HomeMy WebLinkAboutp_1_rCBSA Architects `. Arcldfecturc � PISYYfng• ZnYCrfnr Dosfgn www.obee- erchitects.com GENERAL PLUMBING SPECIFICATIONS CAST IRON SOIL WASTE AND VENT PIPING: WASTE PIPING 2 INCH AND LARGER AND VENT PIPING 3 INCH AND LARGER SHALL BE STANDARD WEIGHT GASKETED CAST IRON, SMALLER SHALL BE HOT DIPPED GALVANIZED STEEL. WASTE AND VENT PIPING BELOW GRADE OR EMBEDDED M CONCRETE SHALL BE CAST IRON. THE CONTRACTOR MAY AT HIS DISCRETION USE P.V.C. - D.W.C. SCHEDULE 40 PIPE IF APPROVED BY LOCAL AUTHORITY /OWNER GASKETED AND /OR "NO HUB" JOINTS: THE CONTRACTOR MAY, AT HIS DISCRETION, USE ABOVE GRADE POSITIVE DOUBLE SEAL ELASTOMERIC COMPRESSION TYPE GASKETS WITH BELL AND SPIGOT PIPE ENDS, "NO -HUB" PIPE ENDS WITH RESILIENT SLEEVES AND METAL CLAMPS EQUAL TO TYLER'S "TY- SEAL" AND TYLER'S "NO -HUB" MAY BE USED ABOVE FLOOR GASKETS AND RESILIENT SLEEVES SHALL BE VIF;b3IN RUBBER OR NEOPRENE. OUTSIDE METAL CLAMPS ON "NO -HUB" JOINTS SHALL BE STAINLESS STEEL. GRADE WASTE AND VENT PIPING 1/4 INCH PER FOOT (MIN) FOR PIPIE SIZES 2 1/2" OR LESS. FOR PIPE SIZES 3" TO 6" GRADE 1/8 INCH PER FOOT (MIN), 8" OR LARGER PIPE, GRADE MIN I 116" PER FOOT, REFER TO TABLE 104.1 OF THE NC PLUMBING FOR MINIMUM SLOPE REQUIRED. SUBMITTAL: THE CONTRACTOR SHALL WITHIN (15) DAYS OF RECEIPT OF PROPERLY SIGNED CONTRACT SUBMIT TO THE ARCHITECT/ENGINEER FOR APPROVAL (5) COPIES OF A LIST OF SUPPLIES AND MANUFACTURER'S MATERIAL AND EQUIPMENT TO BE USED ON THIS PROJECT. SUBSTITUTION OF MATERIALS AND /OR EQUIPMENT FOR THAT SPECIFIED WILL NOT BE ACCEPTED WITHOUT PRIOR WRITTEN APPROVAL BY THE ARCHITECT/ENGINEER PRIOR TO RECEIPT OF BIDS. GENERAL: THE ENTIRE PLUMBING SYSTEM SHALL BE IN ACCORDANCE WITH THE N.C. STATE PLUMBING CODE. SUBMIT THREE (B) COPIES OF PLUMBING INSPECTION CERTIFICATES TO OWNER PLUMBING CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS REQUIRED BY GOVERNING AUTHORITIES FOR WORK DONE UNDER THIS CONTRACT. PROVIDE AND INSTALL ALL SUPPORTS, BRACKETS, MATERIALS AND LABOR AS REQUIRED FOR A COMPLETE AND ACCEPTABLE PLUMBING SYSTEM. PLUMBING CONTRACTOR SHALL CLEAN ALL PLUMBING FIXTURES AFTER ALL CONSTRUCTION IS COMPLETE. GUARANTEE: THE PLUMBING CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF FINAL ACCEPTANCE BY OWNER STATING THE DAY THE GUARANTEE BEGINS AND ENDS. CLEANOUTS: �tSfe CLEANOUTS SHALL BE AS FOLLOWS: FLOOR CLEANOUTS - IN FINISHED AREAS - JOSAM 0 5500 -1 -SQ WITH SQARE NICKEL BRONZE TOP - IN TILE FLOORS -JOSAM "5500 -I -SQ - IN CARPETED FLOORS -JOSAM "5"5500 -1 -SQ WALL CLEANOUTS - JOSAM 0 58 - 110 WITH STAINLESS STEEL COVERPLATE CLEANOUTS IN EXPOSED PIPING - J05AM 0 58SOO EXTERIOR CLEANOUTS - JOAM • 56050 W/ROUND NICKEL BRONZE TOP CLEANOUTS IN WATERPROOF FLOOR SHALL HAVE FLASHING FLANGE AND CLAMPING DEVICE. CLEANOUTS IN CARPETED AREAS SHALL BE PROVIDED WITH CARPET MARKERS. TIE NEW SEWER LINE INTO EXISTING MANHOLE PC TO VERIFY INVERT. $a OR 24" RD. X 8" THICK CONCRETE PAD 4 CHAMFERED EDGE$ AND BROOM FINISH 514 WITH FINISH GRADE OR BELOW PAVEMENT PLUMBING CONTRACTOR SECTIONAL CLEANOUT WITH INSIDE CAULK BODY, HEAVY DUTY SCORIATED COVER FINISH PAVING BY GENERAL CONTRACTOR = 1j11 g111P —f i1gil UE-11 E TO LONG SWEEP OR LONG TURN COMBINATION. NOV: OMIT CONCRETE PAD IF CA. IS SET IN OONC. SURFACE PROVIDED BY GENERAL CONTRACTOR OUT AT FINI GRADE SCALE: NONE FLOOR PLAN PLUMBING SG4LE: ' %" = 1' -0" 050806DR5I15600 1 BRITTAIN ENGINEERING, INC. CONSULTING BOX 939 HICKORY. NO 28603 ELECTR ENGINEERS 39LW" FAX f8281 328 TEL post office box 12 39 226 second street nw hickory, north carolina 28601 phone (828) 32 fax (828) 322 -1802 email cbsa @cbsa- architects.com J O 0 CO 2 Cn W W F- Ix O LL w J 0 U ad IY_ W IN w cr LL Z z O U a m Q a U DATE U) J 0 0 2 U Z J O a U z d Q Q U PROJECT NO: 2007.017 BY: BY: CBSA ARCHITECTS, INC. 2006 SHEET TITLE Floor Plan - Plumbing SHEET P1 OF PLUMBING f NCB LMGMNC� SYMBOL DESCRIPTION SANITARY WASTE -- - -- SANITARY VENT - -- DOMESTIC COLD WATER — - -- DOMESTIC HOT WATER — - - -- DOMESTIC HOT WATER RBCIRC. — t>�— SHUT -OFF VALVE -- COMBINATION F$.OW CONTROL/ BALL VALVE —o-I CUT -OFF VALVE IN RISER —o RISER UP AND RISER DOWN --O —i CLEAN= (CO) a HOSE BIBS (HIS) OR WALL HYDRANT (UP) VTR VENT THRIJ ROOF $A SHOCK ABSORBER "WATER HAMMER" M ELECTRICAL CONTRACTOR MjC MECHANICAL CONTRACTOR FLOOR PLAN PLUMBING SG4LE: ' %" = 1' -0" 050806DR5I15600 1 BRITTAIN ENGINEERING, INC. CONSULTING BOX 939 HICKORY. NO 28603 ELECTR ENGINEERS 39LW" FAX f8281 328 TEL post office box 12 39 226 second street nw hickory, north carolina 28601 phone (828) 32 fax (828) 322 -1802 email cbsa @cbsa- architects.com J O 0 CO 2 Cn W W F- Ix O LL w J 0 U ad IY_ W IN w cr LL Z z O U a m Q a U DATE U) J 0 0 2 U Z J O a U z d Q Q U PROJECT NO: 2007.017 BY: BY: CBSA ARCHITECTS, INC. 2006 SHEET TITLE Floor Plan - Plumbing SHEET P1 OF