DAILY REPORT
Client- Mr. Jeremy Norman
Building Systems, General Contractors
P.O. Box 3409
Hickory, NC 28603-3409
Project: Hart Entertainment
Hickory, NC
F&R Project Number E 77-141 T
Date: 02/24/04
Technician: Wilson H, Goff -Chris Wright
— e 009,5"
of
The F&R representatives returned to the site as scheduled to continue the subgrade evaluation of
the pier footings.
The F&R technicians performed nine Dynamic Cone Penetrometer (DCP) tests and the results
are to be supplied to M, Sloan, F&R P,E., for his evaluation and recommendations.
Mr. Yount requested that F&R return to the site tornorrow to perform the SUbgrade evaluation of
the 4 interior pier locations after they are excavated.
Respectfully Submitted,
FROEHLING & ROBERTSON, INC.
4wo , 5 6,
Michael W. Sloan, P.E.
Branch Manager
HEADQUARTERS: 1015 Du BARTON ROAD - BOX 27524 - RICHMOND, VA 23261-7524
TELEPHONE (904) 264-2701 - FAX (904) 264-1202 - www.FandR.com
BRANCHES: ASHEVILLE, NC - BALTIMORE, MD - CHARLOTTE, NC - CHESAPEAKE, VA
S t N C F
a
FOUNDATION BEARING GRADE REPORT
Project: I fart F"ritertainment Permit No: N/A
Client: fluilding Systems, Gen. contr. Date (on -site): 2124/2004 (Pg. 1)
F&R Representative: W. Goff/C. Wright Project No.: E77-141T
DYNAMIC CONEL I'll"'NETRATION TESTS (ASTM S )ecial Technical Publication No. 399)
_71
. . . . .....
pq "'n 7p
PROM4 -
01
2 9 6 Flll-Rad Brown Sandy t w/Mica
-11
12 16 14 Fill -Red Brown Sandy Silt w/Mica
Rear Wall -Flier No, 2-SL -2'
-
9 9 9 Fill -Red Brown Sandy Silt w/Mica
-Y
9 10 9 Fill -Red Brown Sandy Silt w/Mica
13 17 15 Fill -Red Brown Sandy Silt w/Mica
01
2 7 5 Fill -Red Brown Sandy Silt w/Mica
18 18 18 Fill -Red Brown Sandy Silt w/Mica
2 Rear Wall -Pier No. 3-SC, -2'
11 12 12 Fill -Red Brown Sandy Silt w/Mica
-Y
204 201 Fill -Red Brown Sandy Silt w/Mica
-4
16 16 16 Fill -Red Brown Sandy Silt w/Mica
-5'
14 13 14 Fill -Red Brown Sandy Silt w/Mica
-6'
16 19 17 Fill -Red Brown Sandy Silt w/Mica
-T
12 16 14 Fill -Red Brown Sandy Silt w/Mica
-81
17 18 17 Fill -Red Brown Sandy Silt w/Mica
-91
20f 20 I- Residual -Red Brown Sandy Silt w/Mica
01
2 6 4 Fill -Red Brown Sandy Silt w/Mica
_V
12 15 13 Fill -Red Brown Sandy Silt w/Mica
3 Rear Wall -flier No. 4-St, -2'
8 10 9 Fill -Red Brown Sandy Silt w/Mica
-Y
8 12 10 Fill -Red Brown Sandy Silt w/Mica (Pc Root
@T)
-4
14 15 14 Fill -Red Brown Sandy Silt w/Mica
01
9 11 10 Fill -Red Brown Sandy Silt w/Mica
8 10 9 Fill -Red Brown Sandy Silt w/Mica
4 Rear Wall -Pier No, 5-St, .,2'
8 10 9 Fill -Red Brown Sandy Silt w/Mica
-Y
10 10 10 Fill -Red Brown Sandy Silt w/Mica
4
14 16 15 Fill -Red Brown Sandy Silt w/iWca
Note: N, is file average of the Second an(f Mir() 1)('p
rea(lirlgs
Any opinions or recommendations should be based on tire field observations made the
should be free elf soft, loose, wet, organic, caved -in soils
and tests performed. All bearing grades
or otherwise deleterious materials and conditions immediately
the placement ofconcrete, Exterior foundations should
prior to
be embedded at least 12-inches below the final
Exterior ivadeq dirmlel hp i— u__,
exterior grades.
11 -
SINCE
FOUNDATION BEARING GRADE RE11010"'
Project: I lart l"Atertainryient Pet-mit No: N/A
Client: Building Systeryis, Gen, Contr. Date (on -site): 2/2412004 (Pg. 2)
F&R I[Zepmseintative: W. G07C. Wright Pt-oject No.: E77-1411-
DY1' AMIC CONE, P EN E" FRATI ON TESTS (AST ication No. 399)
V Aill IUlls
ti
01 7 9 8 Fill -Red Brown Sandy Silt w/Mica
10 12 11 Fill -Red Brown Sandy Silt w/Mica
Right Side Wall (East} flier
5 2' 20 f 201 Fill -Red Brown Sandy Silt w/Mica
No. if-SL
-3' 12 10 1 1 Fill -Red Brown Sandy Silt w/Mica
4 15 15 15 Fill -Red Brown Sandy Silt w/Mica
01 6 9 8 Fill -Red Brown Sandy Silt w/Mica
-11 14 16 15 Fill -Red Brown Sandy Silt w/Mica
Right Rear Coiner
6 (Northeast) SL-St, -T 15 17 16 Fill -Red Brown Sandy Silt w/Mica
-Y 6 10 8 Fill -Red Brown Sandy Silt w/Mica
-4 11 10 Fill -Red Brown Sandy Silt w/Mica
-5' 15 16 15 Fill Pied Brown Sandy Silt w/Mica
-6' 10 16 13 Fill -Red Brown Sandy Silt w/Mica
-T 201 201- Fill -Red Brown Sandy Silt w/mica
-81 20+- 201 Fill -Fed Brown Sandy Silt w/Mica
-91 20-i20 F Residual -Red Brown Sandy Silt w/mrca
01 6 8 7 Fill -Red Brown Sandy Silt w/Mica
-11 7 13 10 Fill -Red Brown Sandy Silt w/Mica
Right Side Wall (East) flier
7 No. G-SL 2' L 10 11 In Fill -Red Brown Sandy Silt w/Mica
10 Fill -Red Brown Sandy Silt w/Mica
-T 13 16 15 Fill -Red Brown Sandy Silt w/Mica mm
83A
-51 17 204- 20( Fill -Red Brown Sandy Silt w/Mica
-6' 18 201- 20-1 Residual -Red Brown Sandy Silt w/Mica
Depth Below Footing Bearing Orade
Note: N, is the average of the second arof third DCP readings
Any opinions or recommendations should be based on the field observations made and the tests performed. All bearing grades
should be free of'soft, loose, wet, organic, caved -in soils or otherwise deleterious materials and conditions immediately prior to
the placement of concrete. Exterior foundations should be embedded at least 12-inches below the final exterior grades.
Exterior grades should be sloped to direct surface runoff away Crom structure,
$ I N C F
FOUNDATIONBEARING GRADE REPORT
Project: I fart F.trtertainment Permit No: N/A
Client: Building ysterns, (ien. Con1r, Date (on -site): 2/24/2004 (Pg. 3)
F&II Representative: W. Goff/C. Wright Project No.: E77-141 T
DYNAMICCONE 11',N11"FRATION TESTS (AS` N/l Special Technical l"ublication No. 399)
a, 6
9
7 Fill -Red Brown Sandy Silt w/Mica
-11 7
8
7 Fill -Red Brown Sandy Silt w/Mica
Right Side Wall (East) Pier 4
4
1 Fill -Red Brown Sandy Silt w/Mica (Sm.Grass
-T
No, F-SL
Roots 525)
_31 6
12
9 Fill -Red Brown Sandy Silt _w/Mica ( rn.Wood
-T 14
20f
20 1 Residual -Red Brown Sandy Silt w/Mica
0' 4
9
6 Fill -Red Brown Sandy Silt w/Mica
-11 8
10
9 Fill -Red Brown Sandy Silt w/Mica
Right We Wall (East) Pier
9
No. E-SL 2' 9
15
12 Fill -Red Brown Sandy Silt w/Mica
31 12
201
204 Residual -Red Brown Sandy Silt w/Mica
Depth Below Footing Hearing Grade
Note: N, is the average of the second anti third jai P readings
Any opinions or recommendations should be based on the field observations
invade and the tests performed, All bearing grades
should be free of soft, loose, wet, organic, caved -in soils or otherwise deleterious
materials and conditions itunrediately prior to
tire placement of concrete, Exterior foundations should be embedded at least
12-inches below the final exterior grades,