HomeMy WebLinkAboutAUTH-10-2023-205792.TIF 1
%tea CATAWBA COUNTY Case# AUTH-10-2023-205792
.r.lik .Z Public Health Department Subdivision BRADIE WHITE AND OTHER:
d Environmental Health Division PIN# 372416931338
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# PT 3
/8. .
Site Address: 3520 32ND AVE CT NE, HICKORY NC 28601
Name on Permit: DANIEL JARAMILLO-CORONA
Property Size: Acres 0.45
Directions: Springs Rd NE, Left onto 32nd Ave Ct NE
Authorization to Construct Permit
Permit Category: Relocation Wastewater Flow: 480 g.p.d.
Type of Facility: Primary Residence-
Basement? No Basement Plumbing? No Bedrooms: 4
Water Supply: Private Well Maximum Occupants: 8
Soil LTAR: 0.275 g.p.d.lft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25% REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
Septic Tank: New Tank: 1,000 gal
Pump Tank gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 1,314sq ft Total Trench Length: 438 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 34 in
Minimum Soil Cover: 22 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 8 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
*Do not drive, grade, cut or fill over any part of the septic system or repair areas.
*Install new 1000 gal septic tank and 438 feet of 25%reduction product according to manufacturer
specifications.
*Pump, crush, and fill the existing tank at front of the home with soil.
*All septic system components MUST remain 10 feet from property lines, 5 feet from building structure or deck/
porches, and 50 feet from any neighboring well.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: 0.3 g.p.d.lft2
Proposed System: 50%REDUCTION VERTICAL
System Classification: IIIB-SYSTEM W/SINGLE EFFLUENT PUMP
Pump Required
chpermu 10/05/2023 09:17