HomeMy WebLinkAboutAUTH-09-2023-205549.TIF % * CATAWBA COUNTY Case# AUTH-09-2023-205549
.�. ,Z Public Health Department Subdivision SOUTH LAKES DEV PHASE 1
i. Environmental Health Division PIN# 363918417689
PO Box 389,25 Government Drive,Newton,NC 28658 I,OT# 6
18 w
Site Address: 2110 EVERGREEN DR, NEWTON NC 28658
Name on Permit: NANCY VANG
Property Size: Acres 0.56
Directions: Right off of McKay Rd onto Evergreen Dr. 6th lot on left on corner of Evergreen and Heron.
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 480 g.p.d.
Type of Facility: Primary Residence-
Basement? No Basement Plumbing? NO Bedrooms: 4
Water Supply: Public Water Maximum Occupants: 8
Soil LIAR: 0.3 g.p.ddit2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 50% REDUCTION VERTICAL
System Classification: IIIE- PPBPS GRAVITY DOSED SYSTEM
Septic Tank: New Tank: 1,000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 804 sq ft Total Trench Length: 267 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 34 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 6 ft on center
Number of Drain Lines: 6 Trench Width: 2 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
*Do not drive,grade, cut or fill over any part of the septic system or repair areas.
*Install new 1000 gal septic tank and 267 feet of 50% reduction panel block system according to manufacturer
specifications.
*Each septic line will contain 11 panels(with the exception of the 32'line which will contain 7 panels).
*All parts of the septic system area MUST remain 10 feet from property and water lines, and 5 feet from building
structure.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: 0.3 d.lft2
9•P-
Proposed System: 50%REDUCTION VERTICAL
System Classification: IVA-ANY SYSTEM WITH LPP DISTRIBUTION
Pump Required ***** Operator Required
� , 1 09/28/2023 09:13
Catawba County Environmental Health
g g R6Pt - o5- zozz - N119y
$ •sooe 7mPv-09 - zoza— 1 yqo
AA, -01- Zo a 3- 2°5. 1'
--4 'IL , _�
ce
7z r 209.31 300.87
as 32
tot
nroD rt`y� VO
1 i ' -, . . lea
a Q f3 10
gei g? VI
I W��
w pp
D°X � , `LrN
0 CC 1.)
�
51 7
'u ' I
41.67 ..1 10 -7
• A4;;ata1 V(AI 11u5t
CP
N.
If/ 0 / __r Ra y, S
so,
•910'
A \
°V e
N.
/17 Cr
al
K\\\ 40
Parcel; 363918417689, 2110 EVERGREEN DR 1in=40ft
NEWTON, 28658
Ths mop/report product was prepared from the Catawba County.NC Oaospattal Information Services. Catawba County has made substantial efforts
toovum the aoa racy Of location and labeling Information contained on this map or data on this report.Catawba County promotes and recommends
the independent v iMca ion of any data opMatned on Oils rnapirsport product by the user.The County of Catawba,Its employees,agent,and
personnel.diocesan,and shall rot be hatd liable for any and aN damages,loss or liability,whathsr direct.Indirect or consequential which arises or may
seas from the map/report product or the use thereof by any parson or entity.
Copyright 2023 Catawba County NC
09/27/2923