Loading...
HomeMy WebLinkAboutCBPR-3-11-9996 NC Dept. of Public Instruction Plan Review Comments.tif APR -08 -2011 17:20 CATAWBA COUNTY 1 828 465 8962 P.001 p I l APR 1 12011 BY: Date: 04/08/2011 07:03 NO. OF PAGE: 3 (include this page) To: 3 -41 C From: TEL FAX: (TEL) 919 - 807 -3554 (FAX) 919 - 807 ,3558 i Department: NC Department of Public Instruction Company: School Planning i Comment: 3 { ti y i APR -08 -2011 17:20 CATAWBA COUNTY 1 828 465 8962 P.002 / . PUBLIC SCHOOLS 'OF NORTH -CAROLINA DEPARTMENT OF PUBLIC INSTRUCTION :: SCHOOL PLANNING Phone: (919) 807 -3554 6319 Mail Service Center Fig: (919) 807.3558 Raleigh, NC 27899.6319 www.schoddearinghouse.org I plan review to: Thomas L. Balks, AIA, Little Diversified Arch Consulting - Charlotte i fax: 704 -561 -8700 Dr. Lillie Cox, Superintendent i courier, 09 -74 -01 Hickory from: Ken Phelps, School Planning Consultant, School Planning phone: 9198073561 email: kphelpsc@dpi.state.nc.us subject; Hickory City Schools Hickory Career & Art Magnet School - renovations — DSP No: 181 -1378 Project it 5441 date: ApdI O7, 2011 i Construction documents for the Hickory Career & Art Magnet School - renovations project were received on March 24, 2011. The following architectural review comments are submitted to the designer and the Hickory City Schools for consideration in accordance with G.S. 11 5C-521. Comments by other disciplines, if any, will be forwarded under separate cover. A Certificate of Review will be issued after plan review has been completed. The drawings were dated 3/14/2011 and marked "Construction Documents." The project manual indicates bids are scheduled for April 21, 2011. Response to these review comments is required to complete the review process. 1, G 001 List of Designers shows Civil as NA, but there are civil drawings. 2. CS 100 Delete this sheet (I think it is leftover from an earlier phase). It is incomplete, and the Vicinity Map shows incorrect street names, 3. C 100 Symbols in Erosion Control Legend cannot be seen. 4. C 200 Is fencing required? If so, where -- at LOC (sheet C100)? Is there a designated area for Contractors material storage area, trailers, jobsite office? 5, drafting Generally, existing construction to be removed is shown with dashed lines, and existing / to remain is shown with a light / solid line. Showning existing / to remain with a dotted line is confusing. 6. A001 Detail 2, Coordinate "Block Width" with dimension shown. Coordinate wall types with designations shown on plans. [In details, Types MIA, M1B, MIC, M2A, M2B etc., but plans show M1, M2, etc,] * 7. A002 Door Elevations: show dimensions and type of glass. Door Schedule, show fire rating if required 8. A101 Notes: on the drawings, it is difficult to tell if notes are General Plan Notes, Demolition Key Notes, General Finish Notes, or General Ceiling Notes. • Indicates a potential Building code issue Delivery Address: 7066 NC Education Building - 301 N, Wilmington St., Raleigh NC 27601 Page 7 of 2 i F i APR -08 -2011 17:20 CATAWBA COUNTY 1 828 465 8962 P.003 ` cg pPL- -3- It- qqq& ' Plan Review: Hickory Magnet, April 7, 2011 9, A101 Plan Area A: 9 you leave the glass windows in place, they WILL get broken. Why have an enclosed space between the existing exteriorwall and the new wall? Close these window openings now. OR... There is no visual security into the enclosed access walkway to the new HC lift Consider removing existing windows, creating a cased opening; terminate new wall at appropriate height, install "floor' at window sill, so that observation into this area is possible from the existing corridor. (New interior wall is no longer bearing, so structure would have to be changed.] TO, A101 Re: new knee wall at new HC lift in existing stair -- it would W helpful to have an elevation or section through this wall. What is the exising base on the other end of the stairs? New base is called as RB1. 11. A102 Show slab depression for cooler. Show exhaust hood and diswasher exhaust in reflected ceiling plan: Provide Roof Plan showing penetrations, and details. Coordinate with FS sheets, See comment 12. Confirm: is there enough room between ceiling and roof structure to accommodate ductwork in area of exhaust hood? See mechanical plan 3/M101. 12. Food Please clarify: FS drawings are noted "for information only," and FS is not referenced in project Service manual, summary of work, etc. Is FS equipment to be furnished by Owner, installed after Final Completion? If installed concurrently with this Work, you should inform the contractor of that 13, A102 Cosmetology area: will manicure services be included? If so, be aware that requirements for exhaust and supply air are critical. 14. A102 -3 General note on A103 makes contractor responsible to comply with ANSI A117,01. It would be better to show & schedule grab bars. (See sheet A106) * 15. A106 Toilet Accessories: an additional vertical grab bar is now required. 16. A104 Why is there a "new safety shower' in the Criminal Justice room? It does not show up on the plumbing drawings. Please coordinate. * 17. A104 What grade levels will use the Science room? What subjects will be taught there? Will any chemicals be stored / used? (This is critical -- please respond a.s.a.p.) Is casework in the Science room the same as in the Criminal Justice room? If so, please note. 18. A105 Add dimensions to locate new walls. Why use 8" emu as screen wall in toilets, and as plumbing chase wall? Masonry walls would be a better choice than gyp board in the Shop / Production Room. 19. A106 Women's Toilet [031]: do not construct a chase made of toilet partition; increase width of toilet stalls if necessary, Detail 2: where is this "cut?" 20, A301 Roof -edge details: showing a single hash line through the blocking indicates that it is not continuous. Two lines indicates continuous blocking, You will want at least the top piece, the bottom piece, and the outer (vertical) piece to be continuous. 21. A301 Sections 1 & 2: show, note, or specify brackets to secure downspouts. Thank you for providing these documents for review. We look forward to receiving your written response. pc: City of Hickory Bldg. Inspections Mr. Frank Southers, Maintenance Director s i t f r Indicates a potential Building Code issue Delivery Address: 7066 NC Education Building - 301 N. Wilmington St., Raleigh NC 27601 Page 2 of 2 i TOTAL P.003