Loading...
HomeMy WebLinkAboutCBPR-3-11-9979 ARCHITECT COMMENTS .tif ' ECT 6 PLANNER �� r ARCHITECT P. O. Drawer 1787, Hickory, North Carolina 28603 May 18, 2011 nn Catawba County Plan Review l) 76 North Center Street D Hickory NC 28601 MAY 1 $ 2011 Ref: Alterations, First Baptist Church Hickory, NC a Gentlemen: This is written in responce to your plan review comments in April. { Building Review: 1 ' 2. Firewalls have been identified on Part Plans "A" and "B" on sheet #3. Elevator shaft walls,Stairwell walls and interior Boiler Room walls are Two (2) hour construction except where Stairwells #3 and #5 are adjacent to the 4 Hour rated Firewalls.on one side. 3. Complied with. See Door Schedule, Sheet No.3. 4. Complied with. See Door Schedules and letter from Mr. Carl Martin, Code consultant. 5. Complied with. See Door Schedule. 6. Complied with. See door Schedule. 7. Complied with. See "General Notes" on Sheet No. 3. 8. See Plan "C ". Emergency lighting,strobe light /alarm, exit lights are shown .3 here. All of the other corridors are similarly equipp x 9. See Plan "C ". Checked by H /AC Contractor. Supply;;& Return grilles , in ea.Rm. Fire Department Review Since this was "Approved with notes ", We will be sure that the Owners are made aware of these items. Also, See the revised plans for changes and omission of some doors take care of some of the comments. 3 Very truly yours, 4 U I FO���GL Robert L. Clark, AIA RLC/cc NOTE: See attached letter from Mr. Carl Martin, Code Consultant, Insurance Dept. regarding door ratings. RESUBMITTAL Robert L. Clark, AIA • Member: American Institute of Architects i' NORTH CAROLINA ✓ DEPARTMENT OF INSURANCE Engineering OOSFM x Wayne G oodwin ! Commissioner of Insurance 77m Bradley I Assistan. t State Fire Marshal Apr# 27, 2011 Mr. Robert Cla*, AIA UINFOUR DESIGN P.O. Box Drawer 1781 Hickory, NC 28603 ' 'RE: Renovations to NMI Baptist Church, Hickory, NC F. F Dear Mr. Clark: This letter is in response to your fax dated 4/20111 (attachment 'A") r acuestinry a code interpretation for the above mentioned project. With that fax were tyw) non-scale copies of piopcssed floor plans °? You had two questions: ��• 1) Can you place a 3 -hour fire- resiMence -•ated door wrath 3 -hour rated giaring in an e;.ist :ng 3 -hour fire- resistance4ated fire wa0 2) Does the addition of doers across a rated coridor tc divide 'he corridor into separate sect fns need to he 20 minute fire resistance - rated? i i My conclusions are: 1) Table 715.4 of the 2009 NC Building Code (NCBC) indicates that a 3 -hour door is acceptable in a 3 -hour Fire wall. Section 715.5 - F1re- Protectlor -Rated Gtazi. ^5 indicates that compliance with Sect on 795.4.5 is required for the glazing. Section 715.4.6.1 - Size Limitations indicates ii Exception #1 that "Fire - F7h.t6ctior -rated gla7irxg i r, Are doors l ocated in fire walls S hari be prohiNted except 'hat v ihere. serving as a '7orizoiafal exit, a se,Yclasiny swix�irg door .shat! be , :yen. niltcd tv have P vision panet o` lint . ore than 100 cquars inches without a rlirrension exceeding 10 inches" Only such doors t ^at are used as a horizontal exit: as described in Section , '022 Tray have glazing and then the size is fmited to In0 s;uare inches. 2 The cote does not indicate a requirement for a rated door in a .%rrri jor %vhere t ie rloor i- usec' ar ly to 7 - subdivide the corridor into sections. As lo ng as the corridor cor; Is Xll irIUCLS on either aide of the door then the door may be unrated. I trust this addresses your concerns. If I can be of further assistance. do not hesitate to contact Me. Sin Iy; Carl P. Martin Chief B&jWing Code Consultant carl.martlr@ncdol.gov CPMibs1 cc: Barry r3upton. Chief Code Consuitant, IDS FNM-Engineering Division City of Hickory Building Inspections a PA.:, Sop- 114L!= r ']ic, Pa;elgh, NC 276 9P_!?02 » 7 .• ! C '6 C . An Equal Opportunity Employer C o