Loading...
HomeMy WebLinkAboutMEC2009-01088.tif $A C� CATAWBA COUNTY PERMIT MECHANICAL (R) New Building P. O. Box 389 100A Southwest Blvd PERMIT NO: MEC2009 -01088 APPLIED: 08/04/2009 Newton, North Carolina 28658 ISSUED: 11/16/2009 1 84 2 SM Phone: 828 - 465 -8399 EXPIRES: 05/15/2010 FAX: 828 - 465 -8484 www.catawbacountync.gov APPLICANT OWNER CONTRACTOR JEFFREY A HEFNER CENTURY SERVICES 1630 SAIN RD PO BOX 57 HICKORY NC 28602 HICKORY NC 28603 PROPERTY ID#: 370009060471 CENSUS TRACT: STREET ADDRESS: 1584 SAIN RD, HICKORY, NC LOT# PROJECT DESCRIPTION: INSTALL HVAC SYSTEM ** *fee paid w/ bld permit DIRECTIONS HWY 10 W/ RT ON HWY 127 N/ RT ON BERHEL CHURCH RD/ RT ON SAIN RD/ ABOUT 1/2 MILE ON LIFT COMMENTS: IMPORTED WORK CLASS: New Building TOTAL SQ FT TYPE OF USE: RES Related Permits for primary subcontractors associated with this project: Additional permits for other related work will be issued as needed (i.e. gas lines, unit heaters, etc.) • These Permits will remain inactive until an application from the subcontractor is received by the Permit Center. Once the Permit is activated, scheduling through the IVR system will be permitted. FEE DESCRIPTION DATE FEE AMOUNT Residentia Mechanical Fee 08/04/2009 $0.00 TOTAL FEES $0.00 Catawba County has an agreement with Garbage Disposal Service, Inc. granting them an exclusive license to transport and dispose of all solid waste, including construction and demolition debris in the unincorporated areas of the County. The approval of your application for a construction/building permit is made specifically contingent upon your agreement not to utilize any other business or company to transport and/or dispose of solid waste from construction site(s). Failure to comply with this provision may result in assessment of fines up to $500 per day. This permit is issued on the express condition that the above work shall conform in all respects to the statements certified to in the application for such permit, and that all work shall be done in accordance with all applicable zoning, building, electrical, plumbing and mechanical ordinances of the County of Catawba and the State of North Carolina. A permit issued for work under this Code shall expire by limitations six months after the date of issuance if the work authorized (FOOTINGS ARE CONSIDERED Ist INSPECTION ON NEW CONSTRUCTION) has not been commenced. If after commencement the work is discontunued for a period of 12 months, the permit therefore shall expire. If a project expires, a minimum fee per the current fee schedule will be charged for each building and trade permit to reactivate the project. * * *AN ADDITIONAL CHARGE PER THE CURRENT FEE SCHEDULE MAY BE ASSESSED FOR EACH UNWARRANTED INSPECTION SCHEDULED. * ** If there are any questions, please contact the office between 8:00a.m, and 5:00p.m. 0 permit Page I of 1 Nov,16, 2009 10:49AM Century Se vices No.1571 P. 1 (828) 465 -8399 Office Number Catawba County FAX CALL ❑ WITH ISSUED PERMIT # (828) 465 -8962 Newton Fax Number plication for Permit TO THIS NUMBER (�) Lit S 1$28) 321 -6814 Hickory Fax Number J www.catawbacountync.gov (Please print or type) !( P.0 Box 389 Newton, NC 28658 Type of Permit ❑ EI ctrical ❑ Plumbing Mechanical ❑ Fire Date I Active Building / Mobile Home Permit # 8L t0 5 a Property ID # (if known) 3'7 0004Q t;,n0'i'7 * If no active Building or Mobile Home permit please list driving directions from a major intersection: Use of structure: ❑ Mobile Home Single family ❑ Multi family ❑ Commercial ❑ Industrial /Factory ❑ Church Owned ❑ Gov't Owned ❑ Accessory Physical 911 Address of Project 15% S ArN R. op► c k a(4s. M C- Owner or Business 7� F' ur Ftile-q- Telephone _ 3 a0 - 3 a3o Address Scov,n� Subcontractor O g rvit-Lxr u Telephone _26 —W W - a 11'a, Address bgin j� 5J K)OuAOD ILA QLA a�SA icense# �Al2J -I - 38163 - 5k = s 1) General Contractor Telephone Design Professional Telephone Address NC Reg # ELECTRICAL Panel # 1 Amps Panel # 2 Amps Panel # 3 Amps Panel # 4 Amps ❑ New Panel ❑ Pole Service ❑ Wire Mechanical unit only (No Svc Chg) Total# ❑ Sub Panel ❑ Service Change Amps_ ❑ Interior Wiring (No Service Change) ❑ Saw Service ❑ Load Control ❑ Modular Home ❑ Sign Service ❑ Mobile Home ❑ Other (List) 'List each panel installed separately' ❑ RV Service Total Electrical Cost $ PLUMBING ❑ Full or Partial Bath/Toilet Rooms.(Includes future.) [] Fire Sprinkler System (❑ New p Addition ) Total number being installed ❑ Gas Line /Pressure Test only ❑ Mobile home (new set -up only) ❑ Modular Home ❑ Water Heater (Electric, Gas) ❑ Other (List) MECHA ICAL (Check One) ew Installatio ❑ Change out exiting system Heat Pum or Furnace with A/C Total #�, E] Gas Line/ Pressure Test E] Other (List) ❑ Furnace (Oil, Gas, or Electric) Total # ❑ Gas Logs Total # ❑ Air Conditioner Total # _ ❑ Unit Heater Total # ❑ Water Heater (Electric /Gas) Total # _ ❑ Modular Home FIRE (Check permit type applicable) ❑ Fire Extinguishing System ❑ Compressed Gases ❑ Spraying & Dipping ❑ Fire Alarm0etection System ❑ Hazardous Materials ❑ Standpipe Systems ❑ Fire Pumps & Related Equipment ❑ Industrial Ovens ❑ Temp, Membrane Structures ❑ Flammable & Combustible Liquids ❑ PVT Fire Hydrants ❑ Other — All fees entered by Permit Center, DOUBLE FEE charged for work started prior to obtaining permit. "The undersigned makes application for permits and inspection of rk described agrees to comply with all applicable State, County codes and laws regulating the work. PRINT NAME / SIGNATURE "E (-- (Subcontractor) License Holder /Owner . Dec, 22' 2009E11.34RM Century Services" No. 2080 P. 1 Newton, NC 28658 PO Box 57 Hickory, NC 28603 - Phone: 8284662112 Fax 8 entury w Sen 3r c� 'y Services ww.CenturyriCesHVAC.COm /1 To: 1/U L `7 0 -reYOOri From, Fax: Pages: Phone: Date: 2 IZZ /1 O Re A mi, d /L/5G' 2 0 D q CC: ❑ Urgent ❑ For Review ❑ Please Comment ❑ Please Reply ❑ Please Recycle e Comments: D � �� �.. � /97/tJ r E7��� �SS L�af 4 C� c•s¢ y7Q�G ------------------------------------------ I ---------------------------------------- Get 90 days Same as Cash financing on select Looking for ways to stop the flu virus next flu Trane systems. season ... Ask us about Trane CleanFffects Air Filtration Systems. I , I 1 1 Call today for details.,. ; 828 -466 -2112 Fast & Secure online approval Call today and start enjoying clean air... www.CenturyServicesHVAC.com 828 -466 -2112 www.CenturyServicesHVAC.corn I , Dec.22, 2009 11:34AM Century SerVI'CeS', No. 2080 P. 2 f Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Douglas n , NC 1 Lincolnto NC 28092 Jeffery Heafner Pro 'ec Re ort - F :Gineraf Pr oject Info rmation - -- �-- -- �Project Title: Jeffery Heafner Project Date: Tuesday, October 13, 2009 Company Name: Century Services Company Representative: Douglas Bivens Company Address: 680 Boundary St. Company City: Newton, NC 28658 Company Phone: 828 -466 -2112 Company Fax: 828 -465 -2666 Company E -Mail Address; dbivens@centuryserviceshvac,com Company Website: www.CenturyServicesHVAC.com Company Comment' .::A. �!( ...r:::::z,i • - , :- v ::r.::,!}fli'Lloii::siiii, ,:a:3v ?.:. .._......._...., iP:iFiic ..- _........EMT .......�{..r�. -nt �......,.. 1: ?::::::: �::� c -: ",'r* - ;;...._.......,, ....r....._..,...r .... ... .W,, ,,.,.,.4•._.. ...............�, ,�`,:::,:.:...r.E ,• � :,,::::•::{ � ,... ....__.....Ir�..........,.1�+., < a ,S,.,............1 :.,:::•: :::_ Reference City: y Hickory, North Carolina Building Orientation: Front door faces West Daily Temperature Range: Medium Latitude: 35 Degrees Elevation: 1187 ft Altitude Factor.- 0.958 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb _Rel.Hum Rel.Hum Dry Bulb Difference Winter: 18 16.61 80% n/a 72 n/a Summer: 95 75 40% 50% 75 37 _ g ....._., tt,�..._..., s } �, 241,r .: �,a. . -; f 'I +' _,._ 11 }F,'a= #!�f ='='= .' iPi__. . W ,- . _ a.�s 6, w .1, ,,,.,, _..,�, :�: = ::,1�(';: Total Building Supply CFM: 2,400 CFM Per Square ft.: 1.0422 Square ft- of Room Area: 2,303 Square ft. Per Ton: 431 Volume (ft') of Cond. Space: 34,830 _. t .:., ,:;= :_:;' :'r;r.;_ � -� !,::_:::�:( ;,•::..: ..::,.,....��:...,.:,- ::- ::::.. . .JSS...,..., -. .,..2. .........11..r, , __ - -.. X3 ..._...... Lri #6 ... . 4 ............. _.._f, r '.:._._, � �:!•::;. ��! iti+�:,.�:, ; �ii�i.:: =_::: pf;S �� _ ;':'•�; } ° :i; =�; ?pi. � �.':�i', Total Heating Required Including Ventilation Air: 62,157 Btuh 62.157 MBH I .�... ._ +..:......_...,.., ,t Total Sensible Gain: 44,860 Btuh 89 % Total Latent Gain: 5,747 Btuh 11 % Total Cooling Required Including Ventilation Air; 50,607 Btuh 4.22 Tons (Based On Sensible + Latent) 5.34 Tons (Based On 70% Sensible Capacity) Notes - Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads, L _ C:1Documents and SettingskdouglasMDesktoplLog Home Load.rhv Tuesday, December 22, 2009, 11:36 AM J D ec, 22. 20 1 Century Services No, 2080 P. 3 FtJtvac - ResWential'3 Light Commercial HVAC Loads gougias givens Elite Software Developmsnk Inch Jeffery Heafner Liricoln NC 2 L oad P Report _ J Has; Net Rec fl.' Sen. Lat Net Sen Scope AED' T Sys; Sys: Sys; ` Clp; Act: jSize Ton: /Ton:: Area: Gain( Gain; Gain' Loss; Htg CFM; CFM: CFM 81l dnq 4,22 5.34 431 2,303 44,860 5747 50,607 62,157 2,400 2,400 2,400 System 1 Yes 2.58 3.23 397 1,281 27,128 3,818 30,945 40,002 1,400 1,400 1,400 Duct La tan t 857 857 Zane 1 975 20,029 1,489 21,518 20,160 706 950 950 14 1 -Main LIving Area 975 20.029 1,489 21,518 20,160 706 950 950 9 -6 Zone 2 306 24,157 1,472 25,629 19,842 694 1,146 1,146 16 4- Sunroom 306 24,157 1,472 25,629 19,842 694 ;1.,148 1,146 10-6 System 2 No 1.64 2.11 484 1,022, 17,732 1,930 19,662 22,155 1,000 1,000 1,000 16 Duet Latent. 682 882 Zone 1 511 9,427 566 9,993 9,924 448 447 447 10 2- Masler Beal Area 11 9,427 $66 9,993 9,924 448 447. 447 4 -6 Zone 511 14,429 682 15.111 12,230 552 685 685 12 3-Bed Area 2 / KIU Laund 11 14,429 682 15.111 12,230 552 ;.;; 685 685 6 -6 Sean Of mom airflows may be greater than system airflow because system has muliplezones. ClDocuments and SettingsldouglasblDesktoplLog Home Load.rhv Tuesday, December 22, 2009, 11:36 AM