HomeMy WebLinkAboutAUTH-07-2023-199600.TIF CATANBACOUNTY Case A1JTIl-07-2023-199600
Public Health Department Subdivision HIGHLAND GLEN
Environmental Health Division PIN# 368702959342
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 29-30
/8.2
Site Address: 3717 CARIBOU DR, SHERRILLS FORD NC 28673
Name on Permit: ELLIOT ROTHMAN
Property Size: Acres 1.5
Directions: Mt Beulah Rd/Lineberger Rd/Caribou Dr/lot on right
Authorization to Construct Permit
Permit Category: Expansion Wastewater Flow: 600 g.p.d.
Type of Facility: Prim Res/Acc Dwelling-existing 3 Br, 2Br MH accessory
Basement? No Basement Plumbing? No Bedrooms: 5
Water Supply: Private Well Maximum Occupants: 10
Soil LTAR: 0.275 g.p.dift2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25% REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
Septic Tank: New Tank: 1.500 gal
Pump Tank gal Grease Trap_gal
Dosing Volume _ gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 666 sq ft Total Trench Length: 222 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 30 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 3 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
*Expansion from 3 Br(permit#06293, dated 10/20/93)to 5 Br septic system(adding a 2 Br MH) .
*Do not cut,drive,fill, or grade over septic or repair areas.
*Septic system must be 10 ft from property lines, minimum 50 feet from shared well(but as far as possible), 5 ft
from building foundations and appurtenances, and out of right-of-ways and easements.
*Install a new 1,500 gallon septic tank(risers required if top of tank is greater than 6 inches below land surface).
Existing septic tank should be pumped out, crushed, and filled in with soil.
`After septic tank install a new 5 outlet distribution box. 3 outlets should feed the existing lines and the other 2
outlets should feed the new lines.
`Install 222 linear feet of 25% reduction system, proposed 3 lines at 74 ft each on contour.
`Final grade of septic area must shed surface water off and away from system.
'All gutter drains must be routed away from the septic system.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved,and
may result in failure to approve the initial system installation. or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LIAR: 0.25 g.p.d.Ift2
rhprn,Ln 07/19/2023 08:27
44r�• CATAWBA COUNTY Case AUTH-07-2023-199600
ti .i.k•
Public Health Department Subdivision HIGHLAND GLEN
"4 Environmental Health Division PIN# 368702959342
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 29-30
IH.2�s�
Site Address: 3717 CARIBOU DR, SHERRILLS FORD NC 28673
Name on Permit: ELLIOT ROTHMAN
Property Size: Acres 1.5
Directions: Mt Beulah Rd/Lineberger Rd/Caribou Dr/lot on right
Proposed System: 50%REDUCTION HORIZONTAL
System Classification: IVA-ANY SYSTEM WITH LPP DISTRIBUTION
Pump Required ***** Operator Required
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant
/property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to
Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to
Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the
North Carolina'Laws and Rules for Sewage Treatment and Disposal Systems' (I 5A NCAC I8A.1900). Neither Catawba County nor the
Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time.
Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit
modification.Please notify Environmental Health of this change prior to system installation.
f
07/18/2023
Authorized State Agent Pennit Issuance Date
7/18/2028
Pennit Expiration Date
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
ehpennil 07/19/2023 08:27