Loading...
HomeMy WebLinkAboutELE2006-00299.tif P.O. Box 389 ELECTRICAL Newton, NC 28658 PERMIT Phone: (828)465 -8399 I v / ► i Fax: (828)465 -8962 PERMIT NO.: ELE2006 -00299 APPLIED: 02/06 /2006 Web Site: www.catawbacountyne.gov ISSUED: 02/06 /2006 Popular Pages / Online Permit Center EXPIRES: 08/06/2006 SITE ADDRESS: 4706 GOLD FINCH DR DENVER NC ASSESSOR'S PARCEL NO.: 460601167572 TYPE OF WORK: NEW CONSTRUCTION TYPE OF USE: SWIMMING POOL BUILDING SQ. FOOTAGE: sf PHYSICAL DIRECTIONS: 16S / LF ON CAMPGROUND / LF ON CATAWBA BURRIS / FIT ON BANKHEAD / LF ON GOLDFINCH / FIRST LOT ON RIGHT PROJECT DESCRIPTION: PRIVATE INGROUND SWIMMING POOL LOCATED BEHIND HOUSE/ PEBBLE BAY PH 3 / LOT 128 OWNER /APPLICANT CONTRACTOR 1 CONTRACTOR 2 POOL BY DESIGN AVTECH ELECTRIC CONTRACTOR; 1408 AUTUMN RIDGE LN 5612 LANTANA AVE ,,. CHARLOTTE NC 28203 CHARLOTTE SWT #100 Electrical Fixtures Fees Fixture Type Amps Quantity Minimum Fee 1 Type By Date Amount PRMT RAG 02/06/2006 $61.00 Total: $61.00 This permit is issued on the express condition that the above work shall conform in all respects to the statements certified to in the application for such permit, and that all work shall be done in accordance with all applicable zoning, building, electrical, plumbing and mechanical ordinances of the County of Catawba and the State of North Carolina. A permit issued for work under this Code shall expire by limitations six months after the date of issuance if the work authorized (FOOTINGS ARE CONSIDERED 1st INSPECTION ON NEW CONSTRUCTION) has not been commenced. If after commencement the work is discontunued for a period of 12 months, the permit therefore shall expire. * * *AN ADDITIONAL CHARGE PER THE CURRENT FEE SCHEDULE MAY BE ASSESSED FOR EACH UNWARRANTED INSPECTION SCHEDULED. * ** If there are any questions, please contact the office between 8:00&m. and 5:00p.m 1 02,'0712005 11:59 7043343483 POOL E`,' DESIGN PAGE 01 FEB -06 -2006 15 :36 CATAWBA COUNTY 1. 828 465 8962 P.01 /04 216/7,606 CA.TAWBA COUNTY 2:5arm ZONING PERMIT APPLICATION �.r v PO BO 384 ACCESSORY v� 100 A SOUTHWEST PERMM NO.: ZON2006 -00092 / BL. 'D APPLIED: 02/0612006 r NEKTON, NC 28658 ISSUED: 0210612006 EXf'MES: 08/06M06 PHONE 828- 465 -8380 - - -------------------------- -.•... - -- -- ------ - - -.._ - - - - -- -- Avglicant: Owner: Contractor: POOL BY DESIGN MICHAEL HARPER 1408 A'UT'UivIN RIDGE LN PO BOX 1463 CHARLOTTE. NC 28203 MATTHEWS NC 28105 Primary Phonc: 704- LOCATION: PIN NUMBER 4450601167572 E -911 ADDRESS 4706 GOLD PINCH DR SETBACKS., CENSUS TRACT Front 30 TYPE OF PERMIT: SWINTN1I' ,4G POOL Sidc 10 ; LNFOFOIATION: ZONING CL.AS31FICAT10N: R -2 Rear 5 SfZE OF LOT. 1.52 Maximum Wall Height: 36 100 YEAR FLOOD PLtMN? N FLOOD PLAIN. STRUCTURh1 N PROPERTY OWNERSHIP P1rT ; 1. Before an impecbon can be made by'the Building Inspution Office, the applicant must pull astring to de0gnats tfle aide and retuproperzy ,lines where t}w structure is being placed or constructed. Z. Accessory structures shall only be Ibcated in side or roar yards i 3. Accessory structures shall not be attached in any way to the pri nciple structure. 4. Accessory structure shall only be used for private residential purposes. 5 Manufatxuved homes sliall not be wed as accessory structures. 6. Accessory structures may not be us--d for living purposes. CON ML NTS: .PRIVATE INGROUND SWIMMING POOL LOCATED BEHIND HOUSE / PEDDLE BAIT PH 3 / LOT 129 P, The appliCS t Ag certifies t ati aA lufourtation Anrl attachmenLv to th Certiflsate of Zoning Compliance are true grail correct. cknowled= that this perrrAt MA Jlssued on the basi aft aInfotrmation required herein The sppficartt tlnthdl" acicnou+ledges that any consrfucdcn, alteration or addition which differs from this appli cation shall be subject to removal or alp -rabon so ns to bring said structure into conforinance with the specifications and standards of the Catawba Co" Toning Ordinance. Such corrective action shall be' the cxpense of the applicant. It is the responsibility of Applicant to comply with all existing decd mRHcdons pertaining to the property. Issuance of this permit is not cenlrlct ion of such compliance and doe; not vtlieve Applicant of rite duty to comply. This zomnA permit application hall ex ire six months from the data: of issuance unless a building permit is secured cmd mmarins active- Fees [CANT'S GN.tiTC' Type By Date Amount's j Residential Permits .RAG 02/06/2006 25,00 ZONING APPROuED BY *w70NING FEES ARE NON- PEFLWI)ABLE'"" k FEE -07 -2006 11:51 7043343483 97% P.01 ! JAN -30 -2006 16:26 CATAWBA COUNTY 1 828 465 8962 P.03 (828) 465 -8399 Office Number %,i%tAWU0 %,VUI tty t LJ t.ALL LJ vvl 1 n looucv rr-nwm,r t j (828) 465 -8962 Newton Fax Number Application for Permit TO THIS NUMBER (_ ) (828) 322:6814 Hickory Fax Number C I www.catawbacountync.gov (Please print or type) P.0 Box 389 Newton, NC 28658 Type of Permit [Electrical ED Plumbing ❑ Mechanical ❑ Fire Date 4D Active Building / Mobile Home Permit # Property ID # (if known) * If no active Building or Mobile Home permit please list driving directions from a major intersection: Use of structure: ❑ Mobile Home ❑ Single family ❑ Muni family ❑ Commercial ❑ Industrial/Factory ❑ Church Owned ❑ Gov't Owned (�Aad�sory Physical 911 Address of Project 4 � 7� 80 J — Fn , ,? t, cJ/) � g — D P r\! lX' Owner or Business a D Telephone _7Cet _ 333 - 2 Address �l2 Z Subcontractor - e ' e Telephone Address 7—$ZI 4icense # General Contractor Telephone Design Professional Telephone Address NC Reg # D(l-J3c1- 3gF-7 (-�al� ELECTRICAL (List each panel separately) Panel # 1 Amps Panel # 2 Amps Panel # 3 Amps Panel # 4 " ps ❑ New Building Wiring ❑ Pole Service 0 Wire Mechanical unit only (No Svc Chg) Total#777 ❑ Additional Service (existing bldg) ❑ Service Chg. Amps ❑ Interior Wiring (No Service Change) ❑ Addition of Sub Panel ❑ Load Control ❑ RV Service ❑ Saw Service ❑ Mobile Home ❑ Other (List) ❑ Sign Service ❑ Modular Home Total Electrical Cost $ i , 500 ❑ Service Repair WSwimming Pool (work you will perform) ✓,Bonding Associated Wiring PLUMBING r ❑ Full or Partial Bath/Toilet Rooms,(Includes future.) Total number being installed ❑ Gas Line /Pressure Test only ❑ Mobile home (new set -up only) ❑ Modular Home ' Q Water Heater (Electric, Gas) ❑ Other (List) MECHANICAL (Check One) ❑ New Installation ❑ Change out exitirg systein ; ❑ Heat Pump or Furnace with A/C Total #_ ❑ Gas Line/ Pressure Test ❑ Other (List) ❑ Furnace (Oil, Gas, or Electric) Total # ❑ Gas Logs Total # _ ❑ Mobile Home ❑ Air Conditioner Total # _ Q Unit Heater Total # ❑ Water Heater (Electric /Gas) Total # _ ❑ Modular Homed • FIRE (Check permit type applicable) ❑ Fire Extinguishing System ❑ Compressed Gases ❑ Spraying & Dipping ❑ Fire Alarm /Detection System ❑ Hazardous Materials ❑ Standpipe Systems ❑ Fire Pumps & Related Equipment ❑ Industrial Ovens ❑ Temp. Membrane Structures ❑ Flammable & Combustible Liquids ❑ PVT Fire Hydrants ❑ Other " All fees entered by Permit Center, DOUBLE FEE charged for work started prior to obtaining permit - "The undersigned makes application for permits and inspection�of work described ar agrees to comply with all applicable State, County codes and laws regulating the work. ' ORINT NAME VV1 ' ' N` SIGNATURE _ f i � � A Subcontractorl License Holder /Owner G: \BLD \Web Page Bld srvs & Permit ctr \Blank Applications \2004 -06 TP.ADBAPPJWEWREVSSED.D000reated on 06/09/2004,11:07 PM TOTAL P.03 a 02/0'2!2006 14:14 7043343493 POOL BY DESIGN PAGE 02 i i I PO BY DE 217 Fwrwood Ave. Cbarlotte. NC. 28203 (704) 333 -7446. www_poolbydesiguxom o February 2, 2006 y a F n Rhonda Dear Rhonda, Subject /lntclt Pool The septic tank for the Amdt residence at 4706 Godlfinch Drive has not to this date been installed on the property. The pool location is the same as on the Health Department original application. Thank you, L Jacque Tillman Office Manager Pool by Design jlt i I i i FEB -O� -?005 14 �5 70ti334348? 97 P.02 I I Catawba County, North Carolina This Wrap product was prepared front the Catawba County, NC, Geographic Inf - -nation System. N Catawba County has made substantial efforts to ensure the accuracy of location (a id labeling information contained oil this reap. Catawba Comity promotes and recommends the independent verification of arty data contained on this map product by the user. The County of Catawba, its employees, agents and personnel disclaim, and shall not be held liable far arry and all damages, loss or liability, whether direct, indirect or consequential which arises or may arise this map product or the use thereof by any person or entity. Selected Parcel Number: 4606 -01 -16 -7572 1 inch equals 60 feet Prepared for: 0 0 1.45A �t 7V 87 1 C? r 75 i VIP& F l i R-2, c 07 N W �4 1.6,A 129 � L 1 ... c .- - - 3 - - - • THIS IS NOT A LEGAL DOCUMENT Monday, February 06, 2006 02:44 PM x `ktr CATAWBA COUNTY HEALTH DEPARTMENT ~ n. Telephone: (828) 465 -8270 TDD: (828) 465 -8200 WLS # -20055 " 1, :� 1 -41 � - ment Permit C Re air rmit. Operation Permit. System Type Well Permit. Replacement Well rlAgent'; Phone h' press Po 54 X 4 1 Subdivision f" r t ection/Block/Phase Lot# t 'e, Lot Size - Direc tions: Property Address e Facility: House e Mobile Home - Business Multi- family Other: Pin Number t - 16- 7 . Other Zoning Approval # # Bedrooms Flow # Seats # Employees_ Application Rate GPD Flo, Hot Tub or Tp Special Fixtures Basement ye 100% Repair Are, ­ gvno Basement Plumbing yes /no Water Supply: Private Well Publi Semi - Public Type of System: Trench Bed Pump Pump /Panel Panel LPP Othe � 4�1r Segtxc'"Tank Siz Pump Tank Size Nitrification Field: Total Square Feet ' 73 3 3 Depth of Stone IU Bed Size Trench Width " Total`I ength` All Tr2mehes NunTber of Trenches ' J Trench Length 0 l i_1 / /_l / Feet on Center Maximum Trench Depth 0 , " Distance of Nearest Welk " *DO NOT INSTALL SEPTIC WHEN WET* *WELL RECORD REQUIRED AT COMPLETION* Topo % Slope I y Texture l Structure Clay Min. I" Soil Wetness " Soil Depth Restric. Hoz. at Available space yes /no ` - prall Class S PS U ents: t i I ,M; r Ito Filter Required I lUtp ;! Riser required when I t tank is more than 6 I inches deep. * *NO GUARANTEE OR WARRANTY IS IMPLIED OR GIVEN AS TO THE PERFORMANCE OR LENGTH OF TIME THIS SYSTEM WILL FUNCTION ** An Authoriiation to Construct is valid for (5) five years from date issued and is not transferable. Well Permit valid for 5 years provided site conditions do not change. Well location, installation, and protection must meet state and local regulations, and must be inspected and approved by a representative of the Catawba County Health Department before any portion of the installation is put into use. siting of the well by the Health Department staff is to provide protection from known possible sources of contamination. No volume of ater is guaranteed at any �te b the Health Department. ,r Pe t. j t Date /._ l EHS Owner /Agent '_. Septic Tank Installed-by Date EHS Well Installed By Well Grout Approval Date Well Head Approval Date Date Sample Collected j Date of Results Results EHS White - Offire Yellnw - Owner /Aaent Pink - Aididina Tnenertinn Anthnri7ntinn to f nnctnirt i a CATAW BA COUNTY NC - Parcel Report Information Regarding Selected Parcel(s) Parcel ID: 4606 -01 -16 -7572 Name: HARPER MICHAEL E Name2: Address: PO BOX 1483 4ddress2: ►"City: MATTHEW S State: NC Zip: 28106 -1483 Account: 169853 Calc Acreage: 1.52 Tax Map: LRK: 802821 Deed Book: 2697 Deed Page: 1875 Subdivision Name: PEBBLE BAY PH 3 REVISION Subdivision Block: Lots: 128 Plat Book: 62 Plat Page: 103 Building Number: 4706 Street Name: GOLDFINCH DR Site Zip: 28037 Township: MOUNTAIN CREEK Fire Code: DENVER RURAL City Code: COUNTY School Code: CATAW BA COUNTY State Road: Total Bldgs Value:0 Land Value: 43400 Total Value: 43400 Year Built: Year Remodeled: Neighborhood: 131 Watershed: Watershed Split: Voter Precinct: P41 E911 District: COUNTY Matrix: Zoning: R -2 Zoning2: Zoning3: Zoning Split: N Zoning District: COUNTY Split Zoning Dist: N Split Zoning Dist(1): 0 Split Zoning Dist(2): 0 School District: COUNTY Elementary School: SHERRILLS FORD ELEM Middle School: MILL CREEK MIDDLE High School: BANDYS HIGH School Split: NO P &Z Case Number: Census Tract 2000: Census Block 2000: Recorded Date: Lot Type: Small Area Plan: SHERRILLS FORD Printed: Monday, February 06, 2006 02:44 PM i I N O CIA v a O O O oc CC O O C yg Or C �+ 000 00 C 00 C O d O Ca � O O � Fr z w C O 'T C c E cq V Q O O O M 7 O O M N O O O o � � o C C o Z o � cC Cd ,a W U � a C C W cl. C0. o w � d o � U � c W ea Q L CO Q Q+ � N N O O O � O O O O O Z o N y N .O R � Q Y W N +- R CL Swimming Pools, Spas, and Hot tubs j The following information regarding barriers surrounding swimming pools, spas and hot tubs is provided for your review. This information is not a regulatory requirement by Catawba County or the municipalities located within this County. We recommend that you notify your insurance agent prior to this installation, they should be able to provide you with any mandatory requirements relating to your pool, spa or hot tub. I Barrier Requirements Application. The provisions of this chapter shall reference the design of barriers for residential swimming pools, spas and hot tubs. These design references are intended to provide protection against potential drowning and near - drownings by restricting access to swimming pools, spas and hot tub s. Outdoor swimming pool. An outdoor swimming pool, including an in- ground, aboveground or on- ground pool, hot tub or spa shall be provided with a barrier that shall comply with the following: 1. The top of the barrier shall be at least 48 inches above grade measured on the side of the barrier that faces away from the swimming pool. The maximum vertical clearance between grade and the bottom of the barrier shall be 2 inches measured on the side of the barrier that faces away from the swimming pool. Where the top of the pool structure is above grade, such as an aboveground pool, the barrier may be at ground level, such as the pool structure, or mounted on top of the pool structure. Where the barrier is mounted on top of the pool structure, the maximum vertical clearance between the top of the pool structure and the bottom of the barrier shal l be 4 inch - diameter. 2. Opening in the barrier shall not allow passage of a 4 inch - diameter sphere. 3. Solid barriers which do not have openings, such as masonry or stone wall shall not contain indentations or protrusions except for normal construction tolerances and tooled masonry joints. 4. Where the barrier is composed of horizontal and vertical members and the distance between the tops of the horizontal members is less than 45 inches, the horizontal members shall be located on the swimming pool side of the fence. Spacing between vertical members shall not exceed 1.75 inches in width. Where there are decorative cutouts, they shal l not exceed 1.75 inches in width. 5. Where the barrier is composed of horizontal and vertical members and the distance between the tops of the horizontal members is 45 inches or more, spacing between vertical members shall not exceed 4 inches. Where there are decorative cutouts within vertical members, spacing within the cutouts shall not exceed 1.75 inches in width. 6. Maximum mesh size for chain link fences shall be a 1.25 inch square unless the fence is provided with slats fastened at the top or the bottom which reduced the openings to not more that 1.75 inches. 7. Where the barrier is composed of diagonal members, such as a lattice fence, the maximum opening formed by the diagonal members shall not be more than 1.75 inches. S. Access gates shall comply with the requirements of items 1 through 7, and shall be equipped to accommodate a locking device. Pedestrian access gates shall open outward away from the pool and shall be self- closing and have a self - latching device. Gates other than pedestrian access gates shall have a self - latching device. Where the release mechanism of the self - latching device is located less that 54 inches from the bottom of the gate, the release mechanism and openings shall comply with the following: a. The release mechanism shall be located on the pool side of the gate at least 3 inches below the top of the gate, and b. The gate and barrier shall have no opening greater than 0.5 inch within 18 inches of the release mechanism. 9. Where a wall of a dwelling serves as part of the barrier one of the following conditions shall be met: a. The pool shall be equipped with a powered safety cover in compliance with ASTM F 1346; or b. All doors with direct access to the pool through that wall shall be equipped with an alarm, which produces an audible warning when the door and its screen, if present, are opened. The alarm shall sound continuously for a minimum of 30 seconds immediately after the door is opened and be capable of being heard throughout the house during normal household activities. The alarm shall automatically reset under all conditions. The alarm system shall be equipped with a manual means, such as touch pad or switch, to temporarily deactivate the alarm for a single opening. Such deactivation shall last for not more than 15 seconds. The deactivation switch(es) shall be located at least 54 inches above the threshold of the door; or c. Other means of protection, such as self- closing doors with self - latching devices, which are approved by the governing body, shall be acceptable so long as the degree of protection afforded is not less that the protection afforded by Item a or b described above. 10. Where an aboveground pool structure is used as a barrier or where the barrier is mounted on top of the pool structure, and means of access is a ladder or steps, then; a The ladder or steps shall be capable of being secured, locked or removed to prevent access, or b. The ladder or steps shall be surrounded by a barrier which meets the requirements of Items 1 through 9. When the ladder or steps are secured, locked or removed, any opening created shall not allow the passage of a 4 inch- diameter sphere Indoor swimming pool. All walls surrounding an indoor swimming pool shall comply with Item 9. Prohibited Locations. Barriers shall be located so as to prohibit permanent structures, equipment or similar objects from being used to climb the barriers. Barrier exceptions. Spas or hot tubs with a safety cover which complies with ASTM F 1346 shall be exempt from the provisions of this appendix. I 1 l NC Department of Insurance Office of the State Fire Marshal - Engineering Division 1202 Mail Service Center, Raleigh, NC 27699 -1202 919 - 661 -5880 Swimming Pool Equipotential Bonding Grid VWO Code: 2005 Electrical Code Date: May 9, 2005 Section: 680.26 C Question: What is the requirement for an equipotential bonding grid around swimming pools? Answer: This question references a change in the 2005 State Electrical Code requiring that an equipotential bonding grid be established around the perimeter of the pool. Equipotential bonding grids and their use are not new to the Code, yet are new to Article 680. There is no change in the requirements for bonding metallic components of the pool under previous Code language. This new Section adds to those requirements by installing an equipotential bonding grid under the paved walking surfaces extending outward to a minimum of 3 feet and encompassing the top edge of the pool wall following the contour of that edge, still meeting the concept that all metallic sections or parts of the pool be bonded together to eliminate differences of "potential" between any metal components of the pool or surrounding conductive surfaces. This "grid" is manufactured by applying crisscrossed rebar, or minimum number 8 steel wire mesh, or a copper grid system comprised of minimum number 8 copper conductor installed in a uniformly spaced perpendicular grid pattern, placed between the earth and the concrete or within the concrete, with no insulating material separating the earth and concrete. The purpose is to assure a grounding plane by which stray voltage might have a more effective path to earth. NOTE: At this time there is a Tentative Interim Amendment, or TIA, being considered for the 2005 National Electrical Code, our State Electrical Code, to clarify this Section. Code Making Panel 17 had considered this during a specially called committee meeting in April due to misunderstandings of this Section. The TIA will reflect that the equipotential bonding grid was not intended to be required to follow the bottom or sides of a non - conductive pool, only to be developed in a minimum 3 feet wide pattern from the edge (contour) outward, under the concrete walking surface surrounding the pool. This is for clarification only and will not effect the original intent of Section 680.26. As stated, walls and floors of steel reinforced concrete or metal shall meet the bonding requirements of Section 680.26(B). Keywords: Swimming pool bonding