HomeMy WebLinkAboutPLM2002-01442.tif i i P.O. Box 389 PLUMBING — U Newton, NC 28658 / �� \ PERMIT Q f 1 Phone: (828)465-8399 v\ 1 Fax: (828)465 - 8962 PERMIT NO.: PLM2002 - 01442 / Web Site: www.co.catawba.nc.us. APPLIED: 09/23/2002 I8 a 2 Popular Pages / Online Permit Center ISSUED: 09/23/2002 EXPIRES: 03/23/2003 SITE ADDRESS: 2690 KELLY BLVD CLAREMONT NC ASSESSOR'S PARCEL NO.: 375111752857 TYPE OF WORK: ADDITIONS TYPE OF USE: STORAGE BUILDING SQ. FOOTAGE: st PHYSICAL DIRECTIONS: HWY 321 N/ FIT HWY 70 TOWARD CLAREMONT/ FIT INTO CLAREMONT INTERNATIONAL BUSINESS PARK/ @ STOP SIGN, FIT KELLY BLVD/ GO UP HILL, CR R R TRAC KS/ BLDG ON LE FT PROJECT DESCRIPTION: FIRE SPRINKLER PLANS (MEZZANINE ADDITION) OWNER /APPLICANT CONTRACTOR 1 CONTRACTOR 2 GULF STATES PAPER CORP CENTRAL CAROLINA SPRINKLER PO BOX 669 LINO 602 CONOVER NC 28613 SWT #6493 Plumbing Fixtures Fees Fixture Type Quantity Type By Date Amount FIRE SPRINKLER/ NEW CONST & PRMT TC 09/23/2002 $110.00 Total: $110.00 This permit is issued on the express condition that the above work shall conform in all respects to the statements certified to in the application for such permit, and that all work shall be done in accordance with all applicable zoning, building, electrical, plumbing and mechanical ordinances of the County of Catawba and the State of North Carolina. A permit issued for work under this Code shall expire by limitations six months after the date of issuance if the work authorized (FOOTINGS ARE CONSIDERED 1st INSPECTION ON NEW CONSTRUCTION) has not been commenced. If after commencement the work is discontunued for a period of 12 months, the permit therefore shall expire. * * *AN ADDITIONAL CHARGE OF $110.00 MAYBE ASSESSED FOR EACH UNWARRANTED INSPECTION SCHEDULED. ** * t If there are any questions, please contact the office between 8:00a m. and 5:00p.m. / / / County Building Inspe for (Inspector's Office Hours: 8:00 - 9:00 a.m. t x E . ( E (7041 465 -8399 Office Number CATAWBA �` COUNTY [ . ox ' (704) 465 -8962 Tax Number t } Newton. NC 28658 f 4r (Please print or type) !APPLICATION FOR PERMIT Date 9/16/02 Electrical Plumbing Mechanical X Fire Sprinkler Other (List) Building Permit # Property ID # Use of Structure INK Sly Physical Street Address 2690 IUGLY RM cL R mONT, NC 28610 Owner /Business ES PAPER CIORP Telephone ( 820 459 -8006 Address 2690 MT" RQA P n Bent CLAREMM NC 28610 City State Z+P Subcontractor CAL CAICLIM SEEM" S • I INC. - - - Telephone f7n 732 -3343 (N UstrJ .r. Ucmw bwkl Address 127 N0TZ P- BI]X 602 TT !ffi- NC 28092 License # t i; 'Ann PER City slate Lp CLASS I r 828 1464 -737 General Contractor MUM �• • INC, Telephone ( Location of Structure or Project (Physical Directions. Road Numbers and `Name. Etc.) i NW MAKE IUMM row FC, WA= °" TW ` cgAm INSIIE E PLAAN'P BUIIDING QJ P�27»�`PFR CF PRESS ROOM <.c•:: ;;:,�: }: .;: °:;�3:. .,• r ..' �,... ..r..;:x•i>'v':. ?.':..r... < .zxr ::V.r... :.... .. ... ... ..•: ..........r.. ..,:r..,... : +.x:' ;:: :..., :.:: ELECTRICAL Panel #1 Amps Panel #2 Amps Panel #3 Amps Panel #4 Anws New Panel Pole Service Wire Mechanical unit only (No Service Change) _ Sub Panel Service Change Interior wiring (No Service Change) Saw Service Load Control Other (list) Sign Service Mobile Home i *If more than one panel list size of each • TOTAL FEE S .:.,•..:.; .:.: { .:.:.:.. :.... :: • vv. vv.X:,i... a w:t %,... iv .. . ,n. •..,::+3:}•r:•s ? xLt.: ♦ : \:>.n..{:'X4:i:i.':Xv:4v.: Y.ti Y S:::vXrr. S,: vv .: v•v :: •.r •:::: •C h:.vnv: f. i. .... . .UMBING _ Total lumber of Full or Partial Bath /Toilet Rooms X Fire Sprinkler system (New /Addition) (Including ones for future use) Gas Line /Pressure 'Pest onhy Mobile home (new set -up only) Other (list) t Water Heater (Electric, Gas) t TOTAL FEE $ �Xr .. ... . � .. .. ..., .... .:uJ, ...: ... n. ,. ... .. ::ti �iKw... r.J .JGfi.:: •'•:: j{:. ' ti:{': MECHANICAL (Check One)_Ncw Installation ,_Change out existing system (additional wiring -NO /YES) is # Heat Pump or Furnace with A/C Water Heater (Electric. Gas) # Furnace (Oil. Gas. or Electric) Gas Line /Pressure Test R; # Air Conditioner Other (List) T Unit Heaters/ Gas logs t 'List number (#) of' units installed TOTAL FEE $ '" . "_..` ................:.... E charged .,•.„ + perniit." the "All fees entered by Inspection Department. DOUBLE FEZ for work started P nor to obtaining undersigned makes application for permits and inspection of work described agre to comply with all applicable Statr. County, codes and laws regulating the work. t 1 SIG NATli 1ZE i PIZ1Vt VA1b1E Rfl•)Gl�t D r T Tnric - irrnir i ni rr ► nmr i "App!lcxlivas cumplcLcJ uu[ uf 11-ru uIr ec b uut�trett tD�9 �ivt llavtttg a bllli�t6f ett cvuttl «tus+(' tiuLett��c rl• a Notary Public, do hereby certify that Personally appeared nt.. th day and aeltnowledged the due executiun of the foregoing instr+unclit. Witrieae VnN !►a and official seal. this the i G dzt► of _ N otary Public 1 °CENT CAROLINA SPRINKLER COMPANY INC P.O. 602 LINCOLNTON, N. C. 28092 704 - 732 -3343 COMPUTERIZED HYDRAULIC CALCULATIONS COVER SHEET FOR: GULF STATES PAPER CORP. "MAKE READY ROOM" ADDRESS: CLAREMONT , N.C. DATE: 09 -16 -02 JOB # 0253 c CONSTRUCTION: NON - COMBUSTIBLE OCCUPANCY: WATER -BASED INK DESIGN CRITERIA F. M. GLOBAL RECOMMENDATION WET SYSTEM 100 SQ. FT. PER SPRINKLER %z " ORIFICE SPKLR'S K- FACTOR 5.6 TEMP. RATING 286 DEGREE F.. THIS SPRINKLER SYSTEM WILL DELIVER A DENSITY OF .15 G.P.M.PER SQ. FT. FOR THE MOST REMOTE 3000 SQ. FT. AREA WHEN FLOWING 542.91 GPM AT A PRESURE OF 69.42 psi AT THE BASE OF THE RISER INSIDE HOSE 0 gpm OUTSIDE HOSE 250 gpm RACK SPKLR'S .0 gpm WATER SUPPLY DATA WATER FLOW TEST FIRE PUMP PERFORMANCE TEST * * * * * * * * * * * * * * * * * * * * ** DATE OF TEST: TIME OF TEST STATIC (psi) 152 RESIDUAL (psi) 130 FLOW (gpm) 1500 ELEV. OF RESIDUAL TEST GAGE: -7.0 FT. LOCATION OF FLOW TEST: EXISTING 1250 GPM @ 75 PSI FIRE BOOSTER PUMP z' TEST CONDUCTED BY: C.C.S.C. & F.M. 1 TEST DATA FURNISHED BY: C.C.S.C. & F.M. ( GENERAL REMARKS: HYDRAULIC DESIGN BASED ON EXISTING 1250 GPM @ 75 PSI FIRE BOOSTER PUMP TEST - - - -- -TEST RESULTS REDUCED 10% FOR HYDRAULIC CALCULATIONS.. g f; E CENTRAL CAROLINA SPRINKLER CO. INC.. PHONE 704 732 3343 FAX 704 735 2991 I GULF STATES " MAKE READY ROOM " CLAREMONT,NC # 0253 PAGE 1 SPRINKLER SYSTEM ANALYSIS TO SHOW THE MAXIMUM DENSITY AVAILABLE WITH ZERO PRESSURE REMAINING THE FOLLOWING SPRINKLERS ARE OPERATING IN: ( ] TEST AREA 1 [ ] TEST AREA 2 [ ] TEST AREA 3 [ {/REMOTE AREA Elevation of sprinklers = Elevation above water test. REF. PT. K ELEV. FLOW PRESSURE ft gpm psi 101 5.60 18.70 34.04 36.95 102 5.60 18.70 33.68 36.16 103 5.60 18.70 31.74 32.12 104 5.60 18.70 31.40 31.43 105 5.60 18.70 29.69 28.10 106 5.60 18.70 29.36 27.49 107 5.60 18.70 27.88 24.77 108 5.60 18.70 27.57 24.23 109 5.60 18.70 26.29 22.04 110 5.60 18.70 25.99 21.53 111 5.60 18.70 24.91 19.79 112 5.60 18.70 24.62 19.32 113 5.60 18.70 23.74 17.96 114 5.60 18.70 23.44 17.52 ON 5 5.60 18.70 22.75 16.50 6 5.60 18.70 22.46 16.08 117 5.60 18.70 21.94 15.35 118 5.60 18.70 21.66 14.95 119 5.60 18.70 21.31 14.48 120 5.60 18.70 21.04 14.12 121 5.60 18.70 20.86 13.88 122 5.60 18.70 20.61 13.54 123 5.60 18.70 20.58 13.51 124 5.60 18.70 20.35 13.20 125 5.60 18.70 20.45 13.33 126 5.60 18.70 20.23 13.05 127 5.60 18.70 20.43 13.31 128 5.60 18.70 20.22 13.04 129 5.60 18.70 20.48 13.38 130 5.60 18.70 20.28 13.11 THE SPRINKLER SYSTEM FLOW IS 729.99 gpm THE OUTSIDE HOSE FLOW AT REFERENCE POINT N0. 1 IS 0.00 gpm [ ] THE INSIDE HOSE [ ] RACK SPKLR'S. [ ] YARD HYDT. FLOW IS 250.00 gpm 6' i E c CENTRAL CAROLINA SPRINKLER CO. INC.. PHONE 704 732 3343 FAX 704 735 2991 GULF STATES MAKE READY ROOM " CLAREMONT,NC # 0253 PAGE 2 TINIMUM 202 /sq. N ft. NNNNNNNNNNNNNNNN V THE FOLLOWING PRESSURES & FLOWS OCCUR - - -> AT REF. PT. 1 < - -- STATIC PRESSURE 137.00 psi RESIDUAL PRESSURE 117.00 psi AT 1500.00 gpm TOTAL SYSTEM FLOW 979.99 gpm AVAILABLE PRESSURE 127.91 psi AT 979.99 gpm OPERATING PRESSURE 127.91 psi AT 979.99 gpm PRESSURE REMAINING 0.00 psi AWN APON E E k tr `s s CENTRAL CAROLINA SPRINKLER CO. INC.. PHONE 704 732 3343 FAX 704 735 2991 GULF STATES " MAKE READY ROOM " CLAREMONT,NC # 0253 PAGE 3 M NhryhNryNNNNNNNNNMNNNNNNNNNNNNNNNNNNNNNNMNNNNNNNNNN HYDRAULIC CALCULATIONS AT SPECIFIED DENSITY THE FOLLOWING SPRINKLERS ARE OPERATING IN: [ ] TEST AREA 1 [ ] TEST AREA 2 [ ] TEST AREA 3 [ k / REMOTE AREA Elevation of sprinklers = Elevation above water test. REF. PT. K ELEV. FLOW PRESSURE ft gpm psi 101 5.60 18.70 25.64 20.96 102 5.60 18.70 25.32 20.44 103 5.60 18.70 23.75 17.99 104 5.60 18.70 23.47 17.56 105 5.60 18.70 22.10 15.57 106 5.60 18.70 21.85 15.22 107 5.60 18.70 20.67 13.62 108 5.60 18.70 20.44 13.32 109 5.60 18.70 19.45 12.06 110 5.60 18.70 19.24 11.80 ill 5.60 18.70 18.42 10.82 112 5.60 18.70 18.23 10.59 113 5.60 18.70 17.57 9.85 114 5.60 18.70 17.38 9.63 115 5.60 18.70 16.87 9.08 16 5.60 18.70 16.68 8.87 7 5.60 18.70 16.31 8.48 8 5.60 18.70 16.11 8.28 119 5.60 18.70 15.87 8.03 120 5.60 18.70 15.67 7.83 121 5.60 18.70 15.54 7.70 122 5.60 18.70 15.34 7.50 123 5.60 18.70 15.31 7.47 124 5.60 18.70 15.12 7.29 125 5.60 18.70 15.18 7.35 126 5.60 18.70 15.00 7.17 127 5.60 18.70 15.13 7.30 128 5.60 18.70 15.03 7.20 129 5.60 18.70 15.21 7.37 130 5.60 18.70 15.01 7.19 THE SPRINKLER SYSTEM FLOW IS 542.91 gpm THE OUTSIDE HOSE FLOW AT REFERENCE POINT N0. 1 IS 0.00 gpm [ ] THE INSIDE HOSE [ ] RACK SPKLR'S. [ ] YARD HYDT. FLOW IS 250.00 gpm r e CENTRAL CAROLINA SPRINKLER CO. INC.. PHONE 704 732 3343 FAX 704 735 2991 GULF STATES " MAKE READY ROOM " CLAREMONT,NC # 0253 PAGE 4 ---------------------------- ----------------------- - - ------- ----- --- -------- T INIMUM DENSITY PROVIDED BY THIS SYSTEM IS 0. 150 - Pm /sq. THE FOLLOWING PRESSURES & FLOWS OCCUR - - -> AT REF. PT. 1 < - -- STATIC PRESSURE 137.00 psi RESIDUAL PRESSURE 117.00 psi AT 1500.00 gpm TOTAL SYSTEM FLOW 792.91 gpm AVAILABLE PRESSURE 130.86 psi AT 792.91 gpm OPERATING PRESSURE 77.60 psi AT 792.91 gpm PRESSURE REMAINING 53.26 psi 4' p E CENTRAL CAROLINA SPRINKLER CO. INC.. PHONE 704 732 3343 FAX 704 735 2991 GULF STATES " MAKE READY ROOM " CLAREMONT,NC # 0253 v PAGE 5 N ~~~~~~~~~~~~~ FITTING N Equivalent N Length N per N NFPA N 13 N 1994, 6- 4.3 ~~~~~~~~~~~~ ~~~~~~~~~H~~~~ ' -' Indicates Equivalent Length. 'T' Indicates Threaded Fitting 1 =45 Elbow, 2 =90 Elbow, 3 ='T' /Cross, 4= Butterfly Valve, 5 =Gate Valve, 6 =Swing Check Valve ----------------------- ----------- FROM TO FLOW PIPE FITS EQV. H -W PIPE DIA. FRIC. ELEV. FROM TO DIFF (gpm) (ft) (ft) C TYPE (in) (psi) (psi) (psi) (psi) (psi) 1 2 792.91 7.00 2256 83.25 120 2 8.249 0.005 0.000 77.60 77.14 0.46 2 3 792.91 365.00 2 19.65 150 107 7.980 0.004 0.000 77.14 75.60 1.54 3 4 792.91 640.00 235 78.61 150 107 7.980 0.004 1.517 75.60 71.21 2.87 4 10 542.91 58.00 23 63.86 140 101 7.980 0.002 1.517 71.21 69.42 0.27 10 11 542.91 22.25 56 43.93 120 2 6.357 0.009 5.070 69.42 63.75 0.60 11 12 542.91 165.50 22 25.10 120 2 6.357 0.009 0.000 63.75 62.13 1.62 12 13 542.91 44.80 223 34.78 120 12 3.340 0.208 0.000 62.13 45.54 16.59 13 14 542.91 16.50 2222 30.24 120 12 3.340 0.208 0.000 45.54 35.79 9.74 14 15 542.91 5.75 2 7.56 120 12 3.340 0.208 0.000 35.79 33.02 2.77 15 16 269.89 12.50 0 0.00 120 12 3.340 0.057 0.000 33.02 32.25 0.77 15 20 273.02 0.92 3 12.24 120 12 2.227 0.420 0.000 33.02 27.49 5.53 16 21 269.89 0.92 3 12.24 120 12 2.227 0.411 0.000 32.25 26.83 5.41 20 101 273.02 3.30 3 12.24 120 12 2.227 0.420 0.000 27.49 20.96 6.53 21 102 269.89 3.30 3 12.24 120 12 2.227 0.411 0.000 26.83 20.44 6.39 101 103 247.38 8.00 0 0.00 120 12 2.227 0.350 0.000 20.96 17.99 2.97 102 104 244.57 8.00 0 0.00 120 12 2.227 0.343 0.000 20.44 17.56 2.88 103 105 223.63 8.00 0 0.00 120 12 2.227 0.290 0.000 17.99 15.57 2.42 104 106 221.10 8.00 0 0.00 120 12 2.227 0.284 0.000 17.56 15.22 2.35 105 107 201.53 8.00 0 0.00 120 12 2.227 0.239 0.000 15.57 13.62 1.95 10 108 199.25 8.00 0 0.00 120 12 2.227 0.234 0.000 15.22 13.32 1.89 1 ';09 180.87 8.00 0 0.00 120 12 2.227 0.196 0.000 13.62 12.06 1.56 10 178.81 8.00 0 0.00 120 12 2.227 0.192 0.000 13.32 11.80 1.52 109 111 161.42 8.00 0 0.00 120 12 2.227 0.159 0.000 12.06 10.82 1.24 110 112 159.57 8.00 0 0.00 120 12 2.227 0.155 0.000 11.80 10.59 1.21 111 113 142.99 8.00 0 0.00 120 12 2.227 0.127 0.000 10.82 9.85 0.98 112 114 141.34 8.00 0 0.00 120 12 2.227 0.124 0.000 10.59 9.63 0.96 113 115 125.42 8.00 0 0.00 120 12 2.227 0.099 0.000 9.85 9.08 0.77 114 116 123.96 8.00 0 0.00 120 12 2.227 0.097 0.000 9.63 8.87 0.76 115 117 108.55 8.00 0 0.00 120 12 2.227 0.076 0.000 9.08 8.48 0.60 116 118 107.28 8.00 0 0.00 120 12 2.227 0.074 0.000 8.87 8.28 0.59 117 119 92.23 8.00 0 0.00 120 12 2.227 0.056 0.000 8.48 8.03 0.45 118 120 91.17 8.00 0 0.00 120 12 2.227 0.055 0.000 8.28 7.83 0.45 119 121 76.36 8.00 0 0.00 120 12 2.227 0.040 0.000 8.03 7.70 0.33 120 122 75.50 8.00 0 0.00 120 12 2.227 0.039 0.000 7.83 7.50 0.33 121 123 60.83 8.00 0 0.00 120 12 2.227 0.026 0.000 7.70 7.47 0.22 122 124 60.16 8.00 0 0.00 120 12 2.227 0.026 0.000 7.50 7.29 0.22 123 125 45.52 8.00 0 0.00 120 12 2.227 0.015 0.000 7.47 7.35 0.13 124 126 45.04 8.00 0 0.00 120 12 2.227 0.015 0.000 7.29 7.17 0.12 125 127 30.34 8.00 0 0.00 120 12 2.227 0.007 0.000 7.35 7.30 0.05 126 128 30.04 8.00 0 0.00 120 12 2.227 0.007 0.000 7.17 7.20 -0.03 127 129 15.21 8.00 0 0.00 120 12 2.227 0.002 0.000 7.30 7.37 -0.07 { f { 6 CENTRAL CAROLINA SPRINKLER CO. INC.. PHONE 704 732 3343 FAX 704 735 2991 GULF STATES " MAKE READY ROOM " CLAREMONT,NC # 0253 PAGE 6 4 N - - - N H - - - - - - ti - - - - - - - - H H - - - - - - - - - - - - - - ti N N FITTING N Equivalent N Length N per N NFPA N 13 N 1994, N 6 -4.3 ' -' Indicates Equivalent Length. 'T' Indicates Threaded Fitting 1 =45 Elbow, 2 =90 Elbow, 3 ='T' /Cross, 4= Butterfly Valve, 5 =Gate Valve, 6 =Swing Check Valve --------------------------------------------------------------------------------------- - - - - -- _ FROM TO FLOW PIPE FITS EQV. H -W PIPE DIA. FRIC. ELEV. FROM TO DIFF (gpm) (ft) (ft) C TYPE (in) (psi) (psi) (psi) (psi) (psi) 128 130 15.01 8.00 0 0.00 120 12 2.227 0.002 0.000 7.20 7.19 0.01 A MAX. VELOCITY OF 22.48 ft. /sec. OCCURS BETWEEN REF. PT. 20 AND 101 Sprinkler -CALC Release 7.2 Win By Walsh Engineering Inc. North Kingstown R.I. U.S.A. AWN t g CENTRAL CAROLINA SPRINKLER CO. INC.. PHONE 704 732 3343 FAX 704 735 2991 127 MOTZ AVE. LINCOLNTON N.C. 28092 H Y D R A U L I C C A L C U L A T I O N S C 0 V E R S H E E T GULF STATES MAKE READY ROOM " CLAREMONT,NC # 0253 W A T E R S U P P L Y STATIC PRESSURE (psi) 137 RESIDUAL PRESSURE (psi) 117 RESIDUAL FLOW (gpm) 1500 B O O S T E R P U M P S NUMBER OF BOOSTER PUMPS 0 i S P R I N K L E R S MAXIMUM SPACING OF SPRINKLERS (ft) 8 MAXIMUM SPACING OF SPRINKLER LINES (ft) 12.5 SPECIFIED DISCHARGE DENSITY (gpm /sq. ft.) .15— THIS SPRINKLER SYSTEM WILL DELIVER A DENSITY OF .15 gpm /sq. ft. FOR A DESIGN AREA OF 3000 SQ. FT. OF FLOOR AREA THIS SYSTEM OPERATES AT A FLOW OF 542.91 gpm AT A PRESSURE OF 69.42 psi THE BASE OF THE RISER (REF. PT. 10) PIPES USED FOR THIS SYSTEM 002 SCHEDULE 10 107 PVC BLUE BRUTE (150) 101 CAST IRON CEMENT LINED (150) 012 DYNA -FLOW 10 ( f r ( i r "s t. WATER SUPPLY/DEMAND GRAPH GULF STATES " MAKE READY ROOM " CLAREMONTAC # 0253 150.E 140.00 130.00 120.00 P 110.00 R 100.00 E 90.00 S 80.00 S 70.00 U 60.00 R 50.00 _ E 40.00 30.00 20.00 10.00 0.00 0 500 1000 1500 2000 Supply: 117.00 psi @ 1500.00 gpm FLOW I d e g F P E.