HomeMy WebLinkAboutAUTH-09-2023-204673.TIF •
CATAWBA COUNTY Case# AU1'f{-09-2023 204673
.�.ttittt
Public Health Department Subdivision
Environmental Health Division PIN 376007678559
PO Box 389.25 Government Drive,Newton,NC 28658 LOT# 1A
alit w
Site Address: 3681 E NC 10 HWY, CLAREMONT NC 28610
Name on Permit: BRADLEY CAMPBELL
Property Size: Acres 5.239
Directions: Radio Station Rd, right onto 321 S Bus/Southwest Blvd, left onto NC 10/W C St, keep right to stay on NC 10/
WD St left onto NC 10/E NC 10 Hwy, keep right to stay on NC 10/NC Highway 10, property on the right
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence-New Home
Basement? No Basement Plumbing? No Bedrooms: 3
Water Supply: Public Water Maximum Occupants: 6
Soil LIAR: .275 g.p.d.Ift2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25% REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
Septic Tank: New Tank: 1,000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: sq ft Total Trench Length: 328 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 28 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 4 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved,and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions<<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: .275 9•P•d.Ift2
Proposed System: 25%REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
eiit unit I0.;03 2023 I5S0