HomeMy WebLinkAboutB3-712 ENG DRAWINGS-2 PGS.PDFm
co
on
yIN'C 1YlEJC N'7
BOND BEAM. TWO *5
BARS (CONTINUOUS)
12' CONCRETE ----�.
BLOCK
LADDER TYPE JOINT
REINFORCEMENT
EVERY COURSE
FILL BLOCK CELLS -11
WITH 3000 PSI CONC.
(TYP. ALL CELLS)
I 6 i. � � d_ 1 t% L p l t/iO
MORTAR C#?
OR CAP BLOCK
NOTE; LEVEL BACKFILL ASSUME
j SPECIAL INDIVIDUAL DESIGN
REQUIRED FOR WALLS WITH
• BACKFILL SLOPING UPWARD
,: • AWAY FROM WALL
'1
*5 BARS 0 IT-" O.C.
WATERPROOF WITH TWO
COATS IHUROSEAL
*6 DOWELS 0 Ito O.C.
• / 4' PE RF . PIPE
FOUNDATION DRAIN
WEEP HOLES wi #67 STONE
36' O.C. BACKFILL WRAPPED
1" SCHED. 40 PVC --._ IN FILTER FABRIC
/*6 BARS l2w O.C.
3' CL. (TYP)
•.r AA
s • . •
*4 BARS 0 120 O.C.
. 1 I. 1 26-80
. - a.
NOTES:
I. CONCRETE SHALL HAVE A MIN, COMPRESSIVE STRENGTH ■ 3LI00 P!
2. REINFORCING STEEL SHALL CONFORM TO ASTM SPECIFICATION
A515, GRADE 60
3. WALL SHALL BE CONSTRUCTED USING RUNNING BOND
SOIL BEARING CAPACITY UNDERNEATH FOOTING SHALL BE
2000 PSF (MIN.)
5. FOOTING SHALL NOT BE PLACED ON FILL
6. MORTAR SHALL BE TYPE S
b * _811 TO 81811 CONCRETE
MASONRY RETAINING WALL
SCALES 3/4'=i°-0•
Ft,TAININC WALL
for
METROMONT MATERIALS, INC.
E
l(
99E569ZSZ6 9Z:91 E00Z/07/60
BOND BEAM, TWO *5
BARS (CONTINUOUS)
12• CONCRETE
BLOCK
LADDER TYPE JOINT
REINFORCEMENT
EVERY COURSE --��
FILL BLOCK CELLS --._
�o WITH 3000 PSI CONC.
® (TYP. ALL CELLS)
F--
0
WEEP HOLES
@ 36. O.C.
I- SCHED. 40 PVC
i +
I`
@4 BARS @ 12. O.C.
MORTAR CAP
OR CAC' BLOCK
a. I
NOTE: LEVEL BACKFILL ASSUMEDI
SPECIAL INDIVIDUAL DESIGN
REQUIRCD FOR WALLS WITH
BACKFILL SLOPING UPWARD
AWAY FROM WALL.
#4 BARS & 24" O.C.
` ;.. WATERPROOF WITH TWO
COATS THOROSEAL
@4 DOWELS @ 24" O.C.
• �` •� 4• PERF. PIPE
FOUNDATION DRAIN
W/ #t67 STONE
..a BACKFILL WRAPPED
IN FILTER FABRIC
1' Et' LAP.*4 BARS @ 12' O.C.
lb
NOTES:
1. CONCRETE SHALL HAVE A MIN. COMPRESSIVE STRENGTH = 3000 PSI
2. REINFORCING STEEL SHALL CONFORM TO ASTM SPECIFICATION
A615, GRADE 60
3. WALL SHALL BE CONSTRUCTED USING RUNNING BOND
SOIL BEARING CAPACITY UNDERNEATH FOOTING SHALL BE
2000 PSF (MIN.)
5. FOOTING SHALL NOT BE PLACED ON FILL
6. MORTAR SHALL BE TYPE S
4 FT. TO 6 FT. CONCRETE
MASONRY RETAINING WALL
SCALE.
z 1109
RtTAINING WALL
for
METROMONT MATERIALS, INC.
C^x Wft V IMT
Iof2
MCCCCC707Q C7 ' 4 T ; MM7. /Cl T /F.A