Loading...
HomeMy WebLinkAboutB3-1902 ENG LTR 2-16-04.PDFFeb 16 04 03:46P Steve KniCht 704--878-2996 P-1 Mr, Tim McCaslin Tim McCaslin Construct- 5245 Peace Haven R d Newton, NC 28658 Where a masonry foundation is used, it should be tied into isting foundation Wall using (2)114" galvanized rod dowels epoxied in the mortar joints of every other Feb 16 04 09:46p Steve Knight 704-878-2996 p.2 course (opposite the joint reinforcing joints)These rods should be 6" long. At th right rear comer, the foundation wall may be a wood stud wall, red to th The top of the foundation walls, whether masonry or wood, must be ancho existing framed walls. Anchors should be installed in the top of the foundation w and tied to the sill plate as required by code. It should not be implied that this report is a comprehensive review or inspection Of aspects of the property. it is only a report of the items specifically addressed herei No assumptions or implications should be made regarding anything that is n covered in this report- I Thank you for allowing me to be of service to you please let me know, Sincerely, BEME12EMM If I may be of further assistanw,