HomeMy WebLinkAboutAUTH-08-2023-202413.TIF CATAWBA COUNTY Case#
Subdivision
PIN#
AUTH 08 2023 202413
• IA ,y Public Health Department
Environmental Health Division 279005184709
1
PO Box 389,25 Government Drive,Newton,NC 28658 LOT#
w
Site Address: 3611 S NC 127 HWY, HICKORY NC 28602 i� �'} 7 L� ���
Name on Permit: GATE INVESTMENTS LLC / I -LI ( r)033A [��(.R�`�
Property Size: Acres 1.74
Directions: Hwy 127 S on right just past Mountain Grove Church Rd
Authorization to Construct Permit
Permit Category: EX FAIISi pn Wastewater Flow: 550 g.p.d.
Type of Facility: Business-Salon and storage building business
Basement? No Basement Plumbing? No Bedrooms:
Water Supply: Public Water Maximum Occupants:
Soil LTAR: 0.275 g.p.d.lft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25% REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
Septic Tank: Existing Tank 1,000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: sq ft Total Trench Length: 46 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 30 in
Minimum Soil Cover: 12 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 1 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
*46'of chambers to be added to existing 42'line as shown on the site plan.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains,is not approved, and
may result in failure to approve the initial system installation,or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions<<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: 0.275g.p.d.lft2
Proposed System: 50%REDUCTION HORIZONTAL
System Classification: IVA-ANY SYSTEM WITH LPP DISTRIBUTION
Pump Required ***** Operator Required
ehperoiil 08/11/2023 08:29
e CATAWBA COUNTY Case# AUTH-08-2023-202413
• t. Public Health Department Subdivision
Environmental Health Division PIN# 279005184709
NolPO Box 389,25 Government Drive,Newton,NC 28658 LOT# 1
: sw
Site Address: 3611 S NC 127 HWY, HICKORY NC 28602
Name on Permit: GATE INVESTMENTS LLC
Property Size: Acres 1.74
Directions: Hwy 127 S on right just past Mountain Grove Church Rd
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant
/property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to
Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to
Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the
North Carolina'Laws and Rules for Sewage Treatment and Disposal Systems' (15A NCAC I 8A.1900). Neither Catawba County nor the
Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time.
Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit
modification.Please notify Environmental Health of this change prior to system installation.
1 kee ee.k 43
oarl o/2ozs
Authorized State Agent Permit Issuance Date
8/10/2028
Permit Expiration Date
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
chpemdt 08/11/2023 08:29
. „ . . . . . . . ..,.. . .. . ' ' . ..
:' 'Z' '' • ., . .. „.., ,. , . ..
.. •.
mil.m. •
Catawba County Environrrentall-leaith .
. . . .
• .
.....• .
. . . ..•.. . . .
. , .
• . .•
OPP- 01' 2 0,25 , 14,500.5- • .
• 1 mpy- og• - 02. - vopst-iio . .
.'
• ' ALAI"14 - 0 g- 2 0%Z3 ; (.1() 1-1 1 3 . .. ..•••
.: •
. .. •
. . .... •"
• ., .: . ...• .
. - . ..
. . •... .
. . ..
• 1 .,r1
e.,1 4'..11.1.1. . . • .. . ......
„,..„.....:,•-. ,..:7''' 9r*... • v:1.0., . • .•,.‹: -• ...
- .
. •
. • .. ., .
• .
. .
,;-: ... •4' . ...', . ..,` . •• '... .....,- _'1,.,-:,-- .. •
. . iri! " ...• ' .'; : •. -: . .
• • • . • •• • . • ••
• . •. .:....A - 46'. . . - A .. • ' • . "; -. . .. ... : - ., . . .
. .. • -, :.". - ,t itt-;iltv . ••.
• . ,
,. . . .. :. . . . . .
.. .• • ., . • .
•
•
0 .: .• ?.• '..'•••4. :-.C.'-'::'.: :..-•1°. ' s 361 i... • 00 •
•.,.... • .
• L. <.,:,:',-, ' - ' ..... •; . e... : -. ii36.1.g. • ... i .
- .•
, ', •-.
- 'if - • , • : i, 1
..., . 7 .r • •
. • ... - • -
: ........ • 7
•
:7, •
• - , i . • ' . • .• . • -• 7'
•• • :.: .
.: • .
• • !;. Lii,`of- . ;- • ....."• • • . .
• .
. •
pi •
. . .• •c-1,-.t,rdo.a.r.,-..3-- •
, • iq ...
• ci' vritt4 A .., , .• . . ... .
.- •
i• .
• • • s• . -.f '0,i4ee4 4-0 .
.
• o : •
.:,, . .. ... '
• ''. e 45-4-1 fi5 V •• : . .
: . • .
i•
• ' •:. I-12! . ,.... ... .". • • •••• ' '
. •7.. .. • , Afi ..:'... - . •
• 1513.717'
• • . •..; '
. . •, .. •,. - . •
. . ,• .
. . • •
•
• : • *:, . . .., .„ , . , I .. ..
. .
• A . • r
. . ... . .. . •. .. ..• ,
•
1 . . ' • .. . „
*/.. • ,''' C) ..Z A Itr holt
• . . . .• . •,, . . . .0.11,. .
.•
.. ., ... . • . ; i C).T. 6,- r sc;\ p;'+
. - . •• :". .... 1‘..•;::,,.."
•
• •_. •. .., .• • -:. n
•
• . . •
•-•.,:-,..:-,--.......,r;•...,,,),..A.,-...__,,-.._,, ....-• „. : ', . _.,.-...: ..-:-..1.,.
ift,2791305,1847Q9"1".361fS'NO.127....HWY' lin=-:40fi
OAi•t"8-8 4 --.. • •
,',_1 02':: - • • •• . .
'i•-•••••;*y-';':::.• '1.1.. ' :.'• -. • • • -
;•..'i•:. :-,• - ': •'. •• • . .
,.-,. : •.:,-...,:..-.•--. • - . .
• . -.• ,.. - . .... .• • .
•
•
.,, ,,:',)-'4.,..ilikki--licii.. ...r?'•'i-.-';;*....,•V-i....".. .•:"?: ••-. .' ''.4-1:•.? ' • • .. • '
witPilaired froln e.18 CatoviebACZystedGeoCittil IrgornlatioriServIcsix";•:Cattfiba County t'033 Made sikstatild titivts .
WiegfeetivotitiocatiOn,iind -Aionnittion• .. .. an. :map Cif dal ors.thls rapbrOlitiifibliCourIty.p5pates end fecornmendi .
V0244.4pciberfcatixip Een ' fdati''" 'ORM*Map/report prixtilct by MO tisivitte County oftetaviba,Ibi employe:wag/Oa;and '
,``arrtribil - .bistefd:liable.fotjalY and aU atiranteaticia"fca.110qtyp4Voilether•direct,IndrectOr consequential which adios or may
it Oa. Pi:dle Ostrulf by
-,':. ••:. ': . •''. 7:: 1- '.•• '•• : . •• • .Comte,*2021 Catawba Ciatiy tIC
• .06/13/2022
...*:,.•..;:!..7.',1%,'I:.,:*:': ..: ::: f:..1'..'....;:'. •:-.. -.
CATAWBA COUNTY Case# AUTI I-08-2023-202413
Public Health Department Subdivision
Environmental Health Division PIN# 279005184709
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 1
8 sm
Site Address: 3611 S NC 127 HWY, HICKORY NC 28602
Name on Permit: GATE INVESTMENTS LLC
Property Size: Acres 1.74
Directions: Hwy 127 S on right just past Mountain Grove Church Rd
Authorization to Construct Permit
Permit Category: Repair/Expansion Wastewater Flow: 550 g.p.d.
Type of Facility: Business-Salon and storage building business
Basement? No Basement Plumbing? No Bedrooms:
Water Supply: Public Water Maximum Occupants:
Soil LTAR: 0.275 g,p,d./ft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25% REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
Septic Tank: Existing Tank 1,000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: sq ft Total Trench Length: 46 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 30 in
Minimum Soil Cover: 12 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 1 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
*46'of chambers to be added to existing 42' line as shown on the site plan.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: 0.275 d.1ft2
9•P•
Proposed System: 50%REDUCTION HORIZONTAL
System Classification: IVA-ANY SYSTEM WITH LPP DISTRIBUTION
Pump Required ***** Operator Required
clqrnn� 08/11/2023 08:29