROVED BY 00or ON 11iN -a SAY 12 am ' I . MECHANICAL NOTES: NCBC VOL. III 1996 ED. W! 9€i, 97,98 NOTES: NCBC VOL.1-1996 ED. W/96, 97,98 & 99 REVISIONS ELECTRICAL NOTES. NBC VOL. fVNEC-19991D. o ACCESSIBILITY NOTES: NCBC VOL. I-C 1991 ED. W/1997 REVISIONS rGENERAL& .,9 REVISIONSL V, FIRE RESISTANCE-1996W/ 96,97,98,99 REVISIONS W/1999 REVISIONS VOLJ� ENERGY-1 996W/ 97,98 REVISIONS 7 ALL CIRCUITS AND EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH THE 1 _ THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN SHALL BE MPLAYF-D AT ALL 1 ACCESS TO BUILDING FOR PERSONS IN WHEELCHAIRS L5 DESIGNED BY AND FEW BUILT QQ 1. EXHAST FANS AND VENTING EQUIPMENT TO BE DUCTED TO EXTERIOR AND TO LOCAL JURISDICTION. THE PRIMARY ENTRANCE MUST APPROPRIATE ARTIC,LE5 OF THE NATIONAL ELECTRICAL CODE (NEC}. QLN ACCESSIBLE RESTROOM FACILITIES AND AT ACCESSIBLE B111LD11 ENTRANCES UNLESS ALL BY OTHERS AND SUBJECT APPROVED VENT CAP. . BE ACCESSIBLE.. 2. WHEN LIGHTFIXTURESFIXTURES ARE INSTALLED IN CLOSETS THEY SHALL BE SURFACE TERNNATE AT AN ENTRANCES ARE ACCESSIBLE. INACCESSIBLE ENTRANCES SHALL HAVE DIRECTIONAL SIGNS _ FOR MECHANICAL VENTILATION, USE 75% OF RECIRCULATED AIR VIA INDICATING THE ROUTE TO THE NEAREST ACCESSIBLE ENTRANCE. 2. ALL DOORS SHALL BE"OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A MOUNTED OR RECESSED. INCANDESCENT FIXTURES SHALL HAVE COMPLETELY HVAC UNIT ENCLOSED LAMPS. SURFACE MATED INCANDESCENT FDCTURES SHALL HAVE 2. ACCESSIBLE DRINKING FOUNTAINS SMALL HAVE A SPOUT HEIGHT NO HHCG-ER THAN 36 INCF-IES���, KEY TOOL, SPECIAL KNOWLEDGE OR EFFORT. MANUALLY OFFRATED FLUSH BOLTS 3. DUCT EXI)OSED TO NON -CONDITIONED SPACES SHALL 1'3E INSULATED TO ACE BOLTS SHALL NOT BY USED, A MINIMUM CLEARANCE OF 12 INCHES AND ALL (TIMER FpUTIlRIcS SHALL HAVE ABOVE THE FLOOR .AND EDGE � BASIN NO HIGHER THAN 34 INCHES ABOVE THE FLOOR HaLTR OR SURFACE F PROVIDE A THERMAL RESISTANCE ALL GLAZING WITHIN 24 INCH ARC OF DOORS, WHOSE BOTTOM EDGE IS LESS MINIMUM CLEARANCE OF 6 INCHES FROM 'STORAGE AREA` AS DEFINED BY MADE D E FOR I WHEELCHAIRS. SALLY, DRINKING BE WATER PROVISIONS SHALL U3f LAJ 3. �t. ALA. SUPPLY AIR REGISTERS SHALL BE 6 INCHES JC 10 INCHES ADJUSTABLE MADE FOR IN�5 WI.10 HAVE LTI�FNCII_T1` IN BENDING THAN 60 INCHES ABOVE THE FLOOR, AND ALL GLAZING IN DOORS SHALL BE NEC 410-8(a). NTH 8 INCHES X 18 INCHES INSIDE OVERHEAD FIBERGLASS _ 3. HVAC EQUIPMENT SHALL BE PROVIDED WITH READILY ACCESS113LE DISCONNECTS (INSIDE)PACTS 3. WHERE STORAGE FACILITIES SUCH AS CABINETS, SHELVES, CLOSETS AND DRAWERS ARE 11. SAFETY, TEMPERER OR ACRYLIC PLASTIC SHE AL]JACENT TO THE EQUIPMENT SERVED. A UNIT SWITCH WNTH A MARKED DUCT, UNLESS OTHERWISE SPECIFIED. TJUCTS IN UNCONDITIONED S PROVIDED AT LEAST ONE OF EACH TYPE PROVIDED SHALL CONTAIN STORAGE SPACE 4. FLOOR JDESIGN LIVE LOAD -50 PSF. SHALLHAVE R-5 MINIMUM INSULATION E)CEPT DUCTS EXPOSED TO POSITION THAT IS A PART OF THE HVAC: E AND DISCONNECTS ALL COMPLYING WITH THE FOLLOWINGS DOORS ETC. TO SUCH SPACES SHALL BE ACCESSIBLE 09 5. MAXIMUM WIND SPEED 70 MPH FOR ELEVATIONS OF 270G} OR LESS VENTILATED ATTICS AND CRAWL SPACES SHALL HAVE R-6.5 INSULATION- SEISMIC PERFORMANCE CATEGCI Y - C AV-- .10 UNGROUNDED CONDUCTORS SHALL BE PERMITTED AS THE DISCONNECTING 1 Cie. TOUCH LATCHES, U-SHAPED PULLS); SO;% S SHALL 1E WI HIN 15 INCHES MINIMUM ND 6. ALL DUCT MATERIAL SHALL BE CLASS OCCUPANCY IS BUSINESS MEANS WHERE OTHER DISCONNECTING MEANS ARE ALSO PROVIDED BY A 48 INCHES MAXIMUM OF THE FLOOR FOR FORWARD REACH OR 15 INCHES MINIMUM AN 7. R 5. INTERIOR DOORS SHALL BE UNDERCUT 1.5 INCHES ABOVE FINISHED FLOOR INCHES MA)"1K OF THE FLOOR FOR SIDE REACH; CLOTHES RODS SHALL BE A MAXIMUM OF 8 OCCUPANT LOAD IS BASED ON 1 PERSON PER 100 SQUARE FEET OF FLOOR AREA. READILY ACCESSIBLE CIRCUIT BREAKER- FOR AIR RETURN.UNLESS OTHER MEANS OF RETURN All ARE PROVIDED FLOOR PLAIN SHALL BE 1.51NCH X 30 GA WITH 4. PRIOR TO ENERGIZING THE ELECTRICAL SYSTEM THE INTERRUPTING RATING 54 INCHES EEDS 1THE FLOOR {48 INCHES MAX�RIIN WHEN DISTANCE FROM WHEELCHAIR 9. ALL STEEL STRAPS REFERENCED ON FL EXCEPT AT RESTROOM DOORS- OF STRAP OR OF THE MAIN BREAKER MUST HE DESIGNED AND VERIFIED AS BEING IN COMPLIANCE O ROD EXCEEDS 10 RS, R 5). 7 16 GA. X 7/16 INCH CROWN X 1 INCH STAPLES EACH END fi_ HVRC EQUIPMENT SHALL. BE EQUIPPED WITH OUTSIDE FRESH AIR INTAKES EQUIVALENT FROM RIDGE BEAM TO COLUMN AND COLUMN TO FLOOR WITH SECTION 110-9 OF THE NEC BY LOCAL ELECTRICAL CONSULTANT_ Q 4. +CONTROLS, DISPENSERS, RECEPTACLES AND OTHER OPERABLE ECI�UIP R 54 SHALL BE NO EQLIV PROVIDING 2O CFM FtNr EACH CUPANT. 10. THIS BUILDING HAS NOT BEEN DESIGNED FOR COASTAL HAZARD AREAS, OCEAN 5. THE MAIN ELECTRICAL PANEL AND FEEDERS ARE DESIGNED BY OTHERS, SITE HITCHER THAN 45 INCHES ABOVE THE FLOOR FOR FRONT APPROACH OR 54 INCHES ABOVE HAZARD OR REGULATORY FLOOD PLAIN AREAS. INSTALLED AND SUBJECT TO LOCAL JURISDICTION APPROVAL. THE FLOOR FOR SIDE APPROACH. RECEPTACLES ON WALLS SHALL BE MOUNTED NO LESS 11, CONSTRUCTION IS TYPE VI UNPROTECTED. 6. ALL QRCUJIfS CRU6SINCy OVER MODULE MATING LINE(S) SHALL BE SITE THAN 15 INCHES ABOVE THE FLOOR. EXCEPTION: HEIGHT LIMITATIONS TATIONVS DO NCTI APPLY WHERE 12. MINIMUM CORRIDOR WIDTH( IS 44 f 4CHES» CONNECTED WITH APPROVED ACCESSIBLE JUNCTION BOXES OR CABLE CONNECTORS_ THE USE OF SPECIAL EQUIPMENT DICTATES OTHERWISE OR WHERE ELECTRICAL RECEPTACLES 13. MINIMUM CORRIDOR FINISH IS CLASS B (GYPSUM)- 7. WHEN WATER HEATERS ARE INSTALLED THEY SHALL IE PROXVIIED WITH READILY ARE NOT NORMALLY INTENDED FOR USE BY BUILDING OCCUPANTS. 14. DELETED ACCESSIBLE DISCONNECTS ADJACENT TO THE WATER HEATERS SERVED_ THE S. WHERE EMERGENCY WARNING SYSTEMS ARE PROVIDED, THEY SHALL INCLUDE BOTH AUDIBLE 2 e - 15. FIRE "PROTECTIVE SGFNALING SYSTEMS) PER NFPA-72, AND FIRE DETECTION SYSTEMS) EfRAN[J I CIRCUIT SWITCH OR CIRCUIT BREAKER SHALL BE PERMITTED TiD SERVE AS AND VISUAL ALARMS. THE VISUALALARMSSHALL BE LOCATED THROUGHOUT. INCLUDING '� SHALL BE DESIGNED AND SITE INSTALLED BY OTHERS SUBJECT TO LOCAL JURISDICTION THE DISCONNECTING MANS ONLY WHERE THE SWITCH OR CIRCUIT BREAKER IS RESTROOMS, AND PLACED 80 INCHES ABOVE THE FLOOR OR 6 INCHES BELOW CEILING, APPROVAL. WFM IN SIGHT FROM THE WATER HEATER OR IS CAPABLE OF BEING LOCKED IN THE WHICHEVER IS LOWER. 16 IF REQUIRED RESTRDOM FACILITIES WILL BE PROVIDED ON SITE IN AN ADJACENT OPEN POSITION. 6. DOORS TO ALL ACCESSIBLE SPACES SHALL HAVE ACCESSIBLE HARDWARE (i.e. LEVER - OPERATED, BUILDING WITHIN A TRAVEL DISTANCE OF 200 FEETSUBJECT TO LOCAL INSPECTION, 8. EXTERIOR LIGHTING NOT INTENDED FOR 24 HOUR USE SHALL BE AUTOMATICALLY PUSH -TYPE, BE ST STABLE MOUNTED 30 INCHES TO 42 INCHES ABOVE THE FLOOR. THIS SHALL BE NOTED ON THE BUILDING DATA PLATE_ SWITCHED BY EITHER A TIMER OR PHOTOCELL- 7. FLOOR SURFACES SHALL BE STABLE FIRM, AND SLIP -RESISTANT. CHANGES IN LEVEL 9. ANY SITE INATALLED ELECTRICAL EQUIPMENT DESIGNED} AND INSTALLED BY OTHERS BETWEEN 0.25 ITCH AND 0.5 INCH MALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2_ SUBJECT TO LOCAL JURISDICTIC)N APPROVAL. CHANGES IN LEVEL GREATER THAN 0.5 INCH REQUIRE RAMPS. CARPET PILE THICK NI"SS 10. ALL HEATING ELEMENTS NOTED MORE THAN 48 AMPERES SHALL HAVE THE HEATING SHALL BE 0.5 INCH MAX_ GRATINGS IN FLOOR SHALL HAVE SPACES NO GREATER THAN 0.5 ELEMENTS SUBDIVIDED 90 THAT EACH SUBDIVIDED LOAD SHALL NOT EXCEED 48 INCH WIDE IN ONE DIRECTION: DOORWAY THRESHOLD SHALL NOT EXCEED 0 5 INCH IN HEIGHT. AMPERES AND SHALL BE PROTECTED AT NOT MORE THAN 60 AMPERES. THIS 8. ACCESSIBLE WATER CLOSETS SHALL BE 17 INCITES TO 19 INCHES FROM THE FLOOR TO THE TOP OF THE SEAT; GRAB BARS SHALL BE 36 INCHES TONG MINI PROTECTION CAN BE INSTALLED INTEGRAL TO THE EQUIPMENT BY HVAC EQUIPMENT MINIMUM WHEN LOCATED BEHIND ' MANUFACTURER OR PLANT INSTALLED AS FEEDER PROTECTION. WATER CLOSET AND 42 INCHES MINIMUM WHEN LOCATED ALONG SIDE OF WATER CLOSET, AND SHALL BE MOUNTED 33 INCHES TO 36 INCHES ABC VE THE FLOOR SI)EWALL GRAB BARS SHALL BE MOUNTED WITH THE FAR END LOCATED`A MAXIMUM OF 12 INCHES FROM THE WALL BEHIND WATER CLOSET. 9. ACCESSIBLE URINALS SHALL BE STALL -TYPE OR WALL HUNG WITH ELONGATED RIMS AT A . MAXIMUM HEIGHT OF 17" ABOVE FINISHED FLOOR AND 14' FROM THE WALL. 10. ACCESSIBLE LAVATORIES SHALL BE MOUNTED WTEH THE RIM NO "C3HER THAN 34 INCHES ABOVE THE FLOOR AND A CLEARANCE OF AT LEAST 29 INCHES ABOVE THE FLOOR TO THE BOTTOM OF THE APRON. SYMBOLS 11. ACCESSIBLE SINKS SHALL BE MOUNTED NTED WITH THE RIM NO HIGHER THAN 34 INCHES ABOVE THE FLUOR AND A CLEARANCE OF AT LEAST 27 INCHES HIGH, 30 INCHES WIDE AND 19 INCHES DEEP ELECTRICAL SCHEDULE "A" UNDERNEATH SINK THE SINK DEPTH SHALL BE 6.5 INCHES MIAXiMUMT ELE 12. HOT WATER AND DRAIN PIPES UNDER ACCESSIBLE LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. INSULATION OR PROTECTION DUREXRECEPT ?o V. NOMENCLATURE BREAKER WIRE MATERIAL MAY SITE INSTALLED THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER flh CIRCUIT AMPS) COOL) ACCESSIBLE LAVATORIES AND SINKS. THE MPJOMNJM WATER TEMPERATURE TO WATER OUTLETS SERVING HANDICAPPED FIXTURES SHALL NOT EXCEED 120° F_ { SINGLE REGEPT 240 V. 1 A,3A HVAC 30A (2P) 10 -2W/'1 13. ACCESSIBLE LAVATORIES AND SINKS SHALL HAVE ACCESSIBLE FAUCETS Cie. LEVER OPERATED, PUSH -TYPE, ELEC:TRONICALLYCON ROLLED). � INCANDESCENT LIGHT'W/ 14. WHERE MIRRORS ARE PROVIDED IN RESTROOM AT LEAST ONE SHALL BE PROVIDHD WITH ITS 1 - 60 WATT BULB 2A EEMAX @ 3.5 KIN 30 A 1 P 10-2 N BOTTOM EDGE NO HIGHER THAN 40 INCHES ABOVE THE FLOOR. ' LIGHTING 15. WHERE MEDICINE CABINETS ARE PROVIDED, AT LEAST ONE SHALL BE LOCATED WITH A USABLE E)UHIAUST FAN 4A,5A;6A ,RECEPTACLES 15 A T 4-2 NM SHELF NO HiGHFER THAN 44 INCHES ABOVE THE FLOOR. 16. GRAB BARS REQUIRED FOR ACCESSIBILITY SHALL BE 1.5 INCHES IN DIAMETER WITH 1.5 INCHES 3' VTR CLEAR SPACE BETWEEN THE 13AR AND THE WALL. 1 ° eaM��uvE� F�� i�:l ;�T .-- APPROOVIED", SLOPPILY AIR k�GIS' �-R < RETURN AIR I&GDSTER FOR t PERMIT 3 FIRE ALJ4Rw PULL STATION ELECTRICAL PANEL SIZING FIRE ALARM HORN FIRE ALARM STROBE LIGHT' DESCRIPTION PANEL . A" KVA THERMOSTAT e LAV FLUORESCENT FIXTURE GENERAL IJGHTING p W/ 2 - 40 WATT TUBES .0035 KW/SF X 373.3 SF X 1.25 = 1.6 ' 3� DOT SIGN 7- RfC`EPTS AT 180VA/1000 1.3 1-EEMAX0 3.5KW= 3.5 JUNCTION BN1x 1 -FANS AT .3 KW X 1.25 = . PLUMBING NOTES: NCBC - VOL. 111996 ED. 1 112E Q 1-HVRC� 6.5 W/ 1996, 1997, 1998 & 1999 REVISIONS VF TELEPHONE JACK TOTAL = 13.3 KW 1. TOILETS SHALL BE ELONGATED WITH NON -ABSORBENT OPEN FRONT SEATS. WC 3 TOTAL/240 X 1000 =55.3AMPS 2. RESTROOM WALLS SHALL BE COVERED WITH NON -ABSORBENT MATERIAL TO A MINIMUM HEIGHT EMERGENCY LIGHT Wl INSTALL 100 AMP PANEL OF 48 INCHES AFF. i BATTERY BACKUP 120/240 V., 5(E'PHi. 3. CUSTOMER ASSUMES ALL RESPONSIBILITY FOR DRINKM WATER FACILITIES AND SERVICE SINK WHEN NOT SHOWN ON FLOOR PLAN TO BE SITE INSTALLED AND SUBJECT ; E' �, TO LOCAL JURISDICTION APROVAL t✓ V FLOOD LIGHT 4. ALL PLUMBING FIXTURES SHALL HAVE; SEPARATE SHUT-OFF VALVES 3 5. w 6. WATER PIPES INSTALLED IN A WALL EXPOSED TO THE EXTERIOR SHALL BE LOCATED ON THE SWITCH ELECTRICAL SCHEDULE "B HEATED SIDE OF THE WALL INStILATICON_ WATER PANG INSTALLED IN AN UNCONDITIONED SPACE SHALL BE INSULATED WITH AN INSULATION OF R 6.5 MINIMUM. . DWVRISERS 7. DWV SYSTEM SHALL BE EITHER ABS OR PVC-DWV. NTS L.AV 3-WHY SWITCH BREAKER WIRE 8_WATER SUPPLY LINES SHALL BE CPVCflRCOPPER; ` � 3 CIRCUIT NOMENCLATURE (AMPS) (CU_) 9. WATER CLOSETS ARE TANK TYPE AND URINALS ARE FLUSH TANK TYPE UNLESS OTHERWISE . SPECIFIED. HVAC 1 O'.BUILDING DRAIN AND C�.EAINOUT9 ARE DESIGNED AND SITE INSTALLED 6Y OTHERS SUBJECT WC 3/4 RISER RECESSED FLOURESCENT TO LOCAL JURISDICTION APPROVAL 2 440 IXTUUE Wl 2--40 WATT 11 -LAVATORIES 1N PUBLIC RESTROOMS OF EDUCATIONAL OCCUPANCIES, ASSEMBLY OCC UPAWOES IR 4/40 VWkTT BULBS AND ALL OTHER OCCUPANCIES CONTAINING RESTROOMS WHICH HAVE 6 OR MORE LAVATORIES LIGHTING SHALL BE EQUIPPED WITH A FOCTT SWITCH, OCC JP'ANT SENSOR, OR SIMILAR DEVICE, OR IN rfl OTHER THAN AN LAVATORIES FOR THE PHISICALLY HANDICAPPED, LIW HOT WATER TO OLS EEMAX L03.514W & RECEPTACLES GALLONS PER CYCLE APPROVED BY MA°,. r £, 3141NLET NOTICE WA APPROVAL IS NOT VALD IN HOST PORTIONS OF LISTEDSTATE(S) WHERE SUNSHINE MANUFACTURED STRUCTRUESJNC. SNOW LOADS DETERMINED FROM LOCAL ELECTRICAL PANEL SIZING: METEORLOGICAL DATA EXCEED THE 850 GOLD HILL AVE.; ROCK;WELL� INC 28138 LISTED LIVE LOAD. TELE 704-279-6600, FAX: 704-279-77749 DESCRIPTION PANEL „ B„ KVA DATE`_ 5-11-99 THIRD PARTY: NTA INf iAPPAH� N.D46 S5 0 CODES: SEE NOTES y LABELS NTA N_C REVISIONS. BY: SUPP FYR IRS CSH , • � SCALE: NTS SUPPLY LINE SIZING ISBASED ON AN COLDSUPPLYLINES ASSUMEMAVAILABLE PRESSURE OF ry -7 �,r T 46 - i60 PSI AT MAIN INLET AND SERIAL F02 � 47 l 4 1 2X3 2 J HOB' SUPPLY LIMES - - - -- - .- SHOULD BE VERIFIED PRIOR TO ALL SUPPLY LIIEsa/a- UNLESSTHERVVISE N4T CONSTRUCTION_ 'I OF 4 ALL SUPPLY RISERS 112- UNLESS OTHERWISE NOTED COVER SHEET INLET LOCATION MAY VARY , FRAME AND FLUOR WALLS EXTERIOR ELECTRICAL HVAC PLUMBING DESIGN SPECS AXLES: [I ] BRAD, [ 1 ] IDLER HEIGHT: 8'-0" EXT. INSULATION: R-11 K SHEATHING! TYVEK FULL WRAP PANEL BOX: [ 11100AMP" PHASE-- SGL [I ] 1 TON A/C WATER HEATER: [ 113.5 EEMAX BEAM: 10" STUDS AND PLATES: 2x4016"OC SIDING: HARDIPANEL LIGHTS: [6] RECESSED 240 BARD WA121—A05 OR EQUPI COWME-' 11lH/e HfI•CH: [ 11 REM COVER: 1 /2" VINYL COVERED GYP TRIM: WOOD HEAT STRIPS: 5 KW FRAME: OUTRIGGERS 4'-0" INT. DOORS: REFER TO DOOR SCHEDULE ROOF EXIT SIGNS. [2] NON -LIT SUPPLY: O/H LAVATORY [1 ]WALL MOUNT ROOF TYPE: PEAK TRUSS: LLC#304 RETURN -STD WALL GRILLE APPLY: STD WASTE: PVC N PERM: &JOISTS: 2X$�16 OC WINDOWS-- [2] 24x53 V/S B✓C N SHEATHING: 7f16 OSB RECEP"I5: [7] SWITCHES' [3] 6X10 DIFFUSERS: [4] T.P. HOLDER: [1 ] MIRROR: [1 I DECKING: 5/80 T&G COVER: SHINGLES GRAB BARS: [ 1 ]42" & [ 1 ]36" DESTINATION: BUNCOMBE CO. COVER: 1/8 BLK TILE EXT. DOORS: REFER TO DOOR SCHEDULE CEILING MATERIAL: SEASP'RAY POWER VENTS: [11100 CFM COMBO WIND: 7OMPH TIE DOWNS: STD INSULATION: R-19K FLOOR: 50PSF (1 OPSF DL) MOULDING: STD PART. INSULATION: R-1 ISOUND OVERHANG: 6" ALL SIDES ROOF: 30PSF (1 OPSF DL) INSULATION: R-11 OCCUPANT LOAD: 4 24x53 V/S B/C [m' 21 o Q I 1 OOAMP PANEL" A" 120/240V, SGL PH i r-------- _ — ---- — -----� -- -- ---- I A 1 TON HVAC W/ 5 KW HEAT STRIPS,390CFM 0 .31WC ESP F)PROVED. - 24OV, SGL PH. PROVIDED WI FRESH AIR INTAKE. 14X24 R/A GRILLE. I NAT FOR cv VTR 7 Y Y I's a _ l �. _.-.. _---- cc r ,- X 3AJNlT S - 1''i. Y E� A, sp 6X7 0 STD OFFICE 36"#4} I�4V- SUPPLY [TYP 41 OFFICE , 42" GB NEU s. T 7. T E�MAX: 30 AMP DEDCKT //L 3.sKW, - .�P"f� r� APPE�UED BY ,32,-O" 12OV, S POHZ, v A� , o e"m �{ -INR Na DOOR SCHEDULE [1 172x80 STL/WD W/10N V.B. FOOT & HEAE BOLT, EXT CLOSER, SURFACIz MOUNTS PANIC HARDWARE W/VERTICLE ROD [11 36X80 STL/WD W/10" V.B., EXT CLOSER, SURFACE MOUNTED PANIC HARDWARE W/VERTICLE ROC} [11 36x80 1 3/8" STD H/C W/PASSA4 - LEVER [I 136X80 1 3/8" STD H/C W/PRIVA CY LOCATION OF GROUND ANCHOR NOTE: ALL DEPARTMENTS MUST SIGN & DATE` LEVER STRAP CONNECTION TO COLUMN COLUMN STRAPPING SCHEDULE SECTION REVIEINAL OF PRKIr SIGNATURE E (LEAD MAN) DATE SUNSHINE MANUFACTURED STRUCTURES, INC 850 GOLD HILL AVE.; ROCKWIELL,- NC 28138 (2) 2X4 SPF #2 THIS HALF (2) 2X4 SPF #2 EACH HALF PURCHASINGTELE NO.: (704)279-6600 FAX NO.: (704)279474 C (3) 2X4 SPF #2 THIS HALF (3) 2X4 SPF #2 EACH HALF (4) 2X4 SPF #2 THIS HALF (4) 2X4 SPF #2 EACH HALF FRAMES FLOORS DATE: 03-3 I —99 THRID PARTY: NTA INC. 305 N_ OAKLAND A . CODES: NC BUSINESS NAPPANEE, IN 4655 SIDEWALLS LABELS: NC REVISIONS: [1105-05- Y: BDJ C (5) 2X4 SPF #2 THIS HALF (5) 2X4 SPF #2 EACH HALF ELECTRICAL SCALE: 1 /4" 1. ALL COLUMN STUDS SHALL BE GLUE/NALED TOGETHER, PVA CLUE WITH 100% CEILINGS SHEET COVERAGE SHALL BE USED. 2. INSTALL TWO 3' x W MIN. STEEL STRAPS AT EACH COLUMN, FASTENED W/(12) SIDING SERIAL #: F 0 2 3 6 47 7 4 12 X 32 16 GA x 7/16" CROWN x 1' STAPLES AT EACH END OF STRAPS. TOPS 3. COLUMN STUDS SHALL NOT 6E NOTCHED OR BORED. 2 OFS._MiATELINE 4. RIDGEBEAM STIFFENERS REQUIRED AT ALL COLUMN LOCATIONS. FINISH /� FLOO'RPLAN OPENINGS UP TO 36", FRAMED IN ACCORDANCE WITH EOITERIOR WALL REQUIREMENT IN APPROVED CONSTRUCTION MANUAL. SFI� LOOSE d 32'-0° S' D 0' REFERENCE POINT ....... — --- , ----- - e---- e r r � e PIER TYPE "A— HITCH END TYPICAL UNDER ALL I —BEAMS { UNLESS OTHERWISE SPECIFIED 44-4- --� - -, .__. ——--� ----- - --- e , , e ' e : F1 F1 e: e � r 11 - - - - .- _e e - - - - yI .. . . r e -.- _ - r e.— — —.— — a NOTE: THIS FOUNDATION PLAN IS PROVIDED FOR REFERENCE AS A TYPICAL STANDARD. ACTUAL. FOUNDATION CONDITIONS MUST BE EVALUATED FOR APPLICABILITY IF THIS PLAN IS TO BE USED. ALTERNATE FOUNDATION PLANS MAYBE DESIGNED BY OTHERS IN ACCORDANCE WITH THE JURISDICTION HAVING AUTHORITY. I I; APPROVED BY `� M14Y 1 2 IOR SIDEM/ALL SOL:IDS'X24"z24' FOUNDATION DINENWNS CONCRETE FOIJfING A A WIDTFI MODULE EDGE SPACING FRAME TIE—DOVVN STRAP AND GROUND ANCHOR AT 14'-5- O.C. MAX (TYP.) 11'-8" 32-1/4" 75-112" FINISH GRADE MINIMUM SOIL �, MAXIMUM PIER 110. �-W�IMND PLAN VIEW SECTION SPACING BEARING CAPACITY wt ANCFIOIt FOOTINGS MUST DCIEND SECTION A -A PIER TYPE Q1 10'-0' 20(O0 PSF BELOW FROST LIIF 1O'-0' 3000 PSF FOUNDATION NOTES: r1ALL SUNSHINE MANUFACTURED STRUCTURES, INC. FOUNDATION CONS! MATERIALS ANDINSTALLATI ON SHALL E IN ACCORDANCE WITH ALL AP�B.:K:ABLE STATE AND LOCAL 4. THE FIRST TIE -DOWN STRAP FROM ENDWALL SHALL NOT E'OWEED 1/2 THE10_ MAXIMUM SPACING INDICATED. INSTALL EiLOCiC PIER ON EACH SDE OF ALL EXTERIOR DOOR OPENINGS. 850 CiOi D MLL AVE. ROCICWEL NIC Z813$ � -CODES. 2. DOWiFI STRAPS TO BE 1-1l4' X.035 TYPE-1 FINIS( GRADE-1 S. ALL PAR SHALL BE CONSTRUCTED OF 8'XS'OC16' OONCREI E MASONRY UNITS (MANf1FAOTURER'S REG�OI�IwEhIDATIOFi ONLY (OPTIONAL WHEN NOT SHOWN) ADJUSTMENT MAY TO INSURE UPENABILffY AFTER TELE : 704-219-6600 FAX :704-279-7749 zINC COATED STEEL STRAPPNG CERTIFIED BY A REGISTERED ENGINEER CONFORMING TO ASTM C90. MASONRY UNITS SHALL BE LAID IN TYPE M OR S INSTA I CX"4—E IS COhWITH COR ARCHITECT AS ODNFOR14NG WITH AST ►(-D3953-91. TIE DOWN STRAPS (MORTAR OR COVERED WITH SURFACE BONDING CEMENT INSTALLED? IN SPACE TO BE VENTILATED WITH OPENINGS THAT PROVIDE A MI#I f 1 CRAWL SPACE O E VENT( 1 5I1OVED DATE: 5-11-99 THIRD PARK: NTA INC. AND CONNECTING HARDWARE SHALL HAVE 3150# MINIMUM WORKING AOCORDANCE WITH ITS LISTING. MA)CIMUM PIER HEIG14 , MEASURED FROM _ FOOT AN APPROVED SPA ERE N FOOT OF NET AREA FOR EACH l ,��,� FEETCRAWL SPACE. O AVE. CAPACITY. THE TOP OF THE -FOOTING , SHALL BE 4 TIMES THE LEAST DIMENSION OF THE OVER THE REDNET VAPOR BARRIER IS INSTALLED OVER EACH CRAWL NET OPENING MAY CODES NCBC., NEC. NAPPANEEIN. 446S 3. GROUND ANCHORS SHALL HAVE 3150# MNIMIIM WOP60MG CAPACITY, AND HOLLOW MASONRY PIER . PIER FOOTING SHALL BE AS DESCRIBED ABOVE. 1SQ1SURFACE, . SHALL REDUCED RE FOOT FOR EACH 15CT SQUARE .FEET. CRAWL SPACE ACCESS SHALL SHALL BE INSTALLED IN ACCORDANCE VIN H THE MANUFACTURER'S 6. MINIMUM CONCRETE FOOTING CO SSIVE STRENGTH 2500 PSI AT 28 DAYS U O BEA MINIMUM COI}$* X 24'. SPECIFICATIONS. DESIGN OF GROUND ANCHOR, INCLUDING SHAFT 7. ALL REINFORCEMENT BARS SHALL 0OWPLY WITH ASTM A61 S GRADE 60. RWX'- LABELS NTA, NC. REVISIONS - BY. LE NGTH. NUMt3ER, AND DIM�ETER OF HELID�E.S ETC. TO BE AS SPECIFIED SY THE GROUND ANQIOR MANUFACTURER F0I1 THE ACTUAL SOIL TYPE REINFORCEMENT BARS SHALL BE EQUALLY SPACED AND D WITH 3- CLEARANCE FROM BOTTOM AND SIDES OF I^OOTING —NTS— CSI1 LNCOilNTERED. IF THE HOLDING OR PULLOUT CAPACITIES OF GROUND S_ (—BEAM SUPPORT PIERS MAY BE INSTALLED LATERALLY (90 DEGREES FROM SCALE ARE BELLOW THE VALUES SPEMED ABOVE, THE THE ORIENTATION SHOWN ON THE FOUNDATION PLAN). CENTERLINE OF SHEET ARCHITECT/ENGINEER MUST BE CONSULTED FOR AN ALTERNATE � DESIGN. 9. EACH PER MUST BE LOCATED DIRECTLY BELOW THE I —BEAM CENTERLINE.SHEET ALL PIERS SHALL BE CARPED WITH 4' SOUD CAP BLOCK OR 2X PRESSURE :� SERIAL_ //�� ,/ V ! X 3 OF 4 TREATED W✓ TOP BLOCK FILLED W✓ MORTAR. FOUNDATLON PLAN ' e ���,�� �5 Y"", as•t ei}r. ,. t , 'd' ", •+ t .:. `: :,i.:Ls ,t`; FULL LENGTH FILLET WELDS ONE SIDE OF ALL FLANGES AND WEB AT ALL OUTR IGGFRS AND I O'' WIDE UNITS REQUIRE Na IllEGGERS. CR05SMEMBERS- 1 1 /2' FOR 10- & 12' WIDE oNI ENDWALL 48' INALLBEAM FOR 10 WIDE5IEWAMDFLANGE CLIP 2" FOR 14'WIDE UNITS 1 INTO JOISTS AT 16" O-C- ON OUTSIDE FLANGE OF EACH I- 12 GIt OUTRIGGERS OVERHANG CONSTRUCTION .._ __------- 3" FOR 14` WIDE UNITS WIDE UNITS 2" FOR 8` 1 O', 12' - PER P. C-23.7 FOR 10 12' ITS APPROVED CONSTRUCTMANUAL SIDEWALL 9' FOR 14' WIDE UN T5 6 STAGGIEIt JOINTS 48" O.0 SHEATHING TOBE'FASTEN ED TO TRUSSES WITH $d NAILS AT 6' O C."ON 1 1 /8 FOR EDGES AND 12' IIN FIELD t 4" WIDE UNIT LA 8% 10'• 15' WIDE UNITS VElz-t�OiR t WIDE UNITVSVIDE UNITS 32 1/4" FOR 12' WIDE UNITS ROOF SHEATHING DETAIL 1 a sIL CRaSSMEMBERS (10 BE LOCATED OPPOSITE OUTRIGGERS AS SHOWN} CROSSMEMBER SECTION OUTRIGGER SECTION I I 1.2 SQUARE FEET NET FREE AREA OF ATTIC VENTILATION ED TO BE PROVIDED BY GABLE AND/OR ROOF VENTS E PER MODULE op, PEPOIT PERMIT D�� 1 SEE MECH. NOTES FOR CEILING DUCT SPECIFICATIONS LISTED TRUSSES AT 16" OR 24` RC LISTED ROOF TRUSS DESIGN LOADS; LIVE LOAD 30 PSF TOP CHORD ROOF COVERING OVER 7/16- OW RMIED DEAD LOAD 7 PSF TOP CHORD SFTE,ATHING, MINIMUM Il 24/0 - SEE ROOT 3 RIM MEMBER 23C3 SPF #3 MEINIMU SHEATHING DETAIL. EXTERIOR WALL FINISH DEAD LOAD 7 PSF BOTTOM CHORD1 12 2 1/4 /- SEIOR ALL STRI1CiTJFtAL BRACING Ij INSTALL CONTINUOUS 2 1/2"WIDE PLYyypp BRACING INSTALIATIONt BEARING STRIP OVER TOP PLATE {TYPICAL) STRUCTURAL SHEATHING SHALL CONSIST OF A THE SAM E THICKNESS AS CEILING FINISH) 4 FOOT MINIMUM WIDTH SHEET EXTENDING STEEL NOTES ( CONTINUOUSLY FROM TOP TO BOTTOM PLATE WITH ALL SHEATHING EDGES EXTENDING 3/4- MINIMUM OVER 2" MOM INAL LUMBER OF THE t _UNLESS OTHERWISE SPECIFIED ALL j SAME SRE AND GRADE AS EXTERIOR WALL STEEL MUST COMPLY WITH ASl=1A 30 GA. X 1 1 /2- STEEL STRAP FROM FRAMING. BRACING SHALL BE LOCATED AS CLOSETRUSS TO WALL STUD 2. ALL LAG ES ROWS MUST COMPLYVAT" 7-16 GA X 1 " STAPLES�PER STRAP END CEILING INTERIOR FINISH WITH IQIAFTIiIICK B1LACIN& MA7ERIAL:MUM. ANSI/ASME B18,2,1 _ ((TYPICAL SI - )) WIll TH INSU.AT1 TO 25'EACH CORNER OF BUILDING AS P0551I'ILE �i NOTE: TRUSSES W 1& DOMM FALL 1 /8 STRUCTURAL RED TFERMO-PLY FASTENED APPROVED DIRECTLY OV'ERWAL.L STUDS SHALL. BE DOUBLE TOP PLATE 2)(4 WITH 16 GA. X 1' X 1 1 /4' STAPLES 3' O.C. STRAPPED TO TOP PLATE AND TOP SPF #3 ON EDGES AND 5- 0.C_ IN THE FIELD OR PLATE SHALL BE STRAPPED TO EXTERIOR WALL LISTED METAL WIND BRACES LNSTA -CED PER Wk CLOSEST ADJACENT STUD WITH STUDS 2X4 STUD MANUFACTURER'S SPECIFICATIONS.OR EQUIVALENT STRAPPING) SPF USE THE SAME STRUCTURAL BRACT MATERIAL R�(� TYPICAL WINDOW SEE FLOOR 6 M e FASTENING METHOD AS SPECIFIED FOR ENDWALLS. i { `+ C I 1N rR PLAN FOR SPECIFICATIONS MODULE ENDWALLS: CRIPPLE STUDS 2X4 SPF STUD AT 16' OC '0 BRACING INSTALLATION: STRUCTURAL SHEATHING SHALL EXTEND CONTINUOUS INTERIOR FINISH MATERIAL: WITHXIQINSULATIC FROM TOP OF TRUSS TOP CHORD TO 3/4" 14INIMU14 2XHEADER PER APPROVED' STRUCTURAL PACKAGE EDGEBELS TOP OF RIM JOIST WITH ALL SHEATHING - SUPPORTED BY 2' NOMINAL CUMBER OF THE SAME Sim AND MADE AS EXTERIOR WALL FRAMING. v� /4-1.OUNITS) 1 - ROUT OFF FOSS BRACINR MATERIAL: CEILING - 1 /2' MINIMUM GYPSUM BOARD SEA51'RA I 7/16- O�SB 24/16HHITHING E'XP-1 EiIF►-�2 EXT., INSTALLED PER MANUFACTURERS SPECIFICATIONS. S/8` PLYWOOD STURD--I-FLOOR FLOOR SHEATHING ' T1►6EXP124'OC OR 7/16"OSB24/1SIDING EXT. FA�TENEDVVITH Ild COMMON OR 6AL1/. BOX NAILS 5" O.C. EDGES WALL - 1/2' MINIMUM VINYL COVERED GYPSUM BOARD ( ' y ' AND 12" O.C. IN THE FIELD OR 9S 1 2 14' 1 /a- STRUCTURAL RED TIiI RMO-PLY FASTENED WITH 16 GA. X 1 ' X 1 1 /4- STAPLES 3" G.C. EDGES BOTTOM PLATE 2XA SPF #3 AID 6- O.C. IN THE FIELD_ FLOOR - 1/8 BLOCK TILE THRU-OUT. INSTALLED PER MANUFACTURERS SPECIFICATIONS_ YWOODR-1 I INSULATION 30 CJL X 1 1 /2" STEEL STRAP'VV/ 7 -16 Gil X 1 _ STAPLES PER STRAP END FROM WALL STUD TO FLOOR JOIST AT OPENING STUDS AND �IOR FINISH MATERIAL: 16' OC FOR 90 MPH AMA ABOVE 32 OC FOR 80 AND 70 MPH (TYPICAL SIDEWALLS & ENDWALL Si ROOF - SHINGLE ROOF SOLID 4* CAP BLOCK OR INSTALLED PER MANUFACTURERS SPECIFICATIONS. F'R1:SSITFiE TREAz€D u «: OVER 2 LAYERS OF 15 # ROOFING FELT OUTRIGGER AND CROSSMEFAER 2X W/TOP BLOCK io SPACING 48" OC MAXIMUM FILLED W/ MORTAR .- ,7 s TYPICAL. I -BEAM PIER RIM JOIST ZX8 SYP Aft i 2- 5/16- X3' LAG SCREWS FASTENED THROUGH GRADE # WALL -HARDI PANEL SIDING INSTALLED PER MANUFACTURERS SPECIF CATIO'�jt5. FLANGE INTO JDIST AT EACH OUTRIGGER (TYPICAL) FLOOR JOISTS 2X8 SYP z AT 16 ac MAY BE USED AS REQUIRED BRACING 3 OUND ANCHOR i FODTING TO DaND SUNSHINE MANUFACTURED STRUCTURES, INC. 1--TEAM - Ml 2X11.8 OR Il BELOW FROST LINE (OPTIONAL. M8)(6.5 FOR MODWE 850 GOLD 'ILL AVE., ROCKWELL, NC 28138 LENGTHS NOT FJ(CEEDING 40' AAXX TELE :: 704-779-6600 FAX: 704-279-7749 DATE: 5-11-99 THIRD PARTY: MIA INC 3os N. QAKLAND AYE NAPPANIE 46550 CODES: NCBC, NEC. LABELS NTA, NC REVISIONS: Byj SCALE. —NTS F SERIAL F02364774 12x32 TYPICAL CROSS SECTION �L