Loading...
HomeMy WebLinkAboutAUTH-09-2023-205549.TIF % * CATAWBA COUNTY Case# AUTH-09-2023-205549 .�. ,Z Public Health Department Subdivision SOUTH LAKES DEV PHASE 1 i. Environmental Health Division PIN# 363918417689 PO Box 389,25 Government Drive,Newton,NC 28658 I,OT# 6 18 w Site Address: 2110 EVERGREEN DR, NEWTON NC 28658 Name on Permit: NANCY VANG Property Size: Acres 0.56 Directions: Right off of McKay Rd onto Evergreen Dr. 6th lot on left on corner of Evergreen and Heron. Authorization to Construct Permit Permit Category: New Septic Wastewater Flow: 480 g.p.d. Type of Facility: Primary Residence- Basement? No Basement Plumbing? NO Bedrooms: 4 Water Supply: Public Water Maximum Occupants: 8 Soil LIAR: 0.3 g.p.ddit2 WASTEWATER SYSTEM REQUIREMENTS Proposed Wastewater System: 50% REDUCTION VERTICAL System Classification: IIIE- PPBPS GRAVITY DOSED SYSTEM Septic Tank: New Tank: 1,000 gal Pump Tank _gal Grease Trap_gal Dosing Volume gal Pump Specs: GPM @ TDH Pressure Head ft Draw Down in Drainfield: Total Area: 804 sq ft Total Trench Length: 267 ft Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 34 in Minimum Soil Cover: 6 in Minimum Trench Separation: 6 ft on center Number of Drain Lines: 6 Trench Width: 2 ft Distribution: Serial Pre Treatment: NONE Additional Specifications: *Do not drive,grade, cut or fill over any part of the septic system or repair areas. *Install new 1000 gal septic tank and 267 feet of 50% reduction panel block system according to manufacturer specifications. *Each septic line will contain 11 panels(with the exception of the 32'line which will contain 7 panels). *All parts of the septic system area MUST remain 10 feet from property and water lines, and 5 feet from building structure. See also attached site plan. Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and may result in failure to approve the initial system installation, or the suspension/revocation of existing permits. >>>>> Do not install system under wet conditions <<<<< PROPOSED REPAIR Repair System Required? Required Soil LTAR: 0.3 d.lft2 9•P- Proposed System: 50%REDUCTION VERTICAL System Classification: IVA-ANY SYSTEM WITH LPP DISTRIBUTION Pump Required ***** Operator Required � , 1 09/28/2023 09:13 Catawba County Environmental Health g g R6Pt - o5- zozz - N119y $ •sooe 7mPv-09 - zoza— 1 yqo AA, -01- Zo a 3- 2°5. 1' --4 'IL , _� ce 7z r 209.31 300.87 as 32 tot nroD rt`y� VO 1 i ' -, . . lea a Q f3 10 gei g? VI I W�� w pp D°X � , `LrN 0 CC 1.) � 51 7 'u ' I 41.67 ..1 10 -7 • A4;;ata1 V(AI 11u5t CP N. If/ 0 / __r Ra y, S so, •910' A \ °V e N. /17 Cr al K\\\ 40 Parcel; 363918417689, 2110 EVERGREEN DR 1in=40ft NEWTON, 28658 Ths mop/report product was prepared from the Catawba County.NC Oaospattal Information Services. Catawba County has made substantial efforts toovum the aoa racy Of location and labeling Information contained on this map or data on this report.Catawba County promotes and recommends the independent v iMca ion of any data opMatned on Oils rnapirsport product by the user.The County of Catawba,Its employees,agent,and personnel.diocesan,and shall rot be hatd liable for any and aN damages,loss or liability,whathsr direct.Indirect or consequential which arises or may seas from the map/report product or the use thereof by any parson or entity. Copyright 2023 Catawba County NC 09/27/2923