HomeMy WebLinkAboutBLD2007-01900 3-11-08 REPORT.TIF[z REScheck Software Version 4.1.3
Compliance Certificate
Project Title: JVM Homes - Dine Residence
Report Date: 03/11M
Data filename: C:\ Users\ OwnerlDreumems \Dacvmenis\CFSV2escheckyvm homes dine.rck
Energy Coda:
20031ECC
20.0 0.0 118
Location:
Sherrills
Ford, North Carolina
Construction Type:
Si Is Family
Glazing Am Percentage:
10X
Heating Degree Days:
3870
Construction Site: Owner /Agent Designer /Contractor.
31%Storamill Path
Slwrrils Ford, NC
Compliance: 20.2% Rather Than Coda Madmum UA: 658 Your UA: 526
Ceiling 1: Cathedral Ceiling (iro aft)
2354
20.0 0.0 118
Wall 1: Wood Forme, 16' o.c
2255
13.0 0.0 158
Window l: Wood From :DOUble Pane with LOw -E
168
0.290 49
Door 1: Solid
21
0.600 11
Door 2: Solid
21
0.500 11
Door 3: Said
21
0.500 11
Doors: Glass
56
0.300 17
Door S: Glass
21
0.300 6
Door6: Glass
21
0.300 6
Wall 2: Wo Forme, 16' o.c.
424
130 0.0 29
Window 2: Wood From :Double Pare with Low-E
74
0.290 21
gables: Wood Frame, 16' oo
748
13.0 0.0 61
Floor l: All -Wood Joist/rruss:(one Uraoditiorsd Space
600
190 00 28
(Aeon iano3 Statement no propoead trading design deap ood here is minters with Me buiairg glare, Weakin6ons, and other
ralmlations submiited with the Permit application. The Proposed building has been designed M meal tlw 2003 IECC m0uimrtsMS in
REScheck Version 4.1.3 and to comply ydh the mandatory requirement
listed In Me
RESoheclr Impaction Cherklht.
i- CnexilnMm' Sdf4.NLMJ
�rr
DS
Name - Title
N o. Title
mare
e
Date
Project Notes:
Installation of Me Int mre Insulation System M an unneeded antic assembly
Carolina Foam Solutions, Inc (Icyrere au idetsed dealer)
loynene Was installed Per manufacturer speci6ratbrs
Walls - Nominal 3.5 (R -13)
A6ic (unvented) - Nominal 5.5' (R -20)
Gamge Geilirg - Nominal 5' (R -19)
Project Title: JVM Homes Dine Residence Report date: 03/11/08
Data filename: C: \Users\GwneM menislDOCUmente \CFS\RB eckjvm homes dine.rak Page 1 of 1
CFS
Insslatmn For Living
March 1, 2008
County Code Enforcement
Subject: Icynene Installation
Dear Official,
We have installed The Icynene Insulation System in accordance with manufacturer
specifications. Icynene has or will be installed at a nominal thickness of 5.5 inches
(R -20 / 95% thermal heat now reduction) on an unvented attic assembly. We have
installed at a nominal thickness of 3.5 inches (R -13 / 92% thermal heat Flow
reduction) on main and upper level exterior walls and gables. We have installed a
nominal thickness of 5 inches (R -19 / 94% thermal heat now reduction) on porch
return areas.
Please let me know if you have any further questions
Best Regards,
Todd Nichols
Carolina Foam Solutions, License #2518
704.400.6488
Cc: JVM Homes- Dine Residence
3196 Stonemill Path
Sherrils Ford, NC 29673
C FS
Insulation fnr Living
March 11, 2008
County Code Enforcement
Subject: Fire /Draft Stopping
Dear Official,
We have installed Great Stuff fire stopping/ draft stopping foam on all required penetrations. Great
Stuff foam sealant has been evaluated and approved by ICC evaluating services as the only fire
stopping foam product on the market.
Please let me know if you have any further questions.
Best Regards,
Todd Nichols
Carolina Foam Solutions
704.400.6488
Cc: JVM Homes- Dine Residence
3196 Stonemill Path
Sherrils Ford, NC 29673
r l ��
tion for Living
March 11, 2008
County Code Enforcement
Subject: Ignition Barrier Installation
Dear Official,
We have installed The Icynene Insulation System in accordance with manufacturer specifications to
include the installation of the ignition barrier FF88 on vertical surfaces in the attic at a rate of 1
gallon per 100 sq ft.
Please let me know if you have any further questions.
Best Regards,
Todd Nichols
Carolina Foam Solutions
704.400.6488
Cc: JVM Homes- Dine Residence
3196 Stonemill Path