HomeMy WebLinkAboutCBPR-11-10-8432 ARCHITECT COMMENTS.tif 3 A R C H I T E C T .v� `J R.- F i x January 19, 2011 i Steve Deitz I Catawba County Plan Review 76 N. Center Street i Hickory, NC 278601 Re. Hickory Green Apartments #BLDG -11 -10 -13081 s f F Mr. Deitz, The Developer /Owner of this project proposes to install NFPA 13R fire sprinkler systems in each of the 5 apartment buildings while constructing the stairs as unenclosed vertical means of egress. Therefore we hereby request approval to use the exception to 1007.3 of the NCSBC which became effective January 1, 2011. Our drawings will be resubmitted showing NFPA 13R sprinklers specified in Appendix B for the residential buildings. ti t ` 54t CAl' °` Respectfully, ti ��t� CAR 61— a ,.....• lej 23 Z � N A. Wayland Plaster Architect ` � AWP /poh Copy to Hickory Green, LLC 252 FIRST AVENUE NW HICKORY, NC 28601 PHONE 828- 328 -4902 FAX: 828 - 328 -5987 nwaarch @earthlink net 1/- i0 16 31 93 ® $3 Z a a 33 3 .. A R .. C H I I T E C T.��U .. E _.-__. �M. . �..�...,��,n..w..�,.�.t�.�... -. �3Ci Sq3 Z January 27, 2011 � � � 2 tl�ls 01 Steve Deitz MAY 1 � 2011 Catawba County Plan Review 76 N. Center Street FR Hickory, NC 28601 Re. Hickory Green Apartments #BLDG -11 -10 -13081 Mr. Deitz, We have completed our revisions and replies to your reviews of our drawings for this project. We are resubmitting the drawings with the following comments: Item no.: 2. Sheet T1.2: Request to use exception to 1007.3 is submitted herewith. 3. Sheet T1.2: Allowable area has been corrected. 4. Sheet T1.2: The "R" value for the doors has been corrected. 5. Sheet T1.3: See Item 2 6. Sheet T1.3: See Item 3 7. Sheet T1.3: See Item 4 8. Sheet T1.5: Occupancy is corrected. 9. Sheet T1.5: Seating layout is shown on sheet A1.14. 10. Sheet T1.6: This building will not have fire sprinklers. 11. Sheet T1.6: The occupancy type has been corrected. 12. The pool and deck are to be designed by the pool contractor at a later date. However the Clubhouse restrooms will accommodate up to 240 people (120 women, 225 men) which is above adequate for this project. The Clubhouse, Pool, Poolhouse complex has 2 accessible parking spaces 252 FIRS - I AVENUE NW HICKORY, NC 28601 PHONF 828- 328 -4902 FAX: 828 - 328 5987 c, ^'faalch @earthlink.net located at the front of the Clubhouse. Access to the Pool and Poolhouse is from the front along sidewalks beside the Clubhouse. Stairs at rear of I Poolhouse are for service entrances. 12 -15. Refer to Civil Engineer's letter. 16. Sheet A1.2: Alignment of load- bearing walls with footings has been checked and verified. 17. Sheets A1.3 thru A1.9: Hatching and plan key have been added to clearly indicate load- bearing walls. 18. Sheet A1.10: Ceiling access panel is specified to be'/ hour rated with closer and latch. 19. Sheet A1.10: Smoke partition openings are specified to be automatic closing with positive latching. 20. Sheet A1.10: See item 2. 21. Sheet A1.12: There are 4 dryers shown. These are to be commercial electric units. 22. Sheet A1.12: An accessible pull -out section has been added at the kitchen /bar area. 23. Sheet A1.12: Accessibility of the mailboxes is noted and called out in the specifications. 24. Sheet A1.14: In lieu of a section of the bar, an accessible table is designated. 25. Sheet A1.14: Layout of tables and chairs is shown. 26. Sheet A1.14: A "T" shaped turning area is shown behind the bar. 27. Sheet A1.15: A draft stop has been added in the attic. 28. Sheet A1.15: Self closing and latching are specified. 29. Sheet A1.15: A van - accessible space in the garage building is shown. The door is 9'w x 8'h. 30. Sheet A2.6: Elevation revised. 31. Sheet A3.2: Spacing of weeps has been corrected. 32. Sheet A3.3: A detail showing anchoring of balcony framing to wall is shown. 252 FIRST AVENUE NW HICKORY, NC 28601 PHONE: 828 -328 -4902 FAX: 828 328 5987 nwaarch @earthlink.ne? 3 a . 3 p t 4 q 3 33. Sheet A3.3: Fireblocking is shown in section 1/A3.3. 34. Sheet A3.7: An accessible section is shown at the bar. 35. Sheet A4.1: Installation of grab bars is not required in Type A units per 604.5 exception 3 of ANSI A117.1 2003. However blocking is required for future installation. 36. Sheet A4.1: No roll -in showers are required. Table 1107.6.1.1 is not applicable to R2 occupancies. 37. Sheet A4.1: All unit types are shown and detailed here. All are named and designated on the building plans. It is not necessary to draw each unit plan opposite hand per our meeting on 12/29/10. 38. Sheet A4.2: Our engineer advises that sufficient space for access to the water heater is provided by moving the washer forward. 39, 40, 41. Sheets A4.2, A4.3, A4.4: Adjustments have been made to the unit plans to allow compliance with clear floor space requirements of ANSI A117.1 2003 section 611.2. 42. Sheet A8.1: Detail 2/A8.1 has been expanded to show a typical stair tread. The riser heights are specified in the vertical floor -to -floor dimensions at the right side of the section. 44 -59. See engineers' letter attached. 60. The NCBC edition has been changed to 2009. 61. Fire sprinklers are not required in the attic areas in NFPA 13R systems. The Clubhouse, Poolhouse and Garage Building are not sprinklered. 62. The apartment units are R2 use classification and no fully accessible units are required. All first floor units are Type A or Type B units. According to ANSI A117.1 2003 section 1003, Type A units had been called the adaptable dwelling unit in the A 117.1 editions prior to 1998. When Type B units were added, the name of this type unit was changed to Type A. Therefore we are showing pull -out work surfaces in the kitchens of Type A units. Hickory Fire Department Review 1, 2. Hydrant flow tests will be performed after installation of new water lines and hydrants. 3. Noted 4. See response of Civil Engineer. 252 FIRST AVENUE NW HICKORY, NC 28601 PHONE: 828 -328 -4902 FAX: 828- 328 -5987 nwaarc1- c earthi nk_ net 3 a 5 -7. Comments noted. 8. Areas of refuge not required. See note no. 2 of the Building Department Review. t 9. General notes acknowledged. E Fire extinguishers are to be provided at locations directed by the Fire Official. Allow for 1 at each floor of each apartment building, 2 for the Clubhouse and 1 for the Poolhouse. See specifications. I believe we and our engineers have covered all the issues of the review and made appropriate corrections to the drawings. Please contact me if you have any questions. Respectfully, A. Wayland Plaster s G y Architect ~ v r •' Ly , ,. • AWP /poh Copy to Hickory Green, LLC 252 FIRST AVENUE NW HICKORY, NC 28601 PHONE: 828- 328 -4902 FAX: 828 - 328 -5987 nwaarch @earthlink net s GEORGE O. BROWN & ASSOCIATES, PLLC P.O. BOX 3423 CONSULTING ENGINEERS HICKORY, NC 28603 OFFICE (828) 324 -4002 FAX (828) 324 -4012 i s January 24, 2011 Northwest Associates Architecture 252 First Avenue, N.W. Hickory, N.C. 28601 Attn: Wayland Plaster, Architect Subject: PERMIT # BLDC -11 -10 -13081 HICKORY GREEN APARTMENTS Hickory, N.C. Dear Wayland: This letter is in response to plan review comments dated 12/08/10 and is numbered in sequence with those comments. Item 44: Sheet PI: Note referencing water hammer arrestors placed on Contract Drawing Sheet P1. Item 45: Spec's. Remove reference to polyvinyl chloride pipe. Use specifications listed on Sheet PI. Item 46: Spec's. Remove reference to service lateral pipe and fittings. Use specifications listed on Sheet PI> Item 47: Sheet P15: Gas piping shown to be Schedule 40 black steel. Item 48: Sheet P16: Shows Pool House drain/waste and vent piping in Item 49: Sheet M6: Fire damper shown at supply in bathroom off hall. Item 50: Sheet M8: CEF -2 exhaust capacity increased to reqwirements of 2009 NCMC Table 403.3. Item 51: Sheet M8: Cleanout shown for dryer per 2009 NCMC 504.3. Item 52: Sheet M8: Two (2) stack dryers for a total of four (4) dryers shown on plan. Item 53: Sheet M8: Stack dryers are electric. Also, gas water heaters are closed combustion. Therefore, no Combustion air required. Sincerely, GEORGE O. BROWN, P.E. GOB /jb a , a ALLIED Consulting Engineers i January 24, 2011 Northwest Associates Architecture 252 First Avenue, N.W. Hickory, N.C. 28601 Attn: Wayland Plaster, Architect Re: PERMIT # BLDC-1 1 -10-13081 HICKORY GREEN APARTMENTS Hickory, N.C. Allied #10220 Dear Wayland, This letter is in response to plan review comments dated 12/08/10 and is numbered in sequence with those comments. Electrical Comments: Item 54: Typical for all units: Visible and audible alarms are provided in each unit. A note was added to the fire alarm riser confirming that each panel will be provided with enough capacity for visual devices in every room per ICC A117.1. Item 55: Sheet E10: Smoke detectors are now indicated. Item 56: Sheet E13: Note to verify that two bulbs are being provided in each LED fixture, each LED fixture contains anywhere from 12 to 24 bulbs depending on the manufacturer. Item 57: Sheet E16: All service conductors are copper per sheet El, Part 3 of the specifications, note A. Item 58: Sheet E16: Services noted were updated to 800A each. Item 59: Sheet E16: Sheet E16 was revised so the drawing title is now Building #2. Sprinkler System Comments: Item 5: Sheet E13, the fire alarm riser was updated to add a temperature sensor that reports a trouble signal to the fire alarm panel. Allied Consulting Engineers, PLLC 4340 Taggart Creek Road, Suite D, Charlotte, NC 28208 Phone: (704) 399 -3943 Fax: (704) 394 -5648 www.allied-engineers.com J:\2010 \10220 Hickory Green Apts \Dots \commnet reponses 1- 24- 11.doc ( —L 405 South Sterling Street, Morganton NC 28655 828 43-' 5661 +ar 828 433 5662 T infoCwest- consuitants.com COfwSURAN TS PI!C January 26, 20100 Mr. Wayland Plaster Northwest Associates Architecture PI,LC 252 First Avenue NW Hickory, North Carolina 28601 i RE: Hickory Green Apartments Response to Building Inspections Review Comments West Consultants Project Number: 08162 Dear Mr. Plaster: Listed below, please find our response to the civil questions of the plan review comments of the referenced project performed by Catawba County Plan Review on December 6, 2010: Item 12: Please see Sheet C 1.2. The pool area has been hatched to show full extent of sidewalks and concrete areas along with dimensions. Fence is identified as 48" vinyl coated chain link with hot dip galvanized hardware and 4 -foot gates. Top and bottom wall elevations for retaining walls are shown on sheet C 1.4 (Grading and Drainage Plan). Contractor will be responsible for providing retaining wall design prepared by an NC professional engineer and for providing special inspections as referenced on Dote 9. Item 13: See Sheet C 1.2: See 4' x 8' pad for pool equipment. Item 14: See Sheet C 1.2. Sidewalks have been extended from all pool house entrances to pool area and adjoining sidewalk. Item 15: See Sheet C 1.4 for storm drainage layout. All storm drain pipes are to be I IDPE plastic pipe or reinforced concrete as shown on the pipe schedule. We are submitting revised PDF's by email of the updated plan set for your submission to the City of Hickory. Please contact our office at 828 -433 -5331 or email at ski ��_c t con ultanl .aim �� ith any questions or comments. Sincerely, WEST CONSULTANTS. PLLp Sam King, Jr.. I'E. PL�S� � i i 3 1