HomeMy WebLinkAboutREHA-7-10-8902 Bullentin Drawing for Canopy Footing.tif `l-10- ggo2
I
PREFABRICATED CANOPY
COLUMN SIZE AND
3 #5 x 2' -2" ; ; ANCHORAGE TO FOUNDATION
EACH WAY i TO BE SPECIFIED BY CANOPY
BOTTOM i MANUFACTRUER
CENTER ON
COLUMN
::
WRAP EXISTING PIPES IN
3/4" THICK COMPRESSIBLE
I� h PIPE INSULATION FULL
LENGTH OF PIPE THROUGH
r? xx i� I ; FOOTING
I� �I
.I 6"
MIN.
z
EXTEND FOOTING AS
REQUIRED TO ENCASE
EXISTING PIPES
3"
MIN. EXTEND EXCAVATION
ALL TO 2,000 PSF BEARING
SIDES 2'- 8 "x2' -8" CAPACITY SOIL
MINIMUM FILL WITH CONCRETE,
LEAN CONCRETE OR
COMPACTED FILL
3 SECTION
S202 SCALE: 3/4"=V-0"
p y in CharW J. Amfietd
project " ow. P. Ritchie Newton- Conover Middle School 112.6051.00
Drawn g P Ritchie Conversion to Elementary School
6/22/11
Tbi.r drawng and the derign ibo" am the
properly of Lluk !)iYerrifud Arcbitectaral
Consu&ng. The rcprodndion, copying or
otl�ernfeofthitdrouinguRtboutr /xirwiNen Canopy Column Footing
con.rmi it prohibited and any infringement Revision
will he to jed to legal action. 7 77
Q uN �u