Loading...
HomeMy WebLinkAboutCBPR-8-11-12051 Engineers Design Comments.tif t .,,� �aVivcci .��c i�eerih , lhc. PO Box 66 Unionville Center, OH 43077 June 28, 2011 American Tower Attn: Julia Schnell Re: Proposed 175 -ft Monopole (Fut. 195 -ft) { Located in Catawba Co., NC: Site #274746 - City of Hickory DaVinci Job # 11235 -1405 / TAPP TP -9803 Dear Ms. Schnell: We understand that there may be some concern on the part of local building officials regarding the potential for failure of the proposed communication monopole. Communication structures are designed in accordance with the Telecommunications Industry Association TIA/EIA- 222 -F, "Structural Standards for Steel Antenna Towers and Antenna Supporting Structures ". We have designed this monopole to withstand a basic wind speed of 75 mph as recommended by TIA/EIA- 222-F for Catawba County. The design also conforms to the requirements of the 2003 International Building Code. This monopole has been intentionally designed to accommodate a theoretical fall radius. The upper 101' of the pole has been designed to meet the wind loads of the design, however, the lower portion of the pole has been designed with a minimum 14% extra capacity. Assuming the pole has been fabricated according to our design and well maintained, in the event of a failure due to extreme wind and a comparable appurtenance antenna loads (winds in excess of the design wind load), it would yield at the 94' elevation, resulting in a maximum 101 fall radius. Please note, prior to extension, the pole is not subject to collapse as a result of natural structural loads (wind, seismic, etc.). DaVinci Engineering has designed the structure with all of the applicable factors as required by the code. Communication poles are safe structures with a long history of reliable operation. We hope this review of the monopole design has given you a greater degree of comfort regarding the design capacity inherent in pole structures. If you have any additional questions please call me at 614 -937- 4922. Sincerely, DAVINCI ENGINEERING, INC. ` ���rrurur rq SEAL r.- c Michael F. Plahovinsak, P.E. • ��' wlke. "avinct- ndneedne c "7141%inj CriatiVit� into Jetatity" www.davinci- enOneerine com PO Box 1966 PO Box 66,110 W. Main St. 1 Santa Maria, CA 93456 Unionville Center, OH 43077 (805)922-5221 (614)9374922 ( 't t va,Vtfi� DESIGN SPECIFICATIONS: �+�c9ivi 1viC. DESIGNED ACCORDING TOJIA /EIA -222 -F 1996 PO Box 66, Unionville Center, OH 43077 COMPLIES WITH:2009 NORTH CAROLINA BUILDING CODE %A PH: 614 - 937 - 4922 / FX: 614 - 413 - 2887 a Wind Speed Load Cases: (According to the TIA /EIA -222 -F 1996) 's 5� LOAD CASE 1: 75 MPH DESIGN WIND SPEED ! U ransG,1m������ LOAD CASE 2: 65 MPH WIND SPEED + 1/2" Power Pr ADIAL ICE I ® I guy Inc. Ine. [A" "a rw i.e. LOAD CASE 3: 50 MPH OPERATIONAL WIND SPEED - $ " pt° '' Tex 770N Pole Steel Specifications: PH: 281-444 -8277 FX: 281- 444 -7270 POLE SHAFT SHAPE: 18 -Sided Tapered Pol on ti POLE SHAFT TAPER: 0.20513 inches ft. POLE SHAFT STEEL: ASTM A572 GR. 65 (F = 65 KSI) _ BASE PLATE STEEL: M A 195'_0" TOP POLE ti s Y� K I 3 - �'uf�iJ' 3/16' PLATE x 20.00' LONG ANCHOR RODS: 2 1/4 0 2.25 in. A615 GR. 75 X 7' -0 LONG 1 (EST Wr = 966 LBS.) g ry Monopole Base Reactions: (Base Reactions For Foundation Design) (2) 1.25" X 35 "0 (50 KSQ MOMENT: 5200 ft-kips _ W/ (12) 3/4 "0 A325 BOLTS SHEAR: 36.0 kips { ON A 31" B.C. (I.D. = 24 ") AXIAL: 55.0 kips i _ Pole Shaft Sections Dimensions: SECTION WALL THK. SPLICE LENGT TOP DIA BOT. DIA. LENGTH FT INCHES FT INCHES INCHES E1.2 20.00 0.1875 0.00 22.000 26.103 1/4" PLATE x 50.00' LONG ° 50.00 0.2500 5.00 26.103 36.359 (EST WT = 4182 LBS.) m 42.00 0.3125 6.00 34.833 43.449 51.00 0.4375 7.25 41.593 52.054 50.25 0.4375 0.00 49.692 1 60.000 SPLICE LENGTH 75 MPH WIND SPEED 50 MPH 10X) ELEVATION DEFLECTION ROTATION WIND SPEED DEFLECTION ROTATION t �s' -o• 195' -0" 1 161.2" 1 7.9' 1 72.0" 3.5' - r Appurtenance List: lev. FT) E ui ment Description: 5/16" PLATE x 42.00' LONG TOP LIGHTNING ROD OPTIONAL (EST WT - 5504 LBS.) 195.0 (12) PANEL ANTENNAS (105 FT2 / 1800 LBS) 195.0 T -ARM MOUNTS 185.0 (12) PANEL ANTENNAS (105 FT2 / 1800 LBS) SPLICE LENGTH = 185.0 T -ARM MOUNTS 6' -0' (t 1076) 175 0 (12) PANEL ANTENNAS (105 FT2 / 1800 LBS) as' -n• 175.0 T -ARM MOUNTS 165.0 (12) PANEL ANTENNAS (105 FT2 / 1800 LBS) 165.0 T -ARM MOUNTS 7/16" PLATE x 51.00' LONG (EST WT = 11178 LBS.) SPLICE LENGTH = -1 7' -3' (t 10%) 43' -0" _r ���•`P� tl S CAR'''' %,� oFESSj 1, 7/16' ti. 7/16' PLATE x 50.25' LONG (EST Wr = 12918 LBS.) - SEAL = 032804 r BASE PLATE: 0 2 1/2' THICK PLATE X 73.50' (ROUND) C O` W /(20) 2 1/4" ANCHORS ON A 67.50' BOLT CIRCLE. MIN. 8' -0' EMBEDMENT INTO CONCRETE. AM A ` „� ��'1..t8.d OCopyright 2011 bv DoMnei En ineen Inc. All Ri ht Reserved POLE: 175 -FT POLE g FT DATE:6728/11 OWNER: AMERICAN T I SITE NAME: CITY OF SITE :274746 POLE ELEVATION LOCATION: CATAWBA CLIENT: TAPP SCALE: NT5 DESIGN : TP -9803 R� REV. DATE: NOTES: ANTENNA COAX INSIDE POLE SHAFT REV. COMMENT: STEP BOLTS TO FULL HEIGHT LAT NG: 35'46 31 POLE DESIGNED FOR MAX 101' FALL RADIUS DAVINCI JOB #: 1 1 23 PAGE OF 1 S -i t RISA Tower Job Page 175 -ft Pole (Fut. 195 -ft) - DaVinci #11235 -1405 1 of 5 Da Vinci Engineering, Inc. Project Date P.O. Box 66 274746, City of Hickory 09:24:36 06/28/11 Unionville Center.OH43077 Client Phone: 614- 937 -4922 Designed by Far TAPP (TP -9803) Mike P :a Tower In ut Data i There is a pole section. This tower is designed using the TIA/EIA -222 -F standard. The following design criteria apply: Tower is located in Catawba County, North Carolina. Basic wind speed of 75 mph. Nominal ice thickness of 0.5000 in. Ice density of 56 pcf. A wind speed of 65 mph is used in combination with ice. Temperature drop of 50 °F. Deflections calculated using a wind speed of 50 mph. A non - linear (P- delta) analysis was used. Pressures are calculated at each section. Stress ratio used in pole design is 1.333. Local bending stresses due to climbing loads, feedline supports, and appurtenance mounts are not considered. Tapered Pole Section Geomet Section Elevation Section Splice Number Top Bottom Wall Bend Pole Grade Length Length of Diameter Diameter Thickness Radius .R J? Sides in in in in LI 195.00-175.00 20.00 0.00 18 -- 22 - 00 - 10 -- 2 - 11 - 01 - 0 -- 0 1 0.7500 A572 -65 L2 175.00- 125.00 50.00 5,00 (65 ksi) 18 26.1000 36.3600 0.2500 1.0000 A572 -65 L3 125.00 -88.00 42.00 6.00 18 34.8340 43.4500 0.3125 1.2500 A572 -65 L4 88.0043.00 51.00 7.25 18 41.5941 52.0500 0.4375 1.7500 A572 -65 L5 43.00 -0.00 50.25 18 49.6886 60.0000 0.4375 1.7500 A572 -65 (65 ksi) Ta ered Pole Pro erties Section Tip Dia Area I r C I/C J /U W w/t in in,? in in in in in i LI 22.3394 12.9812 780.3007 7.7434 11.1760 69.8193 1561.6281 6.4918 3.5420 18.891 26.5026 15.4212 1308.1983 9.1989 13.2588 98.6664 2618.1180 7.7121 4.2636 22.739 L2 26.5026 20.5120 1731.6736 9.1768 13.2588 130.6056 3465.6257 10.2579 4.1536 16.614 36.9209 28.6533 4720.2701 12.8190 18.4709 255.5520 9446.7512 14.3294 5.9594 23.837 L3 36.4129 34.2410 5155.4119 12.2551 17.6957 291.3374 10317.6074 17.1238 5.5808 17.859 44.1203 42.7870 10059.1043 15.3138 22.0726 455.7281 20131.4446 21.3976 7.0972 22.711 L4 43.4849 57.1511 12230.4451 14.6106 21.1298 578.8238 24476.9833 28.5810 6.5506 14.973 52.8530 71.6704 24120.5451 18.3224 26.4414 912.2265 48272.8286 35.8420 8.3908 19.179 L5 51.9658 68.3913 20959.0201 17.4842 25.2418 830.3291 41945.6187 34.2022 7.9752 18.229 60.9256 82.7100 37071.5875 21.1447 30.4800 1216.2594 74191.9547 41.3628 9.7900 22.377 } RISATower Job Page 175 -ft Pole (Fut. 195 -ft) - DaVinci #11235 -1405 2 of 5 Da Vinci Engineering, Inc. Project Date P.O. Box 66 274746, City of Hickory 09:24:36 06/28/11 Unionville Center, OH 43077 Client Phone: 614 - 937 -4922 TAPP (TP -9803) Designed by FAX Mike P 'i Feed Line /Linear Appurtenances - Entered As Area 3 Description Face Allow Component Placement Total C,A,a Wei ht i or Shield Type Number g Leg JT It'(I! Pl 1 5/8" C No Inside Pole 195.0 0.0 18 No Ice 0.0 0.92 f 1 518" C No Inside Pole 185.0 - 0.0 18 o Ice 0.92 ! 0.92 15/8" C No Inside Pole 175.0 - 0.0 18 o Ice 0.00 0 92 0.92 1 5/8" C No Inside Pole 165.0 - 0.0 18 o Ice 0.00 0 92 0.92 1/2" Ice 0.00 0 Discrete Tower Loads Description Face Offset Offsets: Azimuth Placement C or T C444 CAA Weight YPe Hor_ Adjustment Front Side Leg Lateral Vert ft 0 ft ft, f , K ft (12) Panel w/ mounting (105 C None 0.000 195.0 No Ice 105.0 112 / 18 105.0 1.80 (12) Panel 0 1nti 1/2" Ice 125.0 125.0 2.34 1 mounting (105 C None 0.000 185.0 No Ice 105.0 105.00 1.80 R2 / 180 Ins) (12) Panel 1/2" Ice 125.0 125.0 2.34 1 mounting (105 C None 0.000 175.0 No Ice 105.0 105.00 1.80 ft2 / 180 Ibs) 1/2" Ice 125.0 125.0 2.34 (12) Panel w/ mounting (105 C None 0.000 165.0 No Ice 105.0 105.00 1 80 112 / I80 lbs) 1/2" Ice 125.0 125.0 2.34 Load Combinations Comb. Description No. I Dead Only 2 Dead +Wind 0 deg - No Ice 3 Dead +Wind 90 deg - No Ice 4 Dead +Wind 180 deg - No Ice 5 Dead +lce+Temp 6 Dead +Wind 0 deg +Ice+Temp 7 Dead +Wind 90 deg +lce+Temp 8 Dead +Wind 180 deg +lce+Temp 9 Dead +Wind 0 deg - Service 10 Dead +Wind 90 deg - Service I I Dead +Wind 180 d - Service r s t F k RISA Tower J ob Page 175 -ft Pole (Fut. 195 -ft) - DaVinci #11235 -1405 3 of 5 DaHnci Engineering, Inc. Project Date P.O. Box 66 274746, City of Hickory 09:24:36 06/28/11 Unionville Center, OH 43077 Client Phone: 614- 937 -4922 TAPP (TP -9803) Designed by FAX Mike P Maximum Member Forces Section Elevation Component Condition Gov. Force tilafor Axis Minor Axis No. jt Type Load Moment Moment Comb. K ki - L 1 195 - 175 Pole Max Tension 9 0.00 00 - ktP _�1__- -0.00 Max. Compression 5 -6.45 0.00 0.00 Max. Mx 3 -3.76 - 144.75 0,00 Max. My 2 -3.76 0.00 144.75 Max. Vy 3 10.05 - 144.75 0.00 Max. Vx 2 -10.05 0.00 144.75 L2 175-125 Pole Max Tension 1 0.00 0,00 0.00 Max. Compression 5 -18.53 0.00 0.00 Max. Mx 3 -13.21 - 1010.74 0.00 Max. My 2 -13.21 0.00 1010.74 Max. Vy 3 21.77 - 1010.74 0.00 Max. Vx 2 -21.77 0.00 1010.74 L3 125-88 Pole Max Tension 1 0.00 0.00 0.00 Max. Compression 5 -26.89 0.00 0.00 Max. Mx 3 -21.27 - 1841.88 0.00 Max. My 2 -21.27 0.00 1841.88 Max. Vy 3 24.34 - 1841.88 0.00 Max. Vx 2 -24.34 0.00 1841.88 L4 88-43 Pole Max Tension 1 0.00 0.00 0.00 Max. Compression 5 -41.34 0.00 0 Max. Mx 3 -35.06 - 2976.71 0.00 Max. My 2 -35.06 0.00 2976.71 Max. Vy 3 27.41 - 2976.71 0.00 Max. Vx 2 -27.41 0.00 2976.71 L5 43-0 Pole Max Tension 1 0.00 0.00 0.00 Max. Compression 5 -61.05 0.00 0.00 Max. Mx 3 -53.85 - 4424.60 0.00 Max. My 2 -53.85 0.00 4424.60 Max. Vy 3 30.07 - 4424.60 0.00 Max. Vx 2 -30.07 0.00 4424.60 Maximum Tower Deflections - Service Wind Section Elevation Hor:. Gov. Tilt Twist No. Deflection Load n in Comb L I 195-175 72.021 ­I 0 3.5297 0 L2 175- 125 57.428 10 3.3948 0,0000 L3 130-88 29.585 10 2.3727 0.0000 L4 94-43 14.752 10 1.5111 0.0000 L5 50.25-0 4.198 10 0.7651 0 Critical Deflections and Radius of Curvature - Service Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Comb in o Curvature 195.00 02) Panel w/ mounting (105 ft2 / 10 72.021 3.5297 00p0 ,0 1800 Ibs) 15728 185.00 02) Panel w/ mounting (105 ft2 / 10 64.648 3.4817 0.0000 7863 l 1800 lbs) 175.00 0 2) Panel w/ mounting (105 ft2 / 10 57.428 3.3948 0.0000 4029 a RISA Tower Job Page 175 -ft Pole (Fut. 195 -ft) - DaVinci #11235 -1405 4 of 5 Da Vinci Engineering, I Project Date P.O. Box 66 274746, City of Hickory 09:24:36 06/28/11 Unionville Center, OH43077 Client Phone: 614- 937 -4922 TAPP (TP -9803) Designed by FAX Mike P u a i Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load i Comb ip Curvature o 1800 Ibs) 165.00 02) Panel w/ mounting (105 ft2 / 10 50.500 3.2399 1800 lbs) 0 0 � 3256 Maximum Tower Deflections -Desi n Wind Section Elevation Horz. Gov. Tilt No. Deflection Load Twist ✓ in Comb o o L I 195 175 161.207 3 7.9052 0.0000 L2 175- 125 128.604 3 7.6040 0.0000 L3 130-88 66.332 3 5.3191 0.0000 L4 94-43 33.098 3 3.3899 L5 50.25-0 0.0000 9.424 3 1.7174 0.0000 Critical Deflections and Radius of Curvature - Design Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load n Comb i o o Curvature 19500 (12) Panel w/ mounting (105 ft2 / 3 161.207 7.9052 0.0000 J? 1800lbs) 7259 185.00 (12) Panel w/ mounting (105 ft2 / 3 144.736 7.7981 0.0000 1800lbs) 3628 175.00 02) Panel w/ mounting (105 112 / 3 128.604 7.6040 0.000b 1800lbs) 1856 165.00 0 2) Panel w/ mounting (105 ft2 / 3 113.119 7.2579 0.0000 18001bs) 1494 Pole Design Data Section Elevation Size L L. Kl /r F A No. Actual Allow. Ratio / P Po P ./ ./ ksi in' K K P L I 195-175(l) TP26.1 x22x0.1875 20.00 0.00 0.0 39.000 15.4 212 - 3.76 601.43 0.006 L2 175-125(2) TP36.36x26. I x0.25 50.00 0.00 0.0 39.000 27.8392 13.21 1085.73 0.012 L3 125-88(3) TP43.4504.8340.3125 42.00 0.00 0.0 39.000 41.5662 21.27 1621.08 0.013 L4 88-43(4) TP52.OSx41.5941x0A375 51.00 0.00 0.0 39.000 69.6064 -35.06 2714.65 0.013 L5 43-0(5) TP60x49.6886x0.4375 50.25 0.00 0.0 39.000 80.7753 -51.82 3150.24 0.016 s Pole Bendin Desi n Data Section Elevation Size Actual Actual Allow. Ratio Actual Actual Allow. Ratio No. Actual fb. Fb. fb. Mr jbr Fbr f b, kip-ft ksi ksl Fr. kip-ft ksi ksi F L I 195-175(l) TP26.1 x22x0.1875 144.75 17.605 39.000 0.451 0.00 0.000 39.000 0.000 L2 175-125(2) TP36.36x26. I x0.25 1010.74 50.288 39.000 1.289 0.00 0.000 L3 125-88(3) TP43.45x34.834x0.3125 39 0 0 � 1841.88 51.401 39.000 1.318 0.00 0.000 39.000 0.000 LA 88-43(4) TP52.05x41.5941 x0.4375 2976.71 41.525 39.000 1.065 0.00 0.000 39.000 0.000 L5 43-0(5) TP60x49.6886x0.4375 4221.78 43.680 39.000 1.120 0.00 0.000 39.000 0.000 I ( ) RISA Tower Job Page 175 -ft Pole (Fut. 195 -ft) - DaVinci #11235 -1405 5 of 5 Da Vinci Engineering, inc. Project Date P.O. Box 66 274746, City of Hickory 09:24:36 06/28/11 Uniorrv;lle Center, OH 43077 Client Phone: 614- 937 -4922 Designed by FAX.- TAPP (TP -9803) Mike P 0 E Pole Shear Design Data Section Elevation Si ks; Actual Actual Allow. Ratio Actual Actual A1Jow. Ratio No. f F re Ac ft f T fw F. f. F L I 195 - 175 (1) TP26.1 x22x0. 1 875 10.05 ksi 0.652 26.000 0.050 0.00 0.000 26 - 0()00.0 kip Il kit ksi F00 L2 175-125(2) TP36.36x26.Ix0.25 21.77 0.782 26,000 0.060 0.00 0.000 26.000 0.000 L3 125-88(3) TP 24.34 0.586 26.000 0.045 0.00 0.000 26.000 0.000 L4 88-43(4) TP52.05x41.5941 x0.4375 27.41 0.394 26.000 0.030 0.00 0.000 26.000 0.000 L5 43-0(5) TP60x49.6886x0.4375 29.85 0.370 26.000 0.028 0.00 0.000 26.000 0.000 Pole Interaction Design Data Section EJevation Ratio Ratio Ratio Ratio No. Ratio Comb. AJlow. P f x fey f Criteria Fw Stress Stress P° Fe: Fe,, F F Ratio Ratio L 1 195 - 175 (1) 0.006 0.451 0.000 0.050 0.000 0.458 1.333 ✓ HI -3 +VT L2 175-125(2) 0.012 1.289 0.000 0.060 0.000 1.303 1.333 H1 -3 +VT L3 125-88(3) 0.013 1.318 0.000 0.045 0.000 1,332 1.333 ✓ H1 -3 +VT L4 88-43(4) 0.013 1.065 0.000 0.030 0.000 1.078 1.333 HI -3 +VT 10 L5 43-0(5) 0.016 1.120 0.000 0.028 0.000 1.137 1.333 H 1 -3 +VT V Section Capacity Table Section Elevation No. ft CO TyPe ent Sire Critical P SF•P % Pass j Element K K Capacity Fail LI 195 - 175 Pole TP26. I x22x0.1875 1 -3.76 801.70 34.4 Pass L2 175 -125 Pole TP36.36x26.Ix0.25 2 125 - 88 Pole 1 L3 -13.21 1447.28 97.7 Pass TP43.45x34.834x0.3125 3 -21.27 2160.90 99.9 pass L4 88-43 Pole TP52.05x41.5941 x0.4375 4 LS 43-0 p 35.06 3618.63 80.9 Pass TP 5 -51.82 4199.27 85.3 pass x Summary Pole (L3) 99.9 pass RATING = 99.9 Pass } s I i e s s Flange Plate Analysis - According to TIA /EIA -222 -F 1996 x Base Reactions Plate Geometry Bolt Geometry Moment 4425 ft -kips B.C. 67.5 in Pole Dia. 60 Shear 30 kips Fy 50 ksi Bolt Dia. 2.25 Axial 54 kips Diameter 73.5 in No. Bolts 20 Thickness 2.5 in Bolt Grade <#181 Bolts Bolt Moment of Inertia 11390.63 in Max Bolt Tension 157.3 kips Max Bolt Compression 160.0 kips BOLTS 82.6% Combined Force 161.1 kips Allowable Bolt Capacity 195.0 kips Bending in Plate Plate Moment 422.8 in -kip Bend Plane 9.4 in Plate Capacity 490.8 in -kip PLATE 86.2%] { F, f Y i f i i i, f i E f= g: r