HomeMy WebLinkAboutB4-85 ENG RPT SUBGRADE EVAL.PDFSINCE
FROEHLING & ROBERTSON, INC.
GEOTECHNICAL # ENVIRONMENTAL * MATERIALS
ENGINEERS * LABORATORIES
"OVER ONE HUNDRED YEARS OF SERVICE"
i910 TATE BOULEVARD, SEISUITE 101/HICKORY, NC 2860"
TELEPHONE: 828-324-4081/FAX: 828-324-6770
EMAIL ADRESS: WWW.FANDR.COM
FCLUXIF114211M
Client: Mr, Jeremy Norman
Building Systems, General Contractors
P.C. Box 3409
Hickory, NC 28603-3409
Project: Hart Entertainment
Hickory, NC
F&R Project plurnber E77-141T
Date: 02/23/04
? - C�,
"�4 �JA
Technician: Wilson fi, Goff --Robert George -Michael W. Sloan, P.E.
The F&R representatives traveled to the site at the request of the client to perform a subgrade
evaluation at the perimeter pier footing locations, The 12-inch wide continuous wall footing had
been excavated around the perimeter, and the perimeter and interior pier foundations had been
layed out, Mr. Mike Yount, Building Systerns, requested that the evaluation be conducted prior to
excavating the piers to determine if any over -excavation would be required. Fie also stated that
2,000 pounds per square foot bearing capacity was required.
The site had been preViOLISly graded by others and contained about 2 to 9 feet of new fill.
Reportedly, the fill was tested for in -place density and met at least 95% compaction while being
placed. Hand probing the surface bearing soils indicated some areas to be soft.
The F&R representatives performed eight Dynamic Cone Penetrometer (DCP) tests throughout
the day by hand angering through the existing fill into the residual soils below, Mr. Yount was
informed that F&R would return to the site on Tuesday, February 24, 2004 to complete the
testing.
Respectfully Submitted,
FROEHLING & ROBERTSON, INC.
A
i I I r.') . <---
Michael W, Sloan, P.E.
Branch Manager
HEADOUARTER& 3015 DUMBARTON nOAD - BOX 27524 - RICHMOND, VA 23261-7524
TELEPHONE (804) 2644701 - FAX (804) 264-1202 - www.FandR.com
BRANCHES: ASHEVILLE, NC - BAL11MORE, MD - CHARLOTTE, NG - CHESAPEAKE, VA
Si NC E
9�69
FOUNDATION BEARING GRADE REPORT
Project: I fart Entertainment Permit No: N/A
Client: midding Systems, (Sen, Contr. Date (on -site): 2/23/2004 (Pg. 1)
F&R Representative: . Goff/R. George/M. Moan Project o.: E77-141T
q DYNAMIC COW,.' 1'1::;Nl. 'l'RA'l"l.ON TEST(ASTM. S ecial Tec mica.[ Pulllicatiotl No. 399)
y�y
0" 2 9 6 Fill -Red Brown Sandy Silt w/Mica
-11 5 7 6 Fill -Red Brown sandy Silt w/Mica
Northwest Corner (Drawing �
1 _2F 6 1 t 2 Fill -Red Brown Sandy Silt w/l`�1ica
Marked Sl,-S1.1}
-Y 10 15 13 Fill -Red Brown Sandy Silt w/Mica
4 9 15 12 Fill -Red Brown Sandy Silt w/Mica
5' 9 11 10 Fill -Red Brown Sandy silt w/Mica
' 8 10 9 Fill -Red Brown sandy silt w/Mica (65Small
Rock)
-T 16 19 18 Fill -Red Brown sandy silt w/Mica
-' k 13 11 Fill -Red Brown sandy Silt w/Mica
-9' 9 18 14 Residual -Red -Brown Clay Sandy Silt
01 3 8 6 Fill -Red Brown Sandy Silt w/Mica
-1' 12 14 13 Fill -Red Brown Sandy Silt w/Mica
West Wall Pier 13
2 -2' 13 17 15 Fill -Red Brown sandy Silt w/Mica
(Drawing Marked 13-SL)
-3' 13 16 15 Fill -Red Brown Sandy silt w/Mica
4 12 204- 201 Fill -Red Brown Sandy Silt w/Mica
-5' 16 12 14 Fill -Red Brown Sandy Silt w/Mica
_6 18 19 19 Fill -Red Brown Sandy Silt w/Mica
-7' 201 20 i Fill -Red Brown sandy Silt w/Mica
- ' 20+- 201 Residual -Red Brown sandy Silt w/Mica
-9' 201- 201 Residual -Red Brown Sandy Silt w/Mica
* 13ep1h Below Footing Bearing Gracie
Note: N, is the average of tie second and third [H.T re dings
Any opinions or recommendations should be based on the field observations made and the tests performed, All bearing gravies
should be free of soft, loose, wet, organic, caved -in soils or otherwise deleterious materials and conditions immediately prior to
the placement ofconcrete. Exterior Foundations should be embedded at least 12-inches below the final exterior grades.
S I N C E
t a3flA
FOUNDATION 13EARING GIUDE REPORT
Project: I fart Ir,ntertainment Permit No: N/A
Client: Building Systems, Gen. Contr. Date on -site): 2/23/2004 (Pg. 2)
F&R Representative: W, Gol 7R. George/M. Sloan Project No.: E77-141T
DYNAMIC:" GOOF' 11L," iE'FRATION TI;STS (ASTM S _ec,ial Technical Publication No. 399)
a' 2 10 fa Fill -Red Brown Sandy Silt w/Mica
-1' 20+ 20 t Fill -Red Brown Sandy Silt wlfvtica
West Wall Pier C
3 -2' 13 13 13 Fill -Red Brown Sandy Silt w/Mic;a
(Drawing Marked C-SL)
-3' 13 17 15 Fill -Red Brown Sandy Silt w/Mica
4 18 204 201 Fill -Red Brown Sandy Silt w/Mica
-5' 17 15 16 Fill -Red Brown Sandy Silt w/Mica
-6' 18 20 t 201 Fill -Red Brown Sandy Silt w/Mica
-T 201 204 Residual -Red Brown Sandy Silt w/Mica
0' 3 9 6 Fill -Red Brown Sandy Silt w/Mica
-1' 9 12 11 Fill -Red Brown Sandy Silt w/Mica
4 West Mall Pier 11 -2' 10 12 11 Fill -lied Brown Sandy Silt w/Mica
(Drawing; Marked D-SL)
-3' 12 11 11 Fill -Red Brown Sandy Silt w/Mica
4 18 20t 204 Fill -Bed Brown Sandy Silt w/Mica
5' 11 13 12. Fill -Red Brown Sandy Silt w/Mica
-6' G 14 10 Fill -Red Brawn Sandy Silt w/Mica
-7' 20 t 20 t- Residual -Red Brown Sandy Silt w/Mica
* Depth Below Footing Bearing tirade
Note. N, is the average Sat"the second and third DC P readings
Any opinions or recommendations should be based on the field observations made and the tests performed. All hearing grades
should be tree of soft, loose, wet, organic, caved -in soils or otherwise deleterious materials and conditions immediately prior to
the placement of concrete, Exterior foundations should be embedded at least 12-inches below the final exterior grades.
r,,,9, „a-., l", A,,, Lf t,., ra,,," 1 t,,'o'—f - -fence. .:,.,4'( o.,,.n, "..a,,
SINCE
FOUNDATION BEARING GRADE REPORT
project: I [art ['ritertainment permit No: N/A
Client: Building Systems, (Jen. Contr. Date (on -site): 2/23/2004 (Pg. 3)
F&R Representative: W. Goff7R. George/M, Sloan Project No.: E77-141 T
DYNAMIC CONI," PE'NIETRATION TESTS (ASTM S ec a 'Fcc fit ca ['itialication o. -
E. 7
01 3 5 4 Fill -Red Brown Sandy Silt w/Mica
-11 201 201 Fill -Red Brown Sandy Silt w/Mica (1 5' Brown
5 Sot ahweet Corner (Dg rawin-------- Sandy)
Marked SL-SL) -2' 204- 20 1- Fill -Brown Sandy Silt w/Mica
-Y 12 15 1,4 Fill -Brown Sandy Silt w/Mica
4 15 15 15 Residual -Brown Sandy Silt w/Mica
01 8 14 11 Fill -Brown Sandy Silt w/Mica
Front Wall Pier 02 -11 15 15 15 Fill -Brown Sandy Silt w/Mica
6 (Drawing Marked -2' 12 18 15 Fill -Brown Sandy Silt w/Mica
Pier 2-SL)
-Y 10 12 11 Fill -Brown Sandy Silt w/Mica
-T 2W 20+ Residual -Brown Sandy Silt w/Mica
01 12 12 12 Fill -Brown Sandy Silt w/Mica
Front Wall -Small flier on 201- 201 Fill -Brown Sandy Silt w/Mica
`,eft Side; of'llier #4
7 -2' 201 20f Fill -Brown Sandy Silt w/Mica
(Drawing Marked —
Pier 4-S1..) -Y 12 16 14 Residual -Brown Sandy Silt w/Mica
01 8 10 9 Fill -Red Brown Sandy Silt w/Mica
-11 201- 204 Fill -Red Brown Sandy Silt w/Mica
Southeast Corner
8 (Drawing Marked St.-Sl) -21 14 15 15 Fill -Red Brown Sandy Silt w/Mica
-3' 14 15 15 Residual -Red Brown Sandy Silt w/Mica
Depth Below Fooling Bearing; Grade
Note: N, is the average of the second and third DC P readings
Any opinions or recommendations should be based on the field observations made and the tests perfonlied. All hearing grades
ShOUld be free of sofl, loose, wet, organic, caved -in soils or otherwise deleterious materials and conditions immediately prior to
the placement of" concrete. Exterior foundations should be embedded at least 12-inches below the final exterior grades.
- _. _- � - - __ - - A - A -1 t - -1 - __ -A, - A-___ — - - - Cr ------- r___