Loading...
HomeMy WebLinkAboutCBPR-11-10-8442 Hickory First Assembly of God 3rd Submittal.tif 1 a i C6M - I I - b— (by (fZ 8 ►. ,bee rchitect, P.A.. Dallas C. Abee, Jr., AIA ,NCARB 260 First Ave., N.W., Suite 200 February 23 2011 Hickory, North Carolina 28601 www.abeearchitect.com Mr. Bill Rogers Hickory Plan Review Department P. O. Box 398 Hickory, NC 28603 Re: Response to Plan Reviews 9 Building Code Issues Hickory First Assembly of God Church 1301 12 Street Drive, NW, Hickory, NC 28601 Dear Bill: Corrected drawings are enclosed for re- submittal, and the following is my response to Plan Reviews as stated below. Fire Prevention Bureau Review of December 2 1010: (first review) Item #I Drawing Sheet EFP is void. Refer to enclosed Drawing Sheet C -I dated I February 23, 2011. i a Item #2 Refer to enclosed Drawing Sheet A -2 -1 dated February 23, 2011 for construction that existed before work without a permit was performed. Item #3 Refer to Drawing Sheet A -3.1 for Interior Wall and Ceiling Finish Requirements by Occupancy. This is a Class C smoke and flame spread. Note: On Drawing Sheet A -3.1, wallpaper and sheet vinyl shall be removed and Class C i materials installed as per Note on this Drawing. Also, see attached Meeting Notes of February 9, 2011. Item #4 Refer to Drawing Sheet A -3.1 for Door 01 removed. Item #5 Refer to attached letter from Hickory First Assembly of God Church dated February 15, 2011. Items #6, #7, and #8 Refer to Drawings Sheet C -1 dated February 23, 2011 for revised 1 Occupancy content. 1 k -- F Page One of Three P. O. Box 2008, Hickory, NC, 28603 — 828 -322 -1274 p.— 828 - 322 -7356 f. — abeearchitectpa @embargmail.com i CAV - I I - b- cby Yz bee rchitect, P.A. Dallas C. Abee, Jr., ALA ,NCARB 260 First Ave., N.W., Suite 200 February 23 2011 Hickory, North Carolina 28601 www.abeearchitect.com Mr. Bill Rogers Hickory Plan Review Department P. O. Box 398 Hickory, NC 28603 Re: Response to Plan Reviews Building Code Issues Hickory First Assembly of God Church 1301 12 Street Drive, NW, Hickory, NC 28601 Dear Bill: Corrected drawings are enclosed for re- submittal, and the following is my response to Plan Reviews as stated below. Fire Prevention Bureau Review of December 2 1010: (first review) Item #1 Drawing Sheet EFP is void. Refer to enclosed Drawing Sheet C -1 dated f February 23, 2011. Item #2 Refer to enclosed Drawing Sheet A -2 -1 dated February 23, 2011 for construction that existed before work without a permit was performed. c Item #3 Refer to Drawing Sheet A -3.1 for Interior Wall and Ceiling Finish Requirements by Occupancy. This is a Class C smoke and flame spread. Note: On Drawing Sheet A -3.1, wallpaper and sheet vinyl shall be removed and Class C materials installed as per Note on this Drawing. Also, see attached Meeting Notes of February 9, 2011. Item #4 Refer to Drawing Sheet A -3.1 for Door 01 removed. Item #5 Refer to attached letter from Hickory First Assembly of God Church dated February 15, 2011. Items #6, #7, and #8 Refer to Drawings Sheet C -1 dated February 23, 2011 for revised Occupancy content. Page One of Three P. O. Boa 2008, Hickory, NC, 28603 — 828 -322 -1274 p.— 828 - 322 -7356 f. — abeearchitectpa @embargmail.com 4 Z rchitect, P.A. Plan Reviews: Architect's Response Hickory First Assembly of God February 23, 2011 Page Two Fire Prevention Bureau Review of January 20 2011 (second review) Item #1 Refer to Drawing Sheet A -3.1 for Platform Details. Items #2, #3, & #4 Refer to Drawing Sheet A -3.1 for added Life Safety Devices E -1, a E -2, E -3, and E -4. Drawing Sheets A -2 and A -3 are void. Item #5 Letter of Meeting Notes of site visit of February 9, 2011 is attached. Item #9 Drop chords have been removed. Building Inspection Department Review of December 14 2010 (first review) Item #1 Refer to Drawing Sheet C -1 dated February 23, 2011 for the correct Appendix B Data. Drawing Sheet Exist -1 is void. Items #2 & #3 Drawing Sheet EFP is void. Item #4 Refer to Drawing Sheet A -3.1 for New Ramp Details and New Ramp Detail to Platform. Item #5 Drawing Sheet EFP is void. t Item #6 Refer to Drawing Sheet A -3.1 dated February 23, 2011 for added Wall Detail built without approval. Item #7 Refer to Drawing Sheet A -3.1 dated February 23, 2011 for Door 01 removed. Item #8 Refer to attached letter from Hickory First Assembly of God Church dated February 15, 2010, signed by Pastor Polk. Page Two of Three 2. Plan Reviews: Architect's Response Hickory First Assembly of God February 23, 2011 Page Two Fire Prevention Bureau Review of Jan ga 20 2011 (second review) Item #1 Refer to Drawing Sheet A -3.1 for Platform Details. Items #2, #3, & #4 Refer to Drawing Sheet A -3.1 for added Life Safety Devices E -1, E -2, E -3, and E -4. Drawing Sheets A -2 and A -3 are void. Item #5 Letter of Meeting Notes of site visit of February 9, 2011 is attached. Item #9 Drop chords have been removed. Building Inspection Department Review of December 14 2010 (first review) Item #1 Refer to Drawing Sheet C -1 dated February 23, 2011 for the correct Appendix B Data. Drawing Sheet Exist -1 is void. Items #2 & #3 Drawing Sheet EFP is void. Item #4 Refer to Drawing Sheet A -3.1 for New Ramp Details and New Ramp Detail to Platform. Item #5 Drawing Sheet EFP is void. Item #6 Refer to Drawing Sheet A -3.1 dated February 23, 2011 for added Wall Detail built without approval. Item #7 Refer to Drawing Sheet A -3.1 dated February 23, 2011 for Door 01 removed. Item #8 Refer to attached letter from Hickory First Assembly of God Church dated February 15, 2010, signed by Pastor Polk. Page Two of Three 4 3 Plan Reviews: Architect's Response Hickory First Assembly of God February 23, 2011 r Page Three Building Inspection Department Review of January 24 2011 (second review) Item #I Refer to enclosed re- submittal Drawings dated February 23, 2011. Item #2 Refer to Drawing Sheet C -1 for correct A -3 Occupancy. Items #3 & #4 Drawing Sheet A -2 is void. Refer to Drawing Sheet A -3.1 dated February 23, 2011 for Platform Plan Framing and Details. Item #4 Drawing Sheet EFP is void. Item #5 Drawing Sheet A -2 is void. Item #6 Drawings Sheets A -2 and A -3 are void. Items #7 & #8 Refer to letter from Hickory First Assembly of God Church dated February 15, 2011, signed by Pastor Polk. • Sincerely, las . Abee, r., AIANNA Attachments: Re- submitted Revised Drawings, includes Sheet A -2 dated 02/23/11 Architect's Meeting Notes of February 9, 2011 i Letter from Hickory First Assembly of God, dated February 15, 2011 � P RCHlT'F� T ,RED ARC t 0 � '9 X002 ' z C AR �O F NORTH GP r r 3 rchftec ,P.A. Plan Reviews: Architect's Response Hickory First Assembly of God February 23, 2011 Page Three Building Inspection Department Review of January 24 2011 (second review) Item #I Refer to enclosed re- submittal Drawings dated February 23, 2011. Item #2 Refer to Drawing Sheet C -1 for correct A -3 Occupancy. Items #3 & #4 Drawing Sheet A -2 is void. Refer to Drawing Sheet A -3.1 dated February 23, 2011 for Platform Plan Framing and Details. Item #4 Drawing Sheet EFP is void. Item #5 Drawing Sheet A -2 is void. Item #6 Drawings Sheets A -2 and A -3 are void. Items #7 & #8 Refer to letter from Hickory First Assembly of God Church dated February 15, 2011, signed by Pastor Polk. Sincerely, las . Abee, r.; AIA, N Attachments: Re- submitted Revised Drawings, includes Sheet A -2 dated 02/23/11 Architect's Meeting Notes of February 9, 2011 Letter from Hickory First Assembly of God, dated February 15, 2011 pRCHITECi / ,RED A Ecru� q s 1002 zz s ; s + s � s O +, tr .+ y + X O R CAS +„� t oR N c AMR � Q- NORTH GP w 3 5 e Architect P.A. "PLe . Abee, Jr., AIA, NCARB dallasabee @embargmail.com HICKORY FIRST ASSEMBLY OF GOD CHURCH 1301 12'' Street Drive, N.W., Hickory, NC 28601 Our Project #2737 CONFERENCE I Wednesday, February 9, 2011, 2:00 PM Present: Brad Coley, Hickory First Assembly of God Bryan Polk, Hickory First Assembly of God Mark A. Dolphons, Sr., Hickory First Assembly of God Dallas C. Abee, Jr., Architect, Abee Architect Daniel McGalliard, McCarpentry Construction Co. Kelly Davis, Hickory Fire Prevention Jeff Hinkle, Catawba County Building Inspections Bill Rogers, Catawba County Building Inspections 1. Architect requested church write a letter to Jeff Hinkle stating the following: a. No exterior windows installed. b. No mechanical work has been done. c. No electrical work has been done. d. Jeff Hinkle agreed with writing this letter. 2. Kelly Davis stated that the existing fire alarm system in the multi - purpose fellowship hall is not an issue. 3. Dallas Abee stated that this portion of the building is Type III construction. C 4. The platform and walls were installed without a permit. 5. Jeff Hinkle stated that the screen walls rating, flame spread and smoke characteristics are not issues. However, the sheet vinyl is an issue. 6. Jeff Hinkle also stated that the door to exit to the outside stair may be removed. Y 1 Page One of Two t 41• r bee Architect P.A. Dallas C. Abee, Jr., AIA, NCARB dallasabee @embargmail.com HICKORY FIRST ASSEMBLY OF GOD CHURCH 1301 12' Street Drive, N.W., Hickory, NC 28601 Our Project #2737 CONFERENCE Wednesday, February 9, 2011, 2:00 PM Present: Brad Coley, Hickory First Assembly of God Bryan Polk, Hickory First Assembly of God Mark A. Dolphons, Sr., Hickory First Assembly of God Dallas C. Abee, Jr., Architect, Abee Architect Daniel McGalliard, McCarpentry Construction Co. Kelly Davis, Hickory Fire Prevention Jeff Hinkle, Catawba County Building Inspections Bill Rogers, Catawba County Building Inspections 1. Architect requested church write a letter to Jeff Hinkle stating the following: a. No exterior windows installed. '• b. No mechanical work has been done. c. No electrical work has been done. d. Jeff Hinkle agreed with writing this letter. 2. Kelly Davis stated that the existing fire alarm system in the multi - purpose fellowship hall is not an issue. 3. Dallas Abee stated that this portion of the building is Type III construction. 4. The platform and walls were installed without a permit. 5. Jeff Hinkle stated that the screen walls rating, flame spread and smoke characteristics are not issues. However, the sheet vinyl is an issue. 6. Jeff Hinkle also stated that the door to exit to the outside stair may be removed. Page One of Two HICKORY FIRST ASSEMBLY OF GOD CHURCH 1301 12'' Street Drive, N.W., Hickory, NC 28601 Our Project #2737 CONFERENCE Wednesday, February 9, 2011, 2:00 PM Continued 7. Kelly Davis stated that no storage may be in the egress path to the exterior stair. 8. Daniel McGalliard stated that the platform 2 x 8's were installed on the existing VCT flooring. Dallas Abee will provide a complete framing plan of the platform. 9. Kelly Davis stated the following: i a. Remove existing exit sign at door in hall between kitchen and bathrooms. Mark out arrow and install at doorway to outside exit stair. b. Remove exit sign at door to outside stair and install a new exit sign/emergency light combination. C. Install a strobe on fellowship hall side doorway to outside exit stair. d. Install an exit sign/emergency light at door to exterior hall between kitchen and } bathrooms. 10. Dallas to work out a ramp parallel to wall at doorway to outside exit stair and provide full details. Dallas C. Abee, Jr., AIA, NCARB i 260 First Ave., N. W, P.O. Box 2008, Hickory, NC 2 8603—Telephone: 828 - 322 -1274, Fax: 828- 322 -7356 � S HICKORY FIRST ASSEMBLY OF GOD CHURCH 1301 12 Street Drive, N.W., Hickory, NC 28601 Our Project #2737 CONFERENCE Wednesday, February 9, 2011, 2:00 PM Continued 7. Kelly Davis stated that no storage may be in the egress path to the exterior stair. 8. Daniel McGalliard stated that the platform 2 x 8's were installed on the existing VCT flooring. Dallas Abee will provide a complete framing plan of the platform. 9• Kelly Davis stated the following: a. Remove existing exit sign at door in hall between kitchen and bathrooms. Mark out arrow and install at doorway to outside exit stair. b. Remove exit sign at door to outside stair and install a new exit sign/emergency light combination. c. Install a strobe on fellowship hall side doorway to outside exit stair. d. Install an exit sign/emergency light at door to exterior hall between kitchen and bathrooms. 10. Dallas to work out a ramp parallel to wall at doorway to outside exit stair and provide full details. Dallas C. Abee, Jr., AIA, NCARB 260 First Ave., N. W , P.O. Box 2008, Hickory, NC 28 603—Telephone: 828 - 322 -1274, Fax: 828 - 322 -7356 b i a A656EMBLY Of GOD E February 15, 2010 Dear Sirs, As per your request during our meeting on Wednesday, February 9 1h this letter is being issued to you declaring that First Assembly of God of Hickory, Inc. has not had any additional renovations done to our facilities here at 1301 12 Street Drive since our last major renovation project completed in 2005. All work has been done with proper permit. There were questions of windows replaced, mechanical additions, new HVAC installations & electrical work done without permit. As a walk -thru was performed that same day, it was clearly understood that no additional work had been performed without your previous approval with permit. Thank you for coming out to clear up this matter. We are happy to comply with the authorities in all matters pertaining to safety & proper building codes. Pastor Bryan Polk Executive Pastor Hickory First Assembly of God 1301 12th °Street Drive, NW • Hickory, North Carolina 28601 •Tel: 828 - 322 -2040 •Fax: 828 -322 -4535 • www.Hicko F ustAG.org ry i 6 fl ickoly A&SEMBLY Of GOD February 15, 2010 Dear Sirs, As per your request during our meeting on Wednesday, February 9 th this letter is being issued to you declaring that First Assembly of God of Hickory, Inc. has not had any additional renovations done to our facilities here at 1301 12 Street Drive since our last major renovation project completed in 2005. All work has been done with proper permit. There were questions of windows replaced, mechanical additions, new HVAC installations & electrical work done without permit. As a walk -thru was performed that same day, it was clearly understood that no additional work had been performed without your previous approval with permit. Thank you for coming out to clear up this matter. We are happy to comply with the authorities in all matters pertaining to safety & proper building codes. Pastor Bryan Polk Executive Pastor Hickory First Assembly of God 1301 12th Street Drive, NW • Hickory, North Carolina 28601 • Tel: 828 - 322 -2040 • Fax: 828 - 322 -4535 • www.HickoryFirstAG.org