HomeMy WebLinkAboutAUTH-5-11-18431.TIF `a qA CATAWBA COUNTY Case # AUTi-I-5-11-18431
Q . 2 Pubiic Health Department Subdivision
¢ Environmental Health Division C} COURT
¢" Co `<' PO Box 389, 100-A Southwest I�Ivd, Newton, NC 286�8 Lot # 44
tg 2 �w PIN# 376303048��6
Applicant/Owner Tina Little
Site Address: 3075 SUNSET DR, ClaremonL NC
Property Size: SF 0.759 ACRES
D irections: ROCK I3ARN RD/ LF SUNSLT DR/ I 50 YARDS ON LEF"I'
Authorization to Construct Permit
Authorization to Construct Wastewater System (Required for Building Permit�
* See site plan and nwnber of additronal attacM��ents (�.
Proposed Wastewater System: 25% REDUCTION Wastewater Flow 485 g.p.d
Type: II - OTHER NON-CO TRENCH S Y S TEMS
Soil LTAR: • g.p.d./ft2
Permit Category: Expansion
Type of Facility: Primary Residence
Basement? Yes Basement Plumbing? Yes Bedrooms: 3
Wastewater System Requirements
Tank Size: Existing Tank 1,000 gal Pump Tank gal Grease Trap gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 1,341 sq ft Total Length: 105 ft Maximum Trench Depth ' in
Aggregate Depth in Trench Width '�� ft
Minimum Soil Cover 6 � 0 in Minimum Trench Separation 9 � 0 ft on center
Number of Drain Lines 5
Distribution: Serial
Additional Specifications: Adding l OS to existing drainfield to accommodate a 1 chair beauty shop addition.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved,
and may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
»»> DO NOT INSTALL SYSTEM UNDER WET CONDITIONS ««<
Proposed Repair
System Class: IIIB Proposed System: 50% REDUCTION Distribution Type:: Pressure Manifold
Soil LTAR: •� g.p.d./ft2
PUMP REOUIRED
OS/31/I 1 09:3�
��,A CATAWBA COUNTY Case # AU"['H-�-11-18431
y � Public Health Department
Q,� � 2 Subdivision CI COURT
_ Environmental F[ealth Division
o� '< PO Box 389, 100-A Southwest Blvd, Newton, NC 286>8 Lot # 44
I $ 2 �" �'�N# 376303048�56
Applicant/Owner T1na L,lttle
Site Address: 3075 SUNSGT DR, Claremont, NC
Property Size: SF 0.759 ACRES
Directions: ROCK BARN RD/ LF SUNSET DR/ 150 YARDS ON LEFT
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the
applicanUproperty owner to insure that all Cata�vba County Planning/Zoning and Building Inspections requirements are met. This
Authorization to Construct Permit is subject to revocation if the site plan, plat or the intended use changes, or if site conditions are
altered. The Authorization to Construct Permit is not affected by a change in ownership of the property. This permit was issued in
compliance with the provisions of the North Carolina 'Lrnvs and Rule�for Sewn�e TrenUttenl an�! Dispos�d Svstems' (15A NCAC 18A
.1900). Neither Catawba County nor the Environmental Health Specialist warr�nts that the septic tank system will continue to
function satisfactorily for any given period of time.
Susan Bumgarner OS/30/2011
AUTHORI7ED STATE AG�NT APPROVAL DATE
Permit Expiration Date: OS/28/2016
No grading or construction activiry rs allowed in areas designated for systen7 and repnir without npproval of the Health Depnrtment.
OS/31/11 09:3�