HomeMy WebLinkAboutENG RPT RETAINING WALL.TIFN110�Lbf►�C��t�DM � . 3 , T24 . k +� ��v t � � P . ZI A V D m4 c .�i►�'r�t P. 02 . �O MRR -30 -2009 09:16 PM Kenneth E. Carr ENGINEER -- CIVIL North Carolina LICenaa 0 031238 704 -534 -8460 t fax 7D7.527.9293 i i n f o®k a ca wvI rteW3. co m March 30, 2009 M10-Atlantic Custom Builders, Inc. P.O. Box 3792 Mooresville, NC 28117 RE' Concrete Retaining Wall Design 7271 Long Island Drive Catawba County, NC Permlt # BLD2007 -8399 To Whom It May Concern r.er Per your request, Kenneth E. Carr Is providing an engineered concrete retaining wall design for Vie referenced project. The proposed retaining wall (see attached detail) has a stem height of 11 -feet or 12 - feet (maximum) per the detail. The footing is to be constructed per the attached detail depending on the stem height desired and contains #5 dowels at the on- center spacing shown for the stem height selected. The 10 -inch thick concrete stem Contains vertical and horizontal #4 bars spaced as shown, depending on the stem height. Concrete used shall attain minimum design strength Of 3000 -psi compressive strength 028 days Sased on the above design, the cast in place concrete retaining wait shall provide adequate support for the intended use in accordance with the North Carolina State Residential Builcirg Code. Sincerely, ��»> Kenneth E. Carr R.E.( U31236 #31238 ' fax to Irvnatvne Found at � 7D4-662 -8778 Tejephom (707) 834 -94M - FaMrrWe (707) 527.9914