HomeMy WebLinkAboutBLD2005-00880 GROUT PRISM RPT JAN 06.TIFNk'\4w. OMACTEC Set ID: 200514421 2801 Yorkmont Rd. Suite 100 , Charlotte, NC 28208 GROUT PRISM TEST REPORT Client: CATAWBA COUNTY DATE: 1/6/06 Project: CATAWBA COUNTY JAIL JOB NO: 6234052987 MIX ID: GROUT SPECIFIED STRENGTH: 3000 PSI MIX DESC: CYL. NO. FIELD INFORMATION DATE TESTED FIELD TESTS MAX. LOAD (LBS.) COMP. STRENGTH (PSI) FRACTURE TYPE C1 (ACTUAL) (SPECIFIED) DATE SAMPLED: 12/30/2005 BY: RON HARPER SLUMP, INCHES: N/I LO: 0 HI: 0 TIME BATCHED: 10:29 AM TIME SAMPLED: 11:30 AM AIR CONTENT %: N/I LO: 0 HI: 0 BATCH PLANT: RMC UNIT WEIGHT, PCF: N/I LO: 0 HI: 0 TRUCK: 2230 DATE RECV'D: AIR TEMP, °F: 50 LO: 0 HI: 0 TICKET: 8010123 MIX TEMP, °F: 60 LO: 0 HI: 0 COMPRESSION TEST RESULTS CYL. NO. AREA (SQ.IN.) DATE TESTED TEST AGE (DAYS) MAX. LOAD (LBS.) COMP. STRENGTH (PSI) FRACTURE TYPE C1 16.8 1/6/2006 7 45440 2700 1 C2 28.3 1/27/2006 28 C3 R UNLESS OTHERWISE INDICATED, TESTS WERE PERFORMED IN GENERAL ACCORDANCE WITH THE FOLLOWING ASTM TEST METHODS C39, C138, C143, C173 a C231, C1064 SLUMP MEASURED TO ONE - QUARTER INCH AIR CONTENT MEASURED TO ONE - QUARTER PERCENT - DENOTES CURED IN FIELD — DENOTES LOW COMPRESSIVE STRENGTH FRACTURE TYPE IS INDICATED BY NUMBER CORRESPONDING TO FRACTURE PATTERN SHOWN IN ASTM C39 AND SKETCHES BELOW: <1 In. Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Type 7 REMARKS: POUR LOCATION: MASONRY WALL ON 5 LINE R TO 2 LIFT #3 AND 5.6 LINE L TO N LIFT #2 DISTRIBUTION: CATAWBA COUNTY SCHOOLS, ERNEST WILLIAMS, JR. HICKORY CONSTRUCTION CO., AARON BEAM LITTLE DIVERSIFIED ARCHITECTURAL CONSULTING, JACK ARMFIELD RESPECTFULLY SUBMITTED: WILLIAM C. HOWLAND, JR., P.E. rMACTEC Set ID: 200514442 2801 Yorkmont Rd. Suite 100 , Charlotte, NC 28208 GROUT TEST REPORT Client: CATAWBA COUNTY Project: CATAWBA COUNTY JAIL MIX ID: GROUT MIX DESC: DATE: 1/12/06 JOB NO: 6234052987 SPECIFIED STRENGTH: 3000 PSI FIELD TESTS (ACTUAL) FIELD INFORMATION DATE SAMPLED: 1/5/2006 BY: RON HARPER SLUMP, INCHES: TIME BATCHED: 7:46 AM TIME SAMPLED: 9:00 AM AIR CONTENT %: BATCH PLANT: RMC UNIT WEIGHT, PCF: TRUCK: 7009 DATE RECV'D: 1/9/2006 AIR TEMP, °F: TICKET: 8010157 MIX TEMP, °F: 28 COMPRESSION TEST RESULTS FIELD TESTS (ACTUAL) (SPECIFIED) 8 LO: 0 HI: 0 N/I LO:0 HI:0 N/I LO:0 HI:0 49 LO: 0 HI: 0 60 LO: 0 HI: 0 CYL. NO. AREA (SQ.IN.) DATE TESTED TEST AGE (DAYS) MAX. LOAD (LBS.) COMP. STRENGTH (PSI) FRACTURE TYPE C1 16.56 1/12/2006 7 37710 2280 1 C2 2/2/2006 28 C3 2/2/2006 28 C4 R UNLESS OTHERWISE INDICATED, TESTS WERE PERFORMED IN GENERAL ACCORDANCE WITH THE FOLLOWING ASTM TEST METHODS C39, C138, C143, C173 or C231, C1064 SLUMP MEASURED TO ONE - QUARTER INCH AIR CONTENT MEASURED TO ONE - QUARTER PERCENT *DENOTES CURED INFIELD <<< DENOTES LOW COMPRESSIVE STRENGTH FRACTURE TYPE IS INDICATED BY NUMBER CORRESPONDING TO FRACTURE PATTERN SHOWN IN ASTM C39 AND SKETCHES BELOW: in. Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Type 7 REMARKS: POUR LOCATION: SECURE E603 INCHES LIFT NO. 1 /LINE 5.3, L TO M.8 LIFT #2 /LINE 5, P.5 TO M LIFT # 1 /SALLY PORT WALL 9 LINE, L TO R LIFT # 2 DISTRIBUTION: CATAWBA COUNTY SCHOOLS, ERNEST WILLIAMS, JR. HICKORY CONSTRUCTION CO., AARON BEAM LITTLE DIVERSIFIED ARCHITECTURAL CONSULTING, JACK ARMFIELD RESP TFULLY SUBMITTED: WILLIAM C. HOWLAND, JR., P.E. . ti , A MACTEC Set ID: 200514469 2801 Yorkmont Rd. Suite 100 , Charlotte, NC 28208 GROUT PRISM TEST REPORT Client: CATAWBA COUNTY Project: CATAWBA COUNTY JAIL MIX ID: GROUT MIX DESC: FIELD INFORMATION DATE SAMPLED: 1/10/2006 BY: RON HARPER SLUMP, INCHES: TIME BATCHED: 10:30 AM TIME SAMPLED: 11:30 AM AIR CONTENT %: BATCH PLANT: RMC UNIT WEIGHT, PCF: TRUCK: DATE RECV'D: 1/16/2006 AIR TEMP, °F: TICKET: MIX TEMP, °F: COMPRESSION TEST RESULTS DATE: 1/18/06 JOB NO: 6234052987 SPECIFIED STRENGTH: 3000 PSI FIELD TESTS (ACTUAL) (SPECIFIED) 7 LO: 0 HI: 0 N/I LO:0 HI:0 N/I LO:0 HI:0 48 LO: 0 HI: 0 60 LO: 0 HI: 0 CYL. NO. AREA (SQ.IN.) DATE TESTED TEST AGE (DAYS) MAX. LOAD (LBS.) COMP. STRENGTH (PSI) FRACTURE TYPE C1 16.16 1/17/2006 7 34240 2120 1 C2 28.3 2/7/2006 28 C3 28.3 2/7/2006 28 C4 R UNLESS OTHERWISE INDICATED, TESTS WERE PERFORMED IN GENERAL ACCORDANCE WITH THE FOLLOWING ASTM TEST METHODS C39, C138, C143, C173 or C231. C1064 SLUMP MEASURED TO ONE - QUARTER INCH AIR CONTENT MEASURED TO ONE - QUARTER PERCENT ' DENOTES CURED IN FIELD — DENOTES LOW COMPRESSIVE STRENGTH FRACTURE TYPE IS INDICATED BY NUMBER CORRESPONDING TO FRACTURE PATTERN SHOWN IN ASTM C39 AND SKETCHES BELOW: i <1 in. Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Type 7 REMARKS: POUR LOCATION: MASONRY WALLS ON 9 LINE, L TO R LINE, LIFT #3/Q.5 LINE, 7 TO 9 LINE, LIFT #3/ 5.3 LINE, N TO L LIFT #2 DISTRIBUTION: RESPECTFULLY SUBMI17 CATAWBA COUNTY SCHOOLS, ERNEST WILLIAMS, JR. HICKORY CONSTRUCTION CO., AARON BEAM LITTLE DIVERSIFIED ARCHITECTURAL CONSULTING, JACK Q ,/ ARMFIELD A WILLIAM C. HOWLAND, JR., P.E. a A MACTEC Set ID: 200514488 2801 Yorkmont Rd. Suite 100 , Charlotte, NC 28208 GROUT PRISM TEST REPORT Client: CATAWBA COUNTY Project: CATAWBA COUNTY JAIL MIX ID: GROUT MIX DESC DATE: 1/24/06 JOB NO: 6234052987 SPECIFIED STRENGTH: 3000 PSI FIELD TESTS (ACTUAL) FIELD INFORMATION DATE SAMPLED: 1/17/2006 BY: RON HARPER SLUMP, INCHES: TIME BATCHED: 12:45 PM TIME SAMPLED: 1:35 PM AIR CONTENT %: BATCH PLANT: RMC UNIT WEIGHT, PCF: TRUCK: 1346 DATE RECV'D: AIR TEMP, °F: TICKET: 8010298 MIX TEMP, °F: 28 COMPRESSION TEST RESULTS FIELD TESTS (ACTUAL) (SPECIFIED) 7 LO: 0 HI: 0 N/1 LO:O HI:0 N/I LO:0 HI:0 60 LO: 0 HI: 0 65 LO: 0 HI: 0 CYL. NO. AREA (SQ.IN.) DATE TESTED TEST AGE (DAYS) MAX. LOAD (LBS.) COMP. STRENGTH (PSI) FRACTURE TYPE C1 16.8 1/24/2006 7 39290 2340 1 C2 28.3 2114/2006 28 C3 28.3 2/14/2006 28 C4 R UNLESS OTHERWISE INDICATED, TESTS WERE PERFORMED IN GENERAL ACCORDANCE WITH THE FOLLOWING ASTM TEST METHODS C39, C138, C143, C173 or C231, C1064 SLUMP MEASURED TO ONE - QUARTER INCH AIR CONTENT MEASURED TO ONE - QUARTER PERCENT 'DENOTES CURED INFIELD — DENOTES LOW COMPRESSIVE STRENGTH FRACTURE TYPE IS INDICATED BY NUMBER CORRESPONDING TO FRACTURE PATTERN SHOWN IN ASTM C39 AND SKETCHES BELOW: - _.- 11_....<1 in. ) Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Type 7 REMARKS: POUR LOCATION: BLOCK WALL ON MAGISTRATE DURESS E 305, LIFT #2 AND 6 LINE R.8 TO S, 6 LINE Q.5 TO R, LIFT #1 DISTRIBUTION: CATAWBA COUNTY SCHOOLS, ERNEST WILLIAMS, JR. HICKORY CONSTRUCTION CO., AARON BEAM LITTLE DIVERSIFIED ARCHITECTURAL CONSULTING, JACK ARMFIELD RESPECTFULLY SUBMITTED: WILLIAM C. HOWLAND, JR., P.E.