Loading...
HomeMy WebLinkAboutAUTH-09-2023-205660.TIF �'� CATAWBA COUNTY Case k •��vly�, Al111t-09-2023 205GG0 N it, Public Health Department Subdivision SPRINGHAVEN R` ,tom Environmental Health Division PIN# 374413148007 *• PO Box 389,25 Government Drive.Nev.ton.NC 28658 1.01# 2 fIY tr Site Address: 5215 W PIEDMONT CIR, CONOVER NC 28613 Name on Permit: OLIVIA SMITH Property Size: Acres 0.37 Directions: Take Radio Station Rd to US-321 BUS N/Northwest BIvd,Continue on US-321 BUS N/Northwest Blvd. Take County Home Rd and Lee Cline Rd to Houston Mill Rd Continue on Houston Mill Rd. Drive to W Piedmont Cir,5215 W Piedmont Cir Conover, NC 28613 Owner/Authorized Representative Acknowledgement of Permit Receipt l certify that I am the owner or authorized agent(owner's authorization required)representing the owner of the property described above. s the property owner or authorized representative, I have received the above referenced eflis. permit(s)as requested in the application for service EHPR-09-2023-45579, by the following method(s): Received in Person _ Facsimile Transmittal (Return form with signature required) J- Electronic Image Transmittal/E-mail (Return receipt required) Sts the property owner or authorized representative I have reviewed and understand the specific conditions of the permit issued, and further understand that all applicable regulatory requirements specified under the North Carolina Laws and Rules for Sewage Treatment and Disposal Systems(15A NCAC 18A.1900), and/or Well Construction Standards(15A NCAC 2C.0100), shall apply to the issuance of this permit and the construction of the wastewater system and/or water supply well permitted. Permit Issue Date:09/28/2023 Vs Owner/Authorized Representative Signature_ *IPv ► w 4 _till__ -91 DateAllii_(343 _ . Documentation of Permit(s)Transmittal (permit transmitted by electronic or other means) Permit transmitted by _ _— (name of person sending permit) Signature - _ Ce. Date/Time /O433 Method: Fax J Email US Mail Other Owner's request to send by the above indicated method of transmittal in lieu of signature We wantt tto hear from yoiPlease ttake a few momentts tto complette our custtomer service survey att http://www.su rveymonkey.com/s/EHCu sttomerService tJIi ' 95in i 465,,f.�.a. n ,oIII-L3 chtkmut 09/29/2023 08:49 yyia CATAWBA COUNTY Case# AUTH-09-2023-205660 .1.IL Public Health Department Subdivision SPRINGHAVEN .0C ,� 'i Environmental Health Division PIN# 374413148007 PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 2 Site Address: 5215 W PIEDMONT CIR, CONOVER NC 28613 Name on Permit: OLIVIA SMITH Property Size: Acres 0.37 Directions: Take Radio Station Rd to US-321 BUS N/Northwest Blvd,Continue on US-321 BUS N/Northwest Blvd. Take County Home Rd and Lee Cline Rd to Houston Mill Rd Continue on Houston Mill Rd. Drive to W Piedmont Cir,5215 W Piedmont Cir Conover, NC 28613 Authorization to Construct Permit Permit Category: Repairs Wastewater Flow: 360 g.p.d. Type of Facility: Primary Residence-SFD Basement? Yes Basement Plumbing? Yes Bedrooms: 3 Water Supply: Community Well Maximum Occupants: 6 Soil LIAR: .4 g.p.d.Nt2 WASTEWATER SYSTEM REQUIREMENTS Proposed Wastewater System: 25% REDUCTION System Classification: IIIB-SYSTEM W/SINGLE EFFLUENT PUMP Septic Tank: New Tank: 1,000 gal Pump Tank 1,000 gal Grease Trap_gal Dosing Volume 114 gal Pump Specs: 29.4 GPM @ 21.02 TDH Pressure Head 2 ft Draw Down 5'4 in Drainfield: Total Area: 750 sq ft Total Trench Length: 250 ft Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 25 in Minimum Soil Cover: 6 in Minimum Trench Separation: 7 ft on center Number of Drain Lines: 5 Trench Width: 3 ft Distribution: Pressure Manifold Pre Treatment: NONE Pump Required Additional Specifications: *PRESSURE MANIFOLD: -GATE VALVE REQUIRED -5 SCH 80 1/2"TAPS *INSTALL AS DRAWN *PUMP, CRUSH,AND BACKFILL EXISTING TANK WITH SOIL See also attached site plan. Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and may result in failure to approve the initial system installation, or the suspension/revocation of existing permits. >>>>> Do not install system under wet conditions <<<<< PROPOSED REPAIR Repair System Required? Soil LTAR: g.p.d./ft2 Proposed System: System Classification: thpermit 10/04/2023 13:37