HomeMy WebLinkAboutAUTH-07-2023-200720.TIF SBA • CATAWBA COUNTY Case# AUTH-07-2023-200720
t 1, Public Health Department Subdivision PEBBLE BAY PH 5
l F Environmental Health Division PIN# 460601257686
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 216
1842 w
Site Address: 7268 JAMES CT, DENVER NC 28037 A6pRqfrv)3-ipt0
Name on Permit: ANDREA MUELLER
Property Size: Acres 1.51
Directions: going north on Campground Rd/left Catawba Burris/right Bankhead/right Bay View/left James Ct(gate
number 2877)
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 100 g.p.d.
Type of Facility: Accessory Structure-
Basement? No Basement Plumbing? No Bedrooms:
Water Supply: - ate-We1L Maximum Occupants:
CPA Wn"1y 114 Soil LTAR: 0.3 g.p.dJft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25%REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
Septic Tank: New Tank: 1 000 gal
Pump Tank gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 246 sq ft Total Trench Length: 84 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 34 in
Minimum Soil Cover: 12 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 2 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved,and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions<<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: 0.3 g.p.dift2
Proposed System: 25%REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
ehpennit 07/27/2023 05:47