Authorization to Construct Permit
Permit Category: New Wastewater Flow 480 g.p.d
Type of Facility: Primary Residence Bedrooms: 4
Foundation: Crawl space Number of Occupants: 8
Water Supply: New Individual Well Soil LTAR: 0.3 g.p.d./ft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater Q ---------------_._._. _.
System: 25/o REDUCTION
System Classification: IIIG-Other non-conventional trench
systems
Septic Tank: New Tank: #1 1000 gal Grease Trap: gal
#2 gal Pump Specs: GPM@ TDH
#3 gal Draw Down: in
Pump Tank: gal Total Trench Length: 400 ft
Dosing Volume: gal Max.Trench Depth on Downhill 32 in
Sidewall:
Pressure Head: ft Min.Trench Separation: 9 ft on center
Drainfield: Total Area: 1200 sq ft Trench Width: 3 ft
Aggregate
Depth: in
Minimum Soil Cover: 6 in
Number of Drain 6
Lines:
Distribution: Serial
Pre Treatment:
Pump Not Required
Permit Conditions:
-Do not drive,grade,cut or fill over any portion of initial or repair septic areas.
-Install new 1000 gal septic tank and 400 linear feet of 25%reduction product according to manufacturer specifications.
-All septic system components MUST remain 10 feet from property lines,5 feet from building structure,and 50 feet from future well.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system,or prevent proper
drainage away from the septic system,including the direction of gutter flows or foundation drains is not approved,and may result in
failure to approve the initial system installation,or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions < <<
Septic AC 12/15/2023
i •
(.1
4,•4 1CATWBA COUNTY Case# AUTH-231212-03
�`�• Subdivision AVIAN WOODS PH 4
Public Health Department
Environmental Health Division LOT# , 372015648986
al/ PO Box 389,25 Government Dr,tNewton,NC 28658
Site Address: 1141 HARPER LEE DR,NEWTON,NC 28658
Name on Permit: - FAN-WGOD3-LLC Aaron sia payl
Property Size: Acres 0.85 J
Directions: Startown Rd,Right onto Milton St,property on Right
PROPOSED REPAIR
Repair System Required? Required Soil LIAR:0.3 g•p•d./ft2
Proposed Repair System 50%REDUCTION VERTICAL
System Classification: IIIB-Septic system with single effluent pump or siphon
Pump Required
The issuance of this permit by the Health Department does not guarantee the issuance of other permits.It is the responsibility of the applicant
/property owner to ensure that all Catawba County Planning/Zoning and Building Inspection requirements are met.This Improvement Permit
is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered.The Improvement Permit is not
affected by a change in ownership of the property.This permit was issued in compliance with the provisions of the North Carolina 'Laws))and
Regulations for Sewage Treatment and Disposal Systems'(15A NCAC 18A.1900).Neither Catawba County nor the Environmental Health
Specialist warrants that the septic tank system will continue to function satisfactorily for any given period'of time.Any permit issued for a
conventional system may be used for an accepted system without Environmental Health authorization or permit modification.Please notify
Environmental Health of this change prior to system installation.
' 12/12/2023
iiir
Au orized State Permit Issuance Date
Agent
11/14/2028
Permit Expiration
Date
No,grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
*See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system,or prevent proper drainage
away from the septic system,including the direction of gutter flows or foundation drains is not approved,and may result in failure to approve
the initial system installation,or the suspension/revocation of existing permits.
r
Septic AC-Residential 12/12/2023 Page 2