Loading...
HomeMy WebLinkAboutBLD2005-00880 GROUT PRISM RPT NOV-DEC 05.TIFf MACTEC Set ID: 200513965 2801 Yorkmont Rd. Suite 100 , Charlotte, NC 28208 GROUT PRISM TEST REPORT Client: CATAWBA COUNTY Project: CATAWBA COUNTY JAIL MIX ID: GROUT MIX DESC: FIELD INFORMATION DATE SAMPLED: 10/20/2005 BY: RON HARPER SLUMP, INCHES: TIME BATCHED: TIME SAMPLED: 9:00 AM AIR CONTENT %: BATCH PLANT: RMC UNIT WEIGHT, PCF TRUCK: 1328 DATE RECV'D: AIR TEMP, °F: TICKET: MIX TEMP, °F: rnMPRFSSInN TEST RESULTS FIELD TESTS (ACTUAL) (SPECIFIED) 7 LO: 0 HI: 0 N/I LID:0 HI:0 N/I LO:0 HI:0 80 LO: 0 HI: 0 76 LO: 0 HI: 0 CYL. NO. AREA (SQ.IN.) DATE TESTED TEST AGE (DAYS) MAX. LOAD (LBS.) COMP. STRENGTH (PSI) FRACTURE TYPE C1 3.14 10/27/2005 7 4790 1530 <<< 1 C2 3.14 11/17/2005 28 7660 2440 <<< 2 C3 3.14 11/17/2005 28 7540 2400 <<< 1 C4 28.3 R DATE: 11/17/05 JOB NO: 6234052987 SPECIFIED STRENGTH: 3000 PSI UNLESS OTHERWISE INDICATED, TESTS WERE PERFORMED IN GENERAL ACCORDANCE WITH THE FOLLOWING ASTM TEST METHODS C39, C738, C143, Ci73 or C231, C1064 SLUMP MEASURED TO ONE - QUARTER INCH AIR CONTENT MEASURED TO ONE - QUARTER PERCENT *DENOTES CURED INFIELD — DENOTES LOW COMPRESSIVE STRENGTH FRACTURE TYPE IS INDICATED BY NUMBER CORRESPONDING TO FRACTURE PATTERN SHOWN IN ASTM C39 AND SKETCHES BELOW: <1 in. I i U Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Type 7 REMARKS: POUR LOCATION: ALL SECURITY WALL IN SECTION (A) GROUND ELEV. ACTURAL KS 7 TO 12 LINE DISTRIBUTION: RESPECTFULLY SUBMITTED: CATAWBA COUNTY SCHOOLS, ERNEST WILLIAMS, JR. HICKORY CONSTRUCTION CO., AARON BEAM e LITTLE DIVERSIFIED ARCHITECTURAL CONSULTING, DAVID CONKLIN l � L - c_- . WILLIAM C. HOWLAND, JR., P.E. f MACTEC Set ID: 200514009 2801 Yorkmont Rd. Suite 100 , Charlotte, NC 28208 GROUT PRISM TEST REPORT Client: CATAWBA COUNTY Project: CATAWBA COUNTY JAIL MIX ID: GROUT MIX DESC DATE: 12/2/05 JOB NO: 6234052987 SPECIFIED STRENGTH: 3000 PSI FIELD TESTS FIELD INFORMATION (ACTUAL) DATE SAMPLED: 10/25/2005 BY: RON HARPER SLUMP, INCHES: TIME BATCHED: 9:25 AM TIME SAMPLED: 10:30 AM AIR CONTENT %: BATCH PLANT: RMC UNIT WEIGHT, PCF TRUCK: 1338 DATE RECV'D: 10/31/2005 AIR TEMP, °F: TICKET: 8009407 MIX TEMP, °F: 50500 COMPRESSION TEST RESULTS FIELD TESTS AREA (SQ.IN.) (ACTUAL) (SPECIFIED) 7 LO: 0 HI: 0 N/I LO:0 HI:0 N/I LO:0 HI:0 55 LO: 0 HI: 0 60 LO: 0 HI: 0 CYL. NO. AREA (SQ.IN.) DATE TESTED TEST AGE (DAYS) MAX. LOAD (LBS.) COMP. STRENGTH (PSI) FRACTURE TYPE C1 17.58 11/22/2005 28 43390 2470 <<< 1 C2 17.01 11/22/2005 28 50500 2970 <<< 1 C3 28.3 12/20/2005 56 UNLESS OTHERWISE INDICATED. TESTS WERE PERFORMED IN GENERAL ACCORDANCE WITH THE FOLLOWING ASTM TEST METHODS C39, C138, C143, C173 or C231. C1064 SLUMP MEASURED TO ONE - QUARTER INCH AIR CONTENT MEASURED TO ONE- QUARTER PERCENT ' DENOTES CURED IN FIELD — DENOTES LOW COMPRESSIVE STRENGTH FRACTURE TYPE IS INDICATED BY NUMBER CORRESPONDING TO FRACTURE PATTERN SHOWN IN ASTM C39 AND SKETCHES BELOW: _..I - <1 in. y Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Type 7 REMARKS: POUR LOCATION: SECURITY WALL SECTION E, SECTION C ALONG F LINE FROM 4.3 TO 5.8, 5.8 LINE FROM D TO F AT GROUND LEVEL DISTRIBUTION: CATAWBA COUNTY SCHOOLS, ERNEST WILLIAMS, JR. HICKORY CONSTRUCTION CO., AARON BEAM LITTLE DIVERSIFIED ARCHITECTURAL CONSULTING, JACK ARMFIELD RESPECTFULLY SUBMITTED: � (' )A WILLIAM C. HOWLAND, JR., P.E. 0 A MACTEC Set ID: 200514009 2801 Yorkmont Rd. Suite 100 , Charlotte, NC 28208 GROUT PRISM TEST REPORT Client: CATAWBA COUNTY Project: CATAWBA COUNTY JAIL MIX ID: GROUT MIX DESC: DATE: 12/20/05 JOB NO: 6234052987 SPECIFIED STRENGTH: 3000 PSI FIELD INFORMATION DATE SAMPLED: 10/25/2005 BY: RON HARPER SLUMP, INCHES: TIME BATCHED: 9:25 AM TIME SAMPLED: 10:30 AM AIR CONTENT %: BATCH PLANT: RMC UNIT WEIGHT, PCF TRUCK: 1338 DATE RECV'D: 10/31/2005 AIR TEMP, °F: TICKET: 8009407. MIX TEMP, °F: COMPRESSION TEST RESULTS FIELD TESTS (ACTUAL) (SPECIFIED) 7 LO: 0 HI: 0 N/I LO:0 HI:0 N/I LO:0 HI:0 55 LO: 0 HI: 0 60 LO: 0 HI: 0 CYL. NO. AREA (SQ.IN.) DATE TESTED TEST AGE (DAYS) MAX. LOAD (LBS.) COMP. STRENGTH (PSI) FRACTURE TYPE C1 17.58 11/22/2005 28 43390 2470 <<< 1 C2 17.01 11/22/2005 28 50500 2970 <<< 1 C3 15.99 12/20/2005 56 53960 3370 1 UNLESS OTHERWISE INDICATED, TESTS WERE PERFORMED IN GENERAL ACCORDANCE WITH THE FOLLOWING ASTM TEST METHODS C39, C138. C743, C173 or C231, C1064 SLUMP MEASURED TO ONE- QUARTER INCH AIR CONTENT MEASURED TO ONE - QUARTER PERCENT - DENOTES CURED INFIELD — DENOTES LOW COMPRESSIVE STRENGTH FRACTURE TYPE IS INDICATED BY NUMBER CORRESPONDING TO FRACTURE PATTERN SHOWN IN ASTM C39 AND SKETCHES BELOW: <1 In. Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Type 7 REMARKS: POUR LOCATION: SECURITY WALL SECTION E, SECTION C ALONG F LINE FROM 4.3 TO 5.8, 5.8 LINE FROM D TO F AT GROUND LEVEL DISTRIBUTION: CATAWBA COUNTY SCHOOLS, ERNEST WILLIAMS, JR. HICKORY CONSTRUCTION CO., AARON BEAM LITTLE DIVERSIFIED ARCHITECTURAL CONSULTING, JACK ARMFIELD RESPECTFULLY SUBMITTE : r WILLIAM C. HOWLAND, JR., P.E.