HomeMy WebLinkAboutBLD2007-01612 ENR LTR 9-11-07.TIF-� L_?,'2 609-N4 4;-
A. MILES CHAMPION,
1142 11th St. Cir. NW
Hickory, NC 28601
JR., P.E.
ber 11, 2007
Mark Mullen
334 South Aspen Street
Lincolnton, NC 28093
Dear Mark:
The moveable ramp as shown on construction drawings dated July 17, 2007
may be extended from 16 feet to 20 feet in length. The joists must be single 20-
foot section or two 10 -foot pie s with a 12' 2x8 splice. Add one (1) additional
section of 2x8 bridging. Plea call me if you have any questions.
Sincerely,
A. Miles Champion, Jr.,
SEAL `
17 592
Qft
k SOP
CHAMQ_,.�►