HomeMy WebLinkAboutAUTH-08-2023-203544.TIF a
,F'.:. • CATAWBA COUNTY Case# AUTH-08-2023-203544
d i Public Health Department Subdivision MEADOWBROOK VILLAGE P
i Environmental Health Division PIN# 279010467506
A\ s PO Box 389,25 Government Drive,Newton,NC 28658 LOT/ 6
&IV y
Site Address: 1335 FIELDCREST DR, HICKORY NC 28602
Name on Permit: ALEX ROPER
Property Size: Acres .350
Directions: S NC 127 Hwy right Valley Field Rd, right Fieldcrest Dr, 2nd on left
Owner/Authorized Representative Acknowledgement of Permit Receipt
I certify that I am the owner or authorized agent(owner's authorization required)representing the owner of
the property described above.
As the property owner or authorized representative, I have received the above referenced
permit(s)as requested in the application for service EHPR-05-2023-44314, by the following method(s):
Received in Person
Facsimile Transmittal (Return form with signature required)
jElectronic Image Transmittal/E-mail (Return receipt required)
1 As the property owner or authorized representative I have reviewed and understand the specific conditions
of the permit issued, and further understand that all applicable regulatory requirements specified under the
North Carolina Laws and Rules for Sewage Treatment and Disposal Systems(15A NCAC 18A.1900),
and/or Well Construction Standards(15A NCAC 2C .0100), shall apply to the issuance of this permit and
the construction of the wastewater system and/or water supply well permitted.
Permit Issue Date: 08/28/2023
Owner/Authorized Representative Signature
Date
Documentation of Permit(s)Transmittal
(permit transmitted by electronic or other means)
Permit transmitted by _ (name ofperson sending permit)
Signature_ 4E. Date/Time 514)3
Method: Fax J Email US Mail Other
Owner's request to send by the above indicated method of transmittal in lieu of signature
We wantt tto hear from yotPlease ttake a few momentts tto complette our custtomer servic69,,,,j.e survey att
http://www.su rveymonkey.com/s/EH Custtomerservice
'riot
ehpenniI 08/29/2023 08:42
3,$% . CATAWBA COUNTS Case!t AUTH-08-2023-203544
'(.....
j.a ,, Public Health Department Subdivision MEADOWBROOK VILLAGE P
S �! 'H Environmental Health Division PIN» 279010467506
PO Box 389,25 Government Drive,Newton,NC 28658 I.OTO 6
; .2 i.
Site Address: 1335 FIELDCREST DR, HICKORY NC 28602
Name on Permit: ALEX ROPER
Property Size: Acres .350
Directions: S NC 127 Hwy right Valley Field Rd. right Fieldcrest Dr, 2nd on left
Authorization to Construct Permit
Permit Category: Repairs Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence- Existing house
Basement? Yes Basement Plumbing? Yes Bedrooms: 3
Water Supply: Public Water Maximum Occupants: 3
Soil LTAR: _0.25 g.p.d.lft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: CONVENTIONAL
System Classification: IIA-CONV SYSTEM(SINGLE-FAMILY OR 480 GPD OR LESS)
Septic Tank: New Tank: 1,000 gal
Pump Tank 1,000 gal Grease Trap_gal
Dosing Volume 114 gal Pump Specs: 23 GPM @ TDH
Pressure Head ft Draw Down 5.4 in
Drainfield: Total Area: 750 sq ft Total Trench Length: 50 ft
Aggregate Depth: 12 in Maximum Trench Depth on Downhill Sidewall: 12 in
Minimum Soil Cover: 6 in Minimum Trench Separation: ft on center
Number of Drain Lines: Trench Width: 15 ft
Distribution: Distribution Box
Pre Treatment: NONE
Pump Required
Additional Specifications:
*Install new 15'x 50'gravel bed
*Pump to washer box with a 90 degree downward turn into the washer box. 3"pipe out of the washer box into a
distribution box.
*The gravel bed must be a minimum of 10'from the house and 5'from property lines.
*Gravel bed is not a full repair for 3 bedrooms
*Cover will need to be brought in to meet minimum 6 inches
*Trees in the front yard will need to be removed, and their stumps removed, prior to installation of the system
*This system square footage is undersized for 3 bedrooms by current standards. All available space was used.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Soil LTAR: g.p.d./ft2
Proposed System:
System Classification:
iy, ;un1 09/012023 16:35