HomeMy WebLinkAboutAUTH-07-2023-200126.TIF 44, • CATAWBA COUNTY
F� Ilit Public Health Department Subdivision MUNDY ACRES PHASE III
d lal Environmental Health Division PIN# 369604813951
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 25
/842 tw
Site Address: 5112 LINEBERGER LOOP RD, DENVER NC 28037
Name on Permit: THOMAS GRIFFIN
Property Size: Acres 1.36
Directions: NC 16, left onto Campground Rd, left on Catawba Burns Rd, Left on Lineberger Rd. Keep Straight to get on
Lineberger Loop Rd, Property on Right
Owner/Authorized Representative Acknowledgement of Permit Receipt
1 1 certify that I am the owner or authorized agent(owner's authorization required)representing the owner of
the property described above.
F As the property owner or authorized representative, I have received the above referenced
permit(s)as requested in the application for service RBPR-06-2023-44530,by the following method(s):
Received in Person
Facsimile Transmittal (Return form with signature required)
J Electronic Image Transmittal/E-mail (Return receipt required)
C As the property owner or authorized representative I have reviewed and understand the specific conditions
of the permit issued, and further understand that all applicable regulatory requirements specified under the
North Carolina Laws and Rules for Sewage Treatment and Disposal Systems(15A NCAC 18A.1900),
and/or Well Construction Standards(15A NCAC 2C.0100), shall apply to the issuance of this permit and
the construction of the wastewater system and/or water supply well permitted.
Permit Issue Date: 07/14/2023
Owner/Authorized Representative Signature
Date
Documentation of Permit(s) Transmittal
(permit transmitted by electronic or other means)
Permit transmitted by (name ofperson sending permit)
Signature Date/Time —7J 77 j)3
Method: Fax J Email US Mail r Other
Owner's request to send by the above indicated method of transmittal in lieu of signature
We wantt tto hear from yotPlease ttake a few momentts tto complette our custtomer service survey aft
http://www.surveymonkey.com/s/EHCusttomerservice
Za01169• CIQI) Clagin% h .444
ehpennit 07/17/2023 14:08
,y,A CATAWBA COUNTY1...,( Case# AUTH 07 2023 200126
.f. Z Public Health Department Subdivision MUNDY ACRES PHASE III
Q Environmental health Division PIN# 369604813951
PO Box 389,25 Government Drive,Newton,NC 28658 LO'I'N 25
184
5�Hy
Site Address: 5112 LINEBERGER LOOP RD, DENVER NC 28037
Name on Permit: THOMAS GRIFFIN
Property Size: Acres 1.36
Directions: NC 16, left onto Campground Rd, left on Catawba Burris Rd, Left on Lineberger Rd, Keep Straight to get on
Lineberger Loop Rd, Property on Right
Authorization to Construct Permit
Permit Category: Expansion Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence-
Basement? No Basement Plumbing? No Bedrooms: 3
Water Supply: Public Water Maximum Occupants: 6
Soil LTAR: 0.275 g.p.d.ft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 50% REDUCTION VERTICAL
System Classification: IIIE-PPBPS GRAVITY DOSED SYSTEM
Septic Tank: New Tank: 1,000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 234 sq ft Total Trench Length: 78 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 35 in
Minimum Soil Cover: 12 in Minimum Trench Separation: 8 ft on center
Number of Drain Lines: 3 Trench Width: 2 ft
Distribution: Distribution Box
Pre Treatment: NONE
Additional Specifications:
'INSTALL(3)26'TRENCHES FED FROM NEW DISTRIBUTION BOX.6 PANELS PER TRENCH. 18 PANELS
TOTAL.
*2/3 EFFLUENT GOES TO EXISTING BED AND 1/3 EFFLUENT GOES TO PANEL LINES FED EQUALLY.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation. or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions ««<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: 0.3 9-p•d./ft2
Proposed System: 50%REDUCTION HORIZONTAL
System Classification: IIIE-PPBPS GRAVITY DOSED SYSTEM
Pump*May Be* Required
07'21:2023 08.10