Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RBPR-07-2023-44891.TIF
• A 6P.07 )0)3 11'186 1 yoF ,�;,•.,,,, ho ROY COOPER Governor " , • NC DEPARTMENT OF KODY H. KINSLEY• Secretary gW" iI1kW ' ES EATH AND HELEN WOLSTENHOLME• Interim Deputy Secretary for Health ,E v .` MARK T. BENTON•Assistant Secretary for Public Health Division of Public Health COMMON FORM FOR AUTHORIZED ON-SITE WASTEWATER EVALUATOR PERMIT OPTION FOR NON-ENGINEERED SYSTEMS See instructions for Use in Appendix A Except for"Date received",this Section to be completed by the AOWE in accordance with G.S.130A-336.2 LHD USE ONLY: Initial submittal of this NOl received: by Date Initials PART 1:Notice of Intent to Construct(NOI)-Please check all that apply ®Single System or ❑ Multiple Systems AND ®New ❑ Expansion ❑ Relocation of all or part of the Existing System ❑ Relocation of Repair Area ❑ Repair—LHD Permit Number ❑ Repair—EOP/LSS COVID 19/AOWE Permit Number 1. Facility Owner's name:(Owner, Company Name, Utility, Partnership, Individual, etc.): Adams Homes-AEC, LLC Mailing address: 3401 St. Vardell Lane, Suite B City: Charlotte State: NC Zip: 28217 Telephone number: 704-558-4527 E-mail Address: bcashionadamshomes.com 2. Authorized On-Site Wastewater Evaluator(AOWE) name: Jeff Vaughan LSS License number:1227 AOWE Certification number:10003E Mailing address:501 N Salem St, Suite 203 City:Apex State: NC Zip: 27502 Telephone number: 919-859-0669 E-mail Address: Ivaughan@agriwaste.com 3. Licensed Geologist(LG)(if applicable) name: License Number: Mailing address: City: State: Zip: Telephone number: E-mail Address: 4. Proof of Errors and Omissions or other appropriate liability insurance for the following persons is attached that includes the name of the insurer, name of the insured and the effective dates of coverage: ®AOWE ❑ LG 5. Property location(physical address,tax parcel identification number or subdivision lot, block number of the property to be permitted Lot 22 Penarth Drive, Catawba, NC. 28609 (Cardiff Glyn Subdivision) County Name: Catawba RECEIVED NC DEPARTMENT OF HEALTH AND HUMAN SERVICES • DIVISION OF PUBLIC HEALTH U III q 4 2023 LOCATION*5605 Six Forks Road,Raleigh,NC 27609 L I MAILING ADDRESS:1642 Mail Service Center,Raleigh,NC 27699-1642 www.ncdhhs.gov • TEL:919-707-5874 • FAx 919-845-3972 Environmental Health AN EQUAL OPPORTUNITY!AFFIRMATIVE ACTION EMPLOYER AOWE Common Form LHD Reference: 6. Type of facility: X Place of residence No. Bedrooms: 3 No. Occupants:6 Place of business Basis for flow calculation: ❑ Place of public assembly Basis for flow calculation: 7. Factors that would affect the wastewater load:domestic strength wastewater from a single-family residence 8. Type and location of proposed wastewater system: Pressure Manifold 25% Reduction drain field product Location shown on site plan 9. Design wastewater flow: 360 gpd Design wastewater strength: ® domestic ❑ high strength ❑ industrial process(For high strength and industrial process wastewater,a Professional Engineer licensed in accordance with G.S.89C shall design the on-site wastewater system.) 10. A plat as defined in G.S. 130A-334(7a)is attached: ❑Yes ® No A site plan as defined in G.S. 130A-334(13a)is attached: k Yes No 11. Location of proposed or existing wells(drinking water, irrigation,geothermal,groundwater monitoring, sampling, etc.) and any potable and non-potable water conveyance lines is indicated on attached plans and complies with 15A NCAC 18A.1950: ®Yes ❑ No This is a saprolite system. ❑Yes k No 12. Evaluation(s) of soil conditions and site features in accordance with G.S. 130A-335(a1)signed and sealed by a LSS is attached: ®Yes ❑ No 13, Evaluation of geologic and hydrogeologic conditions signed and sealed by a LG is attached [ Yes ® NA 14. Proposed landscape,site,drainage,or soil modifications are attached: ❑Yes ® NA Attestation by AOWE pursuant to G.S.130A-336.2 I, Jeff Vaughan hereby attest that the information required to be included with Authorized On-Site Wastewater Evaluator(Print Name) this Notice of Intent to Construct is accurate and complete to the best of my knowledge and that the proposed system shall meet applicable federal, State, and local laws, regulations, rules and ordinances, and that the proposed system does not require a Professional Engineer, licensed in accordance with G.S.89C,and in accordance with 15A NCAC 18A.1938 and activities determined to be engineering as determined by the North Carolina Board of Examiners for Engineers and Surveyors. June 20, 2023 Signature of Authorized On-Site Wastewater Evaluator Date Owner self-submittal of NO!: I, hereby submit this NOI prepared by Print Name of Owner Print Name of Licensed PE pursuant to G.S. 130A-336.1. Signature of Owner Date DNNS/ENS/OSWP—AOWE COMMON FORM Updated April 2022 Page 2 of 6 AOWE Common Form LHD Reference: NOTES: LIABILITY: The Department, the Department's authorized agents,or local health departments shall have no liability for wastewater systems designed,constructed,and installed pursuant to an AOWE Permit Option[G.S.130A-336.2(f)] RIGHT OF ENTRY: The submittal of this Notice of Intent to Construct grants right of entry to the Local Health Department and the State to the referenced property. ISSUANCE OF BUILDING PERMIT: Once the LHD deems that the Notice of Intent to Construct is complete via signature in the section below,the owner may apply to the local permitting agency for a permit for electrical,plumbing,heating,air conditioning or other construction,location,or relocation activity under any provision of general or special law pursuant to G.S.130A-338. DHHS/ENS/OSWP—AOWE COMMON FORM Updated April 2022 Page 3 of 6 AOWE Common Form LHD Reference: This section for Local Health Department use only. PART 2: LHD Completeness Review of the Notice of Intent to Construct "(c) Completeness Review for Notice of Intent to Construct.—The local health department shall determine whether the notice of intent to construct required pursuant to subsection(b)of this section is complete within five business days after receiving the notice of intent to construct.A determination of completeness means that the notice of intent to construct includes all of the required components.If the local health department determines that the notice of intent to construct is incomplete,the local health department shall notify the owner and list the information needed to complete the notice.The owner may then submit additional information to the local health department to cure the deficiencies in the initial notice.The local health department shall make a final determination as to whether the notice of intent to construct is complete within five business days after the department receives the additional information.If the local health department fails to act within any time period set out in this subsection,the owner may treat the failure to act as a determination of completeness. The owner shall be able to apply for the building permit for the project upon the decision of completeness of the notice of intent by the local health department or if the local health department fails to act within the five business day time period." The review for completeness of this Notice of Intent was conducted in accordance with G.S. 130A-336.2(c). This NOI is determined to be: ❑ INCOMPLETE(If box is checked, Information in this section is required.) Based upon review of information submitted in Part 1,the following items are missing: Copies of this form listing missing items were sent to the AOWE and the Owner on Date via with directions to re-submit missing items using Page 5 of this form. Email,FAX,USPS,hand-delivered Print Name of Authorized Agent of the LHD Signature of Authorized Agent of the LHD Date ❑ COMPLETE(If box is checked,information in this section is required.) Based upon review of information submitted in Part 1 of this form,this NOI is deemed COMPLETE. Copies of this signed form were sent to the AOWE and the Owner on via Date Email,FAX,USPS,hand-delivered A copy of this NOI and tracking information was sent to the State on via Date Email,FAX,LISPS,hand-delivered Print Name of Authorized Agent of the LHD Signature of Authorized Agent of the LHD Date DHHS/ENS/OSWP—AOWE COMMON FORM Updated April 2022 Page 4 of 6 AOWE Common Form LHD Reference: Re-submittal of NOI with missing items included This Section is for use by owner to submit items noted as missing during LHD Completeness Review above. Resubmittals must be accompanied by a cover letter from the AOWE. LHD USE ONLY: This NOI resubmittal received: _ by Date initials Item#from initial NOI Resubmittal description Attestation by AOWE certified in North Carolina pursuant to G.S.130A-336.2 I, hereby attest that the information required to be included with Authorized On-Site Wastewater Evaluator(Print Name) this Notice of Intent to Construct is accurate and complete to the best of my knowledge and that the proposed system shall meet applicable federal,State,and local laws, regulations,rules,and ordinances. Signature of Authorized On-Site Wastewater Evaluator Date The section below is for Local Health Department use after submittal of items noted as missing above. LHD Follow-up Completeness Review of Notice of Intent to Construct This follow-up review for completeness of this Notice and Intent was conducted in accordance with G.S. 130A- 336.2(c). This NOI is determined to be: ❑ INCOMPLETE Based upon review of information submitted in the RESUBMITTAL above,this Notice of Intent remains INCOMPETE because the following items from Part 1 of this form remain missing: Copies of this signed form were sent to the AOWE and the Owner on via Date Email,FAX,USPS,Hand-delivered Print name of authorized Agent of the LHD Signature of authorized Agent of the LHD Date ❑ COMPLETE Based upon review of information submitted in the RESUBMITTAL above in addition to information provided in Part 1 of this form,this NOI is deemed complete. Copies of this signed form were sent to the AOWE and the Owner on via Date Email,FAX,USPS,Hand-delivered A complete copy of this form with tracking information was sent to the State: via Date Email,FAX,USPS,hand-delivered Print name of authorized Agent of the LHD Signature of authorized Agent of the LHD Date DHHS/EHS/OSWP—AOWE COMMON FORM Updated April 2022 Page 5 of 6 AOWE Common Form LHD Reference: PART 3: Authorization to Operate(ATO) Except for date received,the Section below is to be completed by the Owner. LHD USE ONLY: Initial submittal of request for ATO received: by Date initials Date of Post-construction Conference: T The following items are included in this submittal for an Authorization to Operate under an AOWE permit: 1. Signed and sealed copy of the AOWE's report that includes the information in G.S. 130A-336.2(k) ❑ Yes E No 2. Operation and management program ❑ Yes El No 3. Fee (as applicable) ❑ Yes [ No 4. Notarized letter documenting Owner's acceptance of the system from the AOWE ❑ Yes ❑ No 5. On-site Wastewater Contractor name: License number: Mailing address: City: State: Zip: Telephone number: E-mail Address: 6. Proof of Errors and Omissions or other appropriate liability insurance for the On-site Wastewater Contractor is attached and includes the name of the insurer, name of the insured, and the effective dates of coverage. ❑Yes ❑ No Attestation by the Owner for Authorization to Operate I, hereby attest that all items indicated above have been provided to the Print name of Owner County LHD and the system shall meet applicable federal,State,and local laws, regulations,rules,and ordinances. Signature of Owner Date This section for LHD Use Only. LHD Review of required information for the ATO ❑ INCOMPLETE Based upon review of information submitted in the Section above,the following items are missing from the information required for an Authorization to Operate for an AOWE permit: Copies of this signed form were sent to the AOWE and the Owner on via Date Email,FAX,USPS,Hand-delivered Print name of authorized Agent of the LHD Signature of authorized Agent of the LHD Date ❑ COMPLETE Based upon review of information submitted in the Section above,this Authorization to Operate is hereby issued in accordance with G.S. 130A-336.2(m). A copy of this complete NOI/ATO with tracking information was sent to the State on via Date Email,FAX USPS,Hand-delivered Print name of authorized Agent of the LHD Signature of authorized Agent of the LHD Date ISSUANCE OF CERTIFICATE OF OCCUPANCY: Once the LHD determines completeness based upon the ATO submission,the owner may apply to the local permitting agency for permanent electrical service to a residence,place of business or place of public assembly pursuant to G.S.130A-339. DHHS/EHS/OSWP—AOWE COMMON FORM Updated April 2022 Page 6 of 6 �_--....411 AGRITEC-01 GKROHL AC-IC/RCP CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDDIYYYY) `----- 3/14/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Connie Garkalns Hartsfield&Nash Agency,Inc. 919 556-8758 10405 Ligon Mill Rd.,Ste H ( c JL,E:q:(919)556-3698 fac,No):( 1 Wake Forest,NC 27587 ADDREss.Connle@hartsfield-nash.com INSURER(S)AFFORDING COVERAGE NAIC N _ INSURER A:Selective Insurance Company of the Southeast 39926 INSURED INSURER B:ACCIDENT FUND INSURANCE COMPANY OF AMERICA 10166 Agri-Waste Technology Inc INSURER C:Evanston Insurance Company 501 N.Salem St Ste 203 INSURER 0: Apex,NC 27502 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDLISUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER (MMIDO/YYYY) (MM/DDIYYYYI LIMITS A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2,000,000 CLAIMS-MADE X OCCUR S 2253659 1/18/2023 1/18/2024 DAMAGETOREoNcurrence) $ 300,000 MED EXP(Any one person) $ 10'000 PERSONAL&ADV INJURY $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 4,000,000 POLICY I X I JECT LOC PRODUCTS-COMP/OP AGG $ 4,000,000 OTHER: $ A AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT 1,000,000 (Ea accident) $ X ANY AUTO — S 2253659 1/18/2023 1/18/2024 BODILY INJURY(Per person) $ — OWNEDT ONLY AUTOSSULEDpp BODILY INJURY(Per accident) $ AU S ONLY AUOTOS ON Y (Perr a�dentDAMAGE $ S A X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 2,000,000 EXCESS LIAB CLAIMS-MADE S 2253659 1/18/2023 1/18/2024 AGGREGATE $ 2,000,000 DED RETENTION S $ B WORKERS COMPENSATION X S AND EMPLOYERS'LIABILITY STATUTE EH R Y/N 100003072 1/18/2023 1/18/2024 1,000,000 ANY IPROPRIET ER EXR NE R/ECUTIVE N N/A E.L.EACH ACCIDENT $ (Mandatary In NH) E.L.DISEASE-EA EMPLOYEE $ _ 1,000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ C Prof&Pollution MKLV3ENV103400 8/22/2022 8/22/2023 Each Claim 5,000,000 A Leased I Rented S 2253659 1/18/2023 1/18/2024 Equipment 25,000 DESCRIPTION OF OPERATIONS 1 LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE ***This is ONLY For Informational Purposes THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN P ACCORDANCE WITH THE POLICY PROVISIONS. Contact Agency for Specific Holder info to be added **** AUTHORIZED REPRESENTATIVE AU ha.KnO4 ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD 1 AVIIT Engineers and Soil Scientists Agri-Waste Technology, Inc. 501 N Salem Street, Suite 203,Apex, NC 27502 agriwaste.com I 919.859.0669 Soil Suitability for Domestic Sewage Treatment and Disposal Systems Lot 22 Penarth Drive, Catawba, NC. 28609 Cardiff Glyn Subdivision (Catawba County) PREPARED FOR: Adams Homes—AEC, LLC, Client PREPARED BY: Jeff Vaughan, Senior Agronomist & Soil Scientist Trevor Hackney, Environmental Scientist DATE: June 20, 2023 Soil suitability for domestic sewage treatment and disposal systems was evaluated on August 9, 2022, for the proposed property located at Lot 22 Penarth Drive, Catawba,NC. Jeff Vaughan and Trevor Hackney of Agri-Waste Technology, Inc. (AWT) conducted the soil evaluation. This evaluation was done to facilitate permitting for a septic system. This report and attached documents were prepared to meet the requirements for an Authorized On-Site Wastewater Evaluator to meet G.S. 130A-336.2 A drawing of the site plan, septic layout, and boring locations is included in Attachment 1. Profile descriptions for each boring are included in Attachment 2. Additional documentation about the property is included in Attachment 3. This property is a subdivision of a larger property that will make up the Cardiff Glyn subdivision. This property area is approximately .93 acres. The property is a wooded lot. The home is proposed near the front of the property with the septic system proposed upslope of the home. The proposed septic system is a pressure manifold septic system utilizing a 25% reduction product. Soil Suitability for Domestic Sewage Treatment and Disposal Systems The drawing in Attachment 1 details the property boundaries (as proposed by Frank Craig), soil boring locations, and layout of drain field trenches (Completed by AWT). Soil borings were examined to determine soil suitability for on-site sewage disposal systems in accordance with 15A 18A .1900 Rules for Sewage Treatment and Disposal Systems. These borings were advanced with a hand auger. 1 A septic layout was performed to demonstrate available space (.1945). The layout in Attachment 1 indicates there is available space for a three-bedroom pressure manifold septic system utilizing a 25%reduction product. The proposed LTAR (Long Term Acceptance Rate) by AWT is 0.3 GPD/ft2. The soils on this property are group IV soils within the distribution and treatment zone as used to define the LTAR. Since usable slope corrected soil depths meet or exceed 30" AWT is recommending the use of the 25% reduction product. The maximum trench bottom should not exceed 18". With an LTAR of 0.3 GPD/ft2, 600 linear feet of trench are necessary to support a three-bedroom home initial and repair system. The attached drawing proves that 306 linear feet of trench can be installed for the primary septic system. The attached drawing proves that 302 linear feet of trench can be installed for the repair system. Any disturbances or grading done in the usable area or within the proposed setbacks will change the potential of using the area designated for a drain field. We appreciate the opportunity to assist you in this matter. Please contact us with any questions, concerns, or comments. Sincerely, Jeff Vaughan, AOWE ,t0 Attachment 1: Site Plan/Drawing and Calculations " g- fff $ n y L L ji qii C= s O C 1[►/J�? rlit il 3 minkro > °, m 13 a) Iec i 8 041r 3 co 9. a) CO >, c c U) .. } N RS a) F- a) J a) p co a) o n3 > > fl Q '� O U U Q_ U EL CC O W\ x —Y`\ / W ) .�. -o C }' r N ch In (O N - --- - - - L U) WWU) WUnUnU 0) N N N c co O o CO p p a) O U N a E I Jh CDw IL U O Cn W c L �O 7 N c (r0 u) a) (Ni co J 0-) E co 0 (/) O a) c) c LO Q (I) N c z O om E c`a z -A ca 2 (9 (D aa)) N o ' m a) o E N ° (a (a CO I a� ti r` w U (c)) (Cl CO a� .� c0 7 CO c0 (a u O V' co N co r (D 4 (� a) -o a •4 z N 6) 6) o) N an d p (U c6 z a - O 4 o a) r O r o) c) 0- r r c L L I Li-) U U 0- < co U r SD —) rn CL rn Q io < rn rn cn F- U 3 z > _c—� 0 c a) O '� 7 LL U c c > a 0 0 Cl)a) ate) aa) ' C.) 0- d 0_ U) ill aJ I iiT (V I !' Iii > yy 0 •5 c � Euu OjAt 2 �:. / / l / / / `l `� 9,•9E,8ti,91S I. ' S �' a�'ot I. • 1 co) 096. Ci II ..__,, 1 / 996 1 /1/ 8S6 \ up cmnl) 956 m 1 „,../ c J �1 it gge t - � ii;;\ , �a2/: 94 J ,y �� e�� i' ti s ti F 1L 1 , )ioegle6 edo1sutiw0 SE \ I6 II Q7 o 1 )P •"cf CO /0447 jI 9b6 s 1 N (HOUSE BOXO 60'x60' j t'2 fits \ • \ \,5/4%. iii�iia/a7V//ii ) —24.s ' Hoeglec 94303. .L I. ....,/ N 1 _l .6.4 N C.• s E T M1 tt '',?! N /Ill - ff m 3 �• d w C a ,. - j des 03 9' W.d g M,60,LE,811� i 2(6c g _ ; N 0b6 i-- o . n o c , c $ ��- �II 4, �/11ap C �" " 8WC w . „...........„,...-------\\ q nni� anen c d. Ti \._—�� d 1 O9 O CO N W"�O a J 5 ,_ w >, Si gg r , �� �� C m 'fici r a `� a' ° I a 1 , i i = .Sprig ,lic,,k pg,AAU F5 Kt / /I! / If 0 ju_ / / U'' / I; I 0 �/ LLLL COCO LLL LLL' H L ( ) ^^ cL LLLL LL L I Y L.L �( WM — 0 w moo o co � t C 0 - E 0 E Y U U o 0o vm= g c ° oz0 > > ' ^y o y.2 y ° c N pi[—m m o O O d d _ c ° o u ca 0 ° Vo crvacoo .c v c ° c ;E > v-y c a o a m ° n m L t -c O N d L O p d ° V o o j ••� r V y c _'p d O. Un (n 7, - ' N . _N U y 4123 a 0 O o ° C 0 ° u! - yv' U= a O L ° 9 g _ o=y 'y 13NNa) a C lC f0U JEjh !JOijI ! I;0; !Igflil W E ��° r- oN �,ia cv630-c I JCr c o• LL) W C ,y a Y Y V).o .' E o oa.c^ J a U gcm! IIil c o U)�co o a�0 C) LL 0d U LL (A�F- coI- � ry n'i ri UU W W LLa. 0.U)U)U) & ,_ gy a C- ill EYS £ilht O gE y q 1 g E -13 Ar '• / N co _ f CO U p— 7 O a N C % J>. 1a0 ( I ' �` a i / I % I \ A c Q O O O p `� \� 7/ / I• II t E O O O a •�. -.-.-._- ._.-.-i /• i � i 1 / ^7/ u / ea•/ %. �A t/ / E v�v v 4 '� �dy/. n vi n r t-i of ` �.i' �./ 3�g% /' / �f a \ ...--• .1.„,... ...--- 0. 63 5 1 ___. /' J. U AAA \ r P" - _.—� ''` N-0 )*8a(esedo(suMoa.9z — -- t - o O o — 8 / / • U c r t7 y 0. = J v J 2i,_1 __ \ 1 II 5 •••i• \ 1 a ` 3 co o o a ar t9.1 0 i a § \,,L, HOUSE BOX% N{ �,z §. J 60'x60' % I a a i1 i U a m 5 0 m 100 E .0 • °' 0 t o --4c y_ w O U i ;0 d D 0 ..w V _d O,p W 0 0 O O U 07 U O d-.5 O U 1.7„ O 0 U 0 C C'O d C 7 O- (n O 0= 15, o o E c o c o> o d `m s`co-" c °0-- z N o n I� c ..., m ,-.0 ° O d_ U E m-.`. 0'- 01-E d 'o N -a J T7 11111 - m wN - mOO N O , . yVIC � cayLc HOo - oy .00 0a7 � cE > a m Q.2 •O C .0 Es• '0.o z 0! T y aE o v_i- o m0dN W nc O mj 0 > U y=.m m E C d cm u7 w C C C 1 Q1- - w o " o•o 0 m c >,m `m 0 c E c.4 - E O> m o-0 r J .�.5 .� v ui c o::- M t..7. o 43 v v L,u o c TL °.u n,o a O- o m o E :"'o,: c`a m y y d - o ac m4=- m•c$ o Om > m3 �O � iiiin o E L E 0 E E =L S o'c:: u c m a , 0- o u -0 o y -UV.CO7 0 O+no0-0E+7-•C..+ECo . H0oQ0•.O-._.. ..L.�V1 E0 I I i I i ` 1 1 I a • N M •d• u] r- I I I 1 1 i . 1 ' s I lh 1F4 Iii 1 r. CC i To a tigg ti,3, Er) 5 ..Sgiig -- 1 LI C— M— 1(11/4 1 / 1 o— j D. m M CO• CO 4 `�\ �C Q O O O O / J ; / 1\�O J m mm s. 0 0 0 ¢ m% /'� �/� / /EWR - 8 /a NTN J / pp LL o, r < /f '/I \\ Ct/ / a 6 6 6 \.\ \ / t n rn �._._ _- / /..../ G = _ . / I a E . )._\ __._._ a0 N / / / G ' / _01j _� 1 / .� i// ,G / .-- / .0 i ..,. \ --. -- ..-- In' Ea a / / 9 / ram` c s etTy _ \ � � �Iae91aSL odgsumoa,gZ —— fL6 LL o // / CZz � 1 ( 1- W N n)O a, J a m I V///////////////////////////////////A I 0 a O v E o 12 • 'ac 'o y13 L ° U f8 O UD a o .v o ° ° p c Ca t=v2 c oT - C 2 0° rn q_ 2 , 0 v c�•n o o D m v x N o a �c ..J ° m ,'�° D aN8E No : ms-ac v �� o � Z`` ,z, yea (, 'D- — Vi N a w N VI O C N ° 0 f4 f0 N c g 0 7.N N 3 E N E. 2062il 0 L y °O — °° C E -° N N 2 U ° zI1I!!1 _ E C d L i °.C: Liih N.0— 0) •O O V.° j a°... p y >,° 7 O ° Q Ll. d U) iI I c I I d I i 1 • 1 4 5 i J A � Il _ i_ pi Q •5 C vs J 131 2 1 1. 'i 1: as v o w ui a> # c C O U O uC dw ° a, ° L O ° N C a ° N C#a D N N o p Cp i 99 N# `.c+ p O O N in C 2 V Fla 0_, . U'V V N N O Y O N a Q a o as N m > c u 1.2 LL ] S m a o m °C « ` °, > o au• ma o 0 0 0 oy v c u E N °� a 32 O�C77 Fp O C ry oN a ..,c p c ozN a o 8 �_ - °L cav oc E C O C p 3.. mA - oN ° °°o mx ° oN— aa> Co E E p 'a j o a w sibbQg E o 7 vC.r O O0 D o7 y C °° { s e = w do F ° :, " ° C E " a ' Ev > w Ea Nc 'o Y a t 4m o E l® §iii;g0IO O o o .n• o °tt E .00 ym1,u m o»- uoc °+ « i ihill9gg6igg o zEN ° ma ° o-c oo N v CO NC a ° p o ✓+ m aE N o c ° « O c n 7 L ` O, C ° p W 0 G r C ^ « y .0 N 3. C a UmO0— O N O O C— O p p 2 H O 1p ..... a O L- J N y C L°� Y U n O+Y a M a1- as c�#N ao0 zr-'c ° moE - vs.8 - O his...,===1,0 —,ae war ; (y M , xi Lei N a0 Oi sg G �' Tir. �. N al i Q a L C a` N ... w a T 2 O .O• I Y a C = N L�Y O c E a ' � _ fC N O ° cc iii ° g aE UOa a a N > N al wd D3 c oi ' 7 y 0 o a a> a °, a a 02 c _ O NO W ug pc E. D p 13 U C 3, C OC g N ` ° o O N 0 02 a • o v Io mya E PC, 0 cet S 0 c u a ° C 2 ° ° _ °' E E o E w a o d EZgyO _ o , E v o P Y t On Ii 2 o 2 • Uq 8N ' a a ° Cy « > co o y om o 0 o Q c N 3 O O O aLL f en NC O y G ▪ L .0 0 — C C # O C o ° � ° (11 c U p, c c .- > E 1-4 c- a y� u # L O ° y p N °eh O y t6 @'� 1 C O'a .- a C« CO a`'C N Pp _ e. cC 11 g §$ a$wv°a 9i ._ ... o. e. Ec 00 sn 8.9 tiro E°u '- aw a >o �a, 6s� q n Q■o FS� iL t, pa a g13 5k i 'v€i3 �i 3118 N „y lO 1� 00 °, ci �, Q11 w pp g -a!i S3e.1 l 1 1 :3 {"5. tg n 1:2 P yI �ggggg-`ggtl �yy.3 gg 9• �� f. E� S3$ a "3 ida�'.. iii SSlMgl` d �k a aE s 1! ggz i=ab 3 •� € 5 a. ! gE{{p3 Ea, �t. gs i{{g{` s{Egg _ N Id1311a{t .111 1%1 illfilffiiifggii e 4 !I a 5 1, ' $w !� '� w g g i __ MI N N M� I • b r MI . I 15 al AN I f a i .as o ? Y W sFg ! ! \`�Ir a� - itl a 24 N @j I d$ Will i. y . �£ c . I 'll <J Y cWIt O c = wig 14/ )1/ /3 in }ffili CC i t' 8 '1'g 1 I b G " F vy ~a~ Y G It Q� 6NF'1J ftO(•$($��• W2N ipU' f Z 41 I E re `a 's 1W- aotilt PpK C Um U 0. " K €.c. i t` o,� C SO �vVi F53a 'E a° co 8 $ 7cc r"J-Toll-E (� rcz Do g s •o• )( uno I�-,I�rr 7.7%,a1 I pCnL0 (, 2000I'\\l'\ 4U . 2s.. 4 L ¢I¢ WZZd ,��,� JWSlt]. O yV.' Uy 0p61(Om I§ ia,T-Q1� o ' K ye' Oj S222 u3 oos$ ^ 4�. dKK Kl OO -5U Fo"St L 04B1W. U M 9 l In Vf u y L ,1 r 0. ii_iiB iii n�lr i Z li i ;':, ! m 1 II `I .A.4, m.. r ..!I YY t 411 CO 1.i. a s i 5 ,' 11 4 Si d # a +. 4 I _ Q tz,.'. I I, 7 , 111 MI1 0 0 .45 .,.. a=I s� I 1 m O i • f I IIII 1 LL , i1 i ;Idl II�u J ;; :. .&,,, ' ��U' ',..�.. It Y T J- Ig g !of =_ O lt i _ !al 'i. / ..li :, :i ;1, !f 3 A 'III § 1 e 2 R cA It ' 1 J '!r' 5d. 'Iddddd I . � 0 I 0 1 h°I1�°nlr°wYr°t 1Y11 '�I E . 2 o �� =71 I , ;i, w II 1 Cl) .1 I 11 II Ir 1 Iii l 111 " 11'11 � a � � 9g W I 111 � htjl; C` BE 111!Ili aE 3 A Eli 5a a px D��a'"'1ti I ::: 2 Ni -1 5II ila 6aag1€1fi 1 E I it' g81 13i3 , 3 o e!r! Iak�ki- 4 31E3t lliiir .k a °I t to i 1 aFCp{5s 4 � p3aay2S9 Ey3ee � S$8 a ,r'��4 <2Y,aB=4A $5 s m A S f a �. Fl AR 4 iitailliWIlltilgil! is 5 _ 2 L C c t�5 AA p l E _3 3� Y°�g. i L39 Y 1 5, ;s$7YY 2'g�p iHh t; YE ill 3 Ii6 1 A 3 1 ° ti F p`�° e $ h' j is M a` ill` ;aqe ;il �- e� 5a tl ph i lip - �L a`k P 1 iss il 3 IIIJHII IIIiSB7 ab 55 ; e$ 3+,lin 11 f €r It Q Yob�ai . 2i Iii H11i E e 1 6i k3 eYg ii Di1IIIit 9 — hltilililflull R $ Hi � 1. 5 3 p; 35 1 R 111 ,4 sill Illtiil gliaiiii111 f l t 1 z 73 gg i F H s L 3 3 Ii Me 3p s yf a d I .9 i " 72 Iil ll I3 OM a as' ! 1 /- "� s e l A r% ce 7� g g� 16 A e a E a S d °aii 21 2S a a ! 3 ;1 , , 1 ►4 c, r 4��,q X 3 ti e A �. 1 x ` 14V gqg aap ; -3 i i h 5, is s ig 43 ► 4 i11 J `� la a llilti g Paf ?[jllujji:: Ialt s t k kr @E@llF•• a ; s yg1a �9 . 2.Z $ e�aEe i :' J1I{I ik �� E df a- E F k3 $ �{ 8 R J ; - �, ^�,. .J i;d Q liii!! i'1:' S ' 81:1 ' i At a :e 1 9 x? R � � U a al�.3 A3AA E j[r3 Eiq xWW1 33j yp Eppp lag II r ..fda^4 r j F P3 Sa g 5 $ a ; J +� !'!I I p a '1,- 4 tiiili!IitiiIQ t f ➢fix' HI s" fill 0 III gggg H ass Eq $4i1 H ill 1 lap i i. qqt . 10 11 Iii & k IP �13 �� �g � E SE* R i il - sit a.6I�n7£ n �,Ey£g�. 3 g g §`8 iA i to Q xaJIIU a� ti E11 $ a $ 1 u i alc IllI il' tEl ° 15; 1Faia 1 {5ay)1)yy! 0l y Rgi hi 0g lgp $gd BAs pi] ,it ii c h3 p� 0;mteiJill. S e a s xY Septic System Design - Summary Page Project: Cardiff Glyn-Lot 22 Date: 5/5/2023 Property: 5064 Throneburg Rd V Catawba, NC 28609 County: Catawba Engineers and Soil Scientists Subdiv.: Cardiff Glyn Agri-Waste Technology,Inc. Lot#: 22 Permit#: Project Manager: Owner: Adams Homes-AEC, LLC Jeff Vaughan, PhD, LSS Address: 3401 St.Vardell Lane, Suite B Type of System: III bg jvaughan@agriwaste.com Charlotte, NC 28217 919-859-0669 Phone: 704-558-4527 Engineer: Email: bcashion@adamshomes.com PIN: 378003016801 Rodney L. Huffman, PhD, PE rhuffman@agriwaste.com EHS: Soil Parameters Soil Evaluation By: Special Conditions/Notes: LTAR: 0.30 gpd/ft2 Design Parameters Type of Establishment: Residence,5 or fewer bedrooms Unit: Bedroom #of Units: 3 Septic Tank Specifications Min.Tank Capacity: 900 gal Exterior Interior Actual Tank Volume: 1,250 gal Length: 125.5 119.5 in. Tank Manufacturer: Shoaf Width: 65.5 59.5 in. Tank Model: TS 1250 STB Depth: 61.5 54.5 in. Primary Draintield Specifications Type of Distribution: Parallel Pressure Manifold Trench Bottom Area: 1200 ft2 Trench Media: Chambers Minimum Drain Line: 300 ft Trench Width: 3 ft Actual Drain Line: 306 ft Trench Depth: in. Number of Lines: 3 (or as specified on permit) Minimum Line Spacing: 9 ft O.C. Wastewater Treatment System Design Calculations Project: Cardiff Glyn - Lot 22 Location: 5064 Throneburg Rd Catawba, NC 28609 County: Catawba Septic Tank Sizing ._. :aauremmsiewYi�siwxul�'ni Yeuum'i.+rwaEenen Daily Flow Estimate: Unit #of Units Flow/Unit Flow/Day Bedroom 3 120 360 Q= 360 gpd Septic Tank Minimum Capacity: Per NCAC T15A:18A .1952(b)(1): For individual residences with 3 or fewer bedrooms, Minimum Liquid Capacity (V)= 900 gal Septic Tank Specs: Manufacturer: Shoaf Model:L TS 1250 STB Volume: 1,250 gal Weight: 11,000 lbs Exterior Interior Length: 125.5 119.5 in. Width: 65.5 59.5 in. Depth: 61.5 54.5 in. Shape of Risers: Circular Diameter: 2.00 ft • Pump Tank Storage & Float Settings Project: Cardiff Glyn - Lot 22 Location: 5064 Throneburg Rd Catawba, NC 28609 County: Catawba Tank Manufacturer Shoaf Tank Model f TS 1275 PT Interior Height(in.) 60.5 in. Avg. Storage 21.07 gal/in. Primary System Elevations, measured from bottom towards top(0 = Interior Bottom of Tank): Top of pump (including 4" block) 16.1 in. (Pump height= 12 1/8") Pump Off 18.0 in. Pump On 24.5 in. (set for dose volume) Alarm On 30.5 in. (6 in. above On Float) Emergency Storage Available Pump Tank 632 gal Days of Storage 1.76 days (determined from"interior top of tank"-"High Water Alarm") Repair System Elevations, measured from bottom towards top (0= Interior Bottom of Tank): Top of pump (including 4" block) 16.4 in. (Pump height = 12 13/32") Pump Off 18.5 in. Pump On 25.0 in. (set for dose volume) Alarm On 31.0 in. (6 in. above On Float) Emergency Storage Available Pump Tank 622 gal Days of Storage 1.73 days (determined from"interior top of tank"-"High Water Alarm") ELEVATIONS Project: Cardiff Glyn-Lot 22 Location: 5064 Throneburg Rd Catawba,NC 28609 County: Catawba Benchmark IP SW corner Lot 22 BM Elev 941.1 ft Septic Tank 1,250 gal Ground Surface 40 ft Depth of Soil Cover 12 in. 1.00 ft Overall Ht of Tank 61.5 in. 5.13 ft Elev,Base of Tank 937.58 ft Ht to 4"Inlet Invert 50 in. 4.17 ft Elev,4"Inlet Invert 941.74 ft Ht to 4"Outlet Invert 48 in. 4.00 ft Elev,4"Outlet Invert 941.58 ft Gravel Base 6 in. 0.50 ft Elev,Bot of Excavation 937.08 ft Pump Tank 1287 gal __ Ground Surface [__943.5Ift Depth of Soil Cover 14 in. 1.17 ft Overall Ht of Tank 67.5 in. 5.63 ft Elev,Base of Tank 936.71 ft Ht to 4"Inlet Invert 57 in. 4.75 ft Elev,4"Inlet Invert 941.46 ft Ht to 2"Outlet Invert 58 in. 4.83 ft Elev,2"Outlet Invert 941.54 ft Gravel Base 6 in. 0.50 ft Elev,Bot of Excavation 936.21 ft ST Inlet Pipe Grade @ Stub-out - 944.8 ft Depth of Stub-out,top 1.5 ft Elev,Stub-out Invert - 942.95 ft Elev @ ST Inlet Invert 941.74 ft Length 10 ft Slope 12.0 Pipe,ST to PT ID 4 in. 0.33 ft OD 4.5 in. 0.38 ft Elev,ST Outlet Invert 941.58 ft Elev,PT Inlet Invert 941.46 ft Length 11.2I ft Slope 1.0 % Cover over inlet pipe 1.60 ft Pump Reqmt. Floor Thickness 4 in. 0.33 ft Elev,Pump Tank Floor 937.04 ft Pump Block Ht.1 -711.in. 0.33 ft Elev,Pump Intake 937.38 ft Grade @ Primary Manifold 956.E ft F-95-8-.1 Grade @ Repair Manifold ft Min.Cover '14j3 in. 1.50 ft Max Elev,Primary 954.60 ft Max Elev,Repair 956.60 ft Elev Diff,Primary 17.22 ft Elev Diff,Repair 19.22 ft • Drainfield Design Project Cardiff Glyn-Lot 22 Location 5064 Throneburg Rd Catawba,NC 28609 County Catawba Drainfield Sizing Primary LIAR 0.3 gpd/ft2 Daily Design Flow 360 gpd Type of Drainfield Media Chambers Req.Drainfield Area 1,200 ft2 Required Drainline Trench Width,Eff. 3 ft After 25%Reduction 300 ft Required Drainline 400 ft Minimum Line Spacing 9 ft(O.C.) Repair LIAR 0.3 gpd/ft2 Daily Design Flow 360 gpd Type of Drainfield Media Chambers Req.Drainfield Area 1,200 ft2 Required Drainline Trench Width,Eff. 3 ft After 25%Reduction 300 ft Required Drainline 400 ft Minimum Line Spacing 9 ft(O.C.) Drainfield Layout Elevation Line Length Used as Used as Line Use Flag Color (ft) (ft) Pc unary(ft) Repair(ft) 1 Layout Line purple 952.3 25 2 Layout Line white 953.3 68 66.0 3 Layout Line yelllow 954.2 113 102.0 4 Layout Line red 955.0 118 102.0 5 Layout Line blue 955.7 127 102.0 6 Layout Line purple 956.7 191 150.0 7 Layout Line white 957.4 105 86.0 Total 747 306 302 Count 7 3 3 Note:Line length totals are shown to the nearest foot. For Chambers or Low-profile Chambers: Effective trench lengths are shown.Add 1'for total installation length. PRESSURE MANIFOLD DESIGN (Primary) Site information Project: Cardiff Glyn-Lot 22 Location: 5064 Throneburg Rd Catawba,NC 28609 County: Catawba Design Information Estimated Daily Flow 360 gal/day L.T.A.R.(from Catawba Co.) 0.3 gal/day/ft2 L.T.A.R.+5% 0.315 gal/day/ft2 Trench Width 3 ft. Line Length Required 400 ft. Length after 25%Reduction 300 ft L.T.A.R.Reduced 0.400 gal/day/ft2 L.T.A.R.Reduced+5% 0.420 gal/day/ft2 DRAINFIELD INFO.- Primary Proposed Type of System/Distribution:I Pump to Pressure Manifold using Chambers Flag Line Flow Flow/Foot Line Line No. Color Length(ft) ; Tap (gprn) (gpm/ft) L.T.A.R. 3 yelllow 102 1/2in SCH 80 5.48 0.054 0.392 4 red 102 1/2in SCH 80 5.48 0.054 0.392 5 blue 102 1/2in SCH 80 5.48 0.054 0.392 Total 306 Total 16.44 Avg.i 0.39 Note:Line lengths are calculated in 4'increments to reflect use of Chambers product.2'added for endcaps. Total Run Time 21.90 min. Drainfield Capacity 199.8 gal %of Drainfield CapL'hrtr( � 1 : 'thd`000f.). (Req.Range 66-75%) Dose Volume 136.9 gal/dose Run Time/Dose 8.3 minutes Range 5-7 minutes unless uphill,checked Volume/depth 21.07 gal/in. (Per tank manufacturer's specifications) Estimated Drawdown 6.50 in. Manifold Box Number of Taps 3 with 0 Split(s) Manifold Length 3.0 ft. (approximate) PRESSURE MANIFOLD SYSTEM DESIGN (Repair) Site Information Project: Cardiff Glyn-Lot 22 Location. 5064 Throneburg Rd Catawba,NC 28609 County: Catawba Design Information Estimated Daily Flow 360 gal/day L.T.A.R.(from Catawba Co.) 0,3 gal/day/ft2 L.T.A.R.+5% 0.315 gal/day/ft2 Trench Width 3 ft. Line Length Required 400 ft. Length after 25%Reduction 300 ft L.T.A.R.Reduced 0.400 gal/day/ft2 L.T.A.R.Reduced+5% 0.420 gal/day/ft2 DRAINFIELD INFO.- Repair _ Proposed Type of System/Distribution: Pump to Pressure Manifold using Chambers Flag i Line Flow Flow/Foot Line Line No. Color 1 Length(ft.) (gpm) (gpm/ft) L.T.A.R. 2 white 66 1/2in SCH 80 5.48 0.0831 0.397 6 purple 150 3/4in SCH 40 12.50 _ 0.083 0.399 7 white 86 1/2in SCH 40 7.11 0.0831 0.395 Total 302 Total 25.09 Avg.J 0.40 Note:Line lengths are calculated in 4'increments to reflect use of Chambers product.2'added for endcaps. Total Run Time 14.35 min. Drainfield Capacity 197.2 gal %of Drainfield Cap 69.5% (Req.Range 66-75%) Dose Volume 137.1 gal/dose Run Time/Dose 5.5 minutes Range 5-7 minutes unless uphill,checked Volume/depth 21.07 gal/in. (Per tank manufacturer's specifications) Estimated Drawdown 6.50 in. Manifold Box Number of Taps 3 with ' 0 Split(s) Manifold Length 3.0 ft. (approximate) • PUMP DESIGN System(initial/repair): Primary Project: Cardiff Glyn-Lot 22 Location: 5064 Throneburg Rd Catawba,NC 28609 County: Catawba Friction Losses Suction Head L OJft (submersible 0) Elev.Difference(highest point from pump) 17.22 ft Design Pressure At Outlet L 2 ft Supply Line-1.5"Schedule 40 PVC_ Pipe Diameter,NominalL Pipe Diameter(ID) 1.59 in. Flow 16.44 gpm Pipe Length[____, 223 ft Velocity 2.66 ft/sec Pipe Length for Fittings 22.3 ft Meets requirement that 2 ft/s<v<5 ft/s. Equivalent Length 245.3 ft Estimated Friction Loss in Supply Line 4.50 ft Pressure Filter Friction Loss 0.23 ft (from manufacturer) Friction Loss-Taps/Special Fittings 3.5 ft TOTAL 27.45 ft. Flow for Anti-Siphon Hole Hole Diameter' 3/161 i n. Hole Flowrate 2.17 gpm Pump Efficiency 0.7(assumed,typical) Motor Efficiency 0.9 (assumed for electric pumps) Flow 18.61 gpm Required Horsepower 0.20 hp TDH 27.45 ft Pump Selection Manufacturer Zoeller _ Model: N152 Horsepower: 0.4 PUMP PERFORMANCE CURVE MODEL 151/152/153 so u- 45 163 12- 40 NNN 35 52 10- 152 30 • Operating S- 26 151 Point 6 6- 20 75 4- to 2- 5 10 zo 30 40 50 e0 70 60 00 100 GALLONS LITERS 0 b 80 120 100 200 240 z00 300 300 FLOW PER MINUTE mane PUMP DESIGN System(initial/repair): Repair Project: Cardiff Glyn-Lot 22 Location: 5064 Throneburg Rd Catawba,NC 28609 County: Catawba Friction Losses Suction HeadL Aft (submersible 0) Elev.Difference(highest point from pump) 19.22 ft Design Pressure At Outlet I 2 ft Supply Line-1.5"Schedule 40 PVC Pipe Diameter.Nominal I 1.5Iin, Pipe Diameter(ID) 1.59 in. Flow 25.09 gpm 2.8 Pipe Length 27 ft Velocity 4.05 ft/s Pipe Length for Fittings 27.28 ft Meets requirement that 2 ft/s<v<5 fUs. Equivalent Length 300.08 ft Estimated Friction Loss in Supply Line I2.04 ft Pressure Filter Friction Loss 023 ft (from manufacturer) Friction Loss-Taps/Special Fittings` 3.5 ft TOTAL 37.00 ft Flow for Anti-Siphon Hole Hole Diameter' 3/16Iin. Hole Flawrate 2.52 gpm Pump Efficiency`_ _0.7(assumed,typical) Motor Efficiency 0.9(assumed for electric pumps) Flow 27.61 gpm Required Horsepower 0.41 hp TDH 37.00 ft. Pump Selection Manufacturer: Zoeller Model:_ _N140 Horsepower: 1 II C PUMP PERFORMANCE CI._AVE MODEL 140/4140/145/4145 zz, n m- es m- w ro- • Operating Pain[ s- \\\ 0- ]0 u 4- ta a uo NE a110 /0 m b b 50 b M Aa 60 6YLOYS mom o ao leo aro 30 FLOW PER MINUTE 1 Attachment 2: Soil Boring Description Sheets I • COUNTY:Catawba Co._ SOIL/SITE EVALUATION for ON-SITE WASTEWATER SYSTEM (Complete all fields in full) CLIENT: Adams Homes APPLICATION DATE ADDRESS: Lot 22 Penarth Drive.Catawba,NC 28609 DATE EVALUATED: 08/09/22 PROPOSED FACILITY: Single Family Residence PROPOSED DESIGN FLOW(.1949): 360 GPD PROPERTY SIZE: .93 ac. LOCATION OF SITE:Lot 22 Penarth Drive.Catawba,NC 28609 PROPERTY RECORDED: WATER SUPPLY: ❑Private (Public ❑ Well El Spring ❑Other EVALUATION METHOD: X Auger Boring ❑Pit ❑Cut TYPE OF WASTEWATER: %Sewage 0 Industrial Process ❑Mixed • . • • P o SOIL MORPHOLOGY OTHER F (.1941) PROFILE FACTORS 1 .1940 LANDSCAPE HORIZON - POSITION/ DEPTH PROFILE ii SLOPE% (1N.) .1942 1941 .1941 SOIL .1943 .1956 .1944 CLASS STRUCTURE/ CONSISTENCE/ WETNESS/ SOIL SAPR RESTR <AR TEXTURE MINERALOGY COLOR DEPTH 0 HORIZ CLASS 0-10" SCL;GR SS;SP;FR 36" - - Provisionally 8% Suitable 10-36" C;SBK SS;SP;Fl SB 0.3 1 • 0-8" SCL;GR SS;SP;FR - ; - SAP 8% Provisionally SB 8-33" C;SBK SS;SP;Fl Suitable 2 33"+ CL;MA SS;SP;FR 0.3 0-10" SCL;OR SS;SP;FR 36" SAP Provisionally 8% Suitable SB 10-36" C;SBK SS;SP;Fl 3 - 0.3 SB 9a/o 0-10" SCL;GR SS;SP;FR - 36" - SAP Provisionally 4 10-36" Suitable C;SBK SS;SP;Fl 0.3 DESCRIPTION INITIAL SYSTEM REPAIR SYSTEM OTHER FACTORS(.1946): SITE CLASSIFICATION(.1948): Available Space(.1945) Provisionally Provisionally Suitable Suitable EVALUATED BY: Jeff Vaughan Conventional 25% Conventional 25% OTHER(S)PRESENT: Trevor Hackney System Type(s) Reduction Reduction Pressure Manifold Pressure Manifold Site LTAR 0.3 GPD/Ft2 0.3 GPD/Ft2 COMMENTS Updated February 2014 1 LEGEND use the following standard abbreviations SOIL CONVENTIONAL LPP MINERALOGY/ LANDSCAPE POSITION GROUP TEXTURE .1955 LTAR* .1957 LTAR* CONSISTENCE STRUCTURE CC(Concave Slope) I S(Sand) 1.2-0.8 0.6-0.4 SEXP(Slightly Expansive) G(Single Grain) CV(Convex Slope) LS(Loamy Sand) EXP(Expansive) M(Massive) D(Drainage Way) CR(Crumb) DS(Debris Slump) If SL(Sandy Loam) 0.8-0.6 0.4-0.3 GR(Granular) FP(Flood Plain) L(Loam) SBK(Subangular Blocky) FS(Foot Slope) ABK(Angular Blocky) H(Head Slope) 111 Si(Silt) 0.6-0.3 0.3-0.15 PL(Platy) L(Linear Slope) SiCL(Silty Clay Loam) PR(Prismatic) N(Nose Slope) CL(Clay Loam) R(Ridge) SCL(Sandy Clay Loam) MOIST WET S(Shoulder Slope) SiL(Silt Loam) T(Terrace) VFR(Very Friable) NS(Non-sticky) 1 V SC(Sandy Clay) 0.4-0.1 0.2-0.05 FR(Friable) SS(Slightly Sticky) SiC(Silty Clay) FI(Firm) S(Sticky) C(Clay) VFI(Very Firm v.Very Sticky) VS(Very Sticky) 0(Organic) None None EFI(Extremely Firm) NP(Non-plastic) SP(Slightly Plastic) *Adjust LTAR due to depth,consistence,structure,soil wetness,landscape,position,wastewater flow and quality. P(Plastic) NOTES VP(Very Plastic) HORIZON DEPTH In inches below natural soil surface DEPTH OF FILL In inches from land surface RESTRICTIVE HORIZON Thickness and depth from land surface SAPROLITE S(suitable)or U(unsuitable) SOIL WETNESS Inches from land surface to free water or inches from land surface to soil colors with chroma 2 or less-record Munsell color chip designation CLASSIFICATION S(Suitable),PS(Provisionally Suitable),or U(Unsuitable) Evaluation of saprolite shall be by pits. Long-tenn Acceptance Rate(LTAR):gal/day/ft2 Show roffle locations and other site features(dimensions,reference or benchmark,and North. � . ' � 1 _.._.__ L- _�__ i 1 1- 1_.--1 - - �_ i f , i ri f 1 I _[ _t_ 11,_.14 1 1 i 1 ,. I 1 ' i i F IT - - - _.__.. t , -- 7 1 I i I I I I I I I I I COMMENTS: Updated February 2014 1 Attachment 3: Additional Documentation III el l N 3N `A1Nn03 tlBMVln3 a ,; „ 1 A` - (coo i#as) as TimsAnaanw • u (osa4#as) as aana3NOHHi � ,.. Noisiniaens NA1O ddlaanO NVId 3115 llv1i3A0 1 4Y gg III i 4 Y c 3 O E [ pEa$likl . �� J acggJIjJ , P3g"g4- z s 35a13 . le . 1x e - .g v`a ) i s e i i5 ' ig �x,ligi iIii 5 . 9 6 "s dg 1 ' /- ad $e° a rill! € aI j5 i i;ii!l, $ cg i li; II 11 e e it i C ! is le 1! '� .0 F g / $ 3 c +``++1 Z A F. 3 a $ olg c la !. it l/ it qg 1 Pi y m Iw a . 1111111 b3Ett n . . d .I.I .. ., s ! ., '.Q m 1N WV. y. 4r ! Ir S sd e9 a $ PI Zg i '-, illr ..--' o l P 'rnnrr -Wing § 3 -. Ir '„ ��°i - -�._^___ _ n, ! PPPY . ii 9 op rA ,I ». ,� ` _.. L--L uta A3 i z�:�. +` ® 1 Ay i / -1Ir----_, ,------ -,.....-:,._...---,,,,i,,,,,..„�' xr. 3 i Ay \' +�`' I. ®, c \ kt ! ,•1 3 Jr �'giiri'^ = �n �`�I A a,.;. N! i® `i'�"�"C w i�4�y�' i ® yl'�Ry��k.�' y" Jle�ai�r`l•r- Ir .•~ _f . L- FIfF.- ;j>' J '. 1 q j%. f,® 14.(Ije A ,J% ,I,Yvlyh e. a J•\ ; '->94."`.!'iPY�.',u: 1 v'S - __- JI`_ YI ; f$ gay 4r, t,,�(rt('PO1ya /.' /i'__ I :;• •.,. 1r,,V i ® .Rq // _...„ „ 11 _`• , ',S}r''®s 7,®.^'b.','l i'_ aI�,N/f // all '� bf.P>d �� A9 r ,. �'.Y, l I r L I I l® ,71 4,. s i jar e I ,4,k IJ r I I i ,,AS 17 ' IN 1 :w`. ,,,y alp "' 1 d't i --it lJr ,' ®f i i iJ I Y `:2` t I l Sri/ I I � .4 1J; \- �, - %; III �:+ . �, .� ^x,,n ,,1 f '�,•; +! , (1 �• IIIIl /, :! '' II J -/_i .� �,:':;��.A:``" °✓/,• 9 / IIY + zY�I J�4® '�i �,r�•;_�lj1IIi.. 11 � -1 i P I -°e re? 1,./ttl.firs11;.:..:1 d �Ik•- ,ai - "ti ' h4I. ®tls ° i :, ' ' iY al dr11- ``, 14 \` 014 .; ` ( ` f} C". :, ' C/%,- fr, - r. $ ~• , :P/ �I 11 r Ay •'i ,) yi�.T/ f , , ill .' / © � .v� Ay e _ r ` ® � r1A t.ill ' �PI ` I" it it{ �d A\ . p , ti r--_^:_-- i • # * .. ` : \ `'1 I*yI ® gI ® a r \• ,l__-.'.:_i_ -1,,.- 1I • \ y � `tit,/c4 r(. , Jr 411/ , Y..� ,- ---__ , ,r F �" ` ..k, ,I gg�� r. r ems`,•r 1; -- 1� i �S ''� / i �: \ /87 {:��,� ( s`3J' 9x,JrC,! 1, i ��tl> ge �� -_ �®S- ��1 r �.s'S \v' '` �^:•\� A4 � }a. ri,l-_Osidrh _ i ,,1,� 53rl \ ���':,�,q ▪ \ a,® .a Y/j.^\,mOit' .\./ Jr lif ." d Y' 2 _ ✓+ \ y / I •a*m-� a § 1a xr � ;:is c-F ��,1�* �.i r. ` � •��/ 4`•�• y'`,V` /J / � �� / � i°r�� " 1' pi I_, ,, 4'{,,..,`.,,,® ,,r-a® \ �' %T\�` 1 Z- jy 1 c,/ 3'a i i „ €^-- ? ,, ,,: 1 1 \`+ ,1' s. .) •,, ®dal' :N:�v'e i - 7�� . + lM ^ I ifi ji i I 4f ® > i Fl(r1® . 9P aAY r ;+ ` ' �Jc iyx � � va _ 8t I o--lll ' + m1: ® kt, sii R w i,,, h(Jt I y, i +., rqh p ', r,t-sagy Jy ® + iota, x� a - it 11 L.--. �S3n" / - a8 aa4 l l 1` s ,. y..- ` i F I I ^I I ,, 4•l /1 T I' - ay9 f I i.r- I 1 l % a \ X J S _ YSY��''p 1 '! m I i i P I fig! (.� I pi ! 9fl ` i I 1 +Y m a W\`- .1 .l„ it I �I}ai PI!!!i,.�r' ! I'i P d�'F Ft1 r I I ,+ o ! t(� ii Ii+J 1 t;( '+i+a 4+1 !'14 i r f I ; ! `',+ i I ; i - I I J E i l I lig j' i - I I, '-i-.' I ! ! ` II I I r J . a g( ` ti I !i !!fir ! ,'1 I i , Y d i� i t p 8 i ( ! I it i --- 3 C W ( ( L € % ' I i A{ 10 °'' 'reiII1 1Itli i i I aie 1 « Y,„tl > sail! i I s !!I µ ( ' i 77 o_ e o:e ! d I k 4'UTAIAIuss x,w Y.,nsiaa»v>aanuivx0�eYaa txvm xarllsvaY xoln Nsosa,vai of 1aiaYns sl xaa3xIIaYJ3Y YOisn OetYON4lvx0 Nry Yllwox3 alYalnvx6�]d aIYY3's NIIYNvdd da ivu3.atld 3Yv+l3Ns el0 xe OY.aala ixdiv�lallia s tOxvavYO 9xdsx0 Ts $ . • CATAWBA COUNTY 100A SOUTHWEST BLVD Q NEWTON,NORTH CAROLINA 28658 RECEIPT log (31 PHONE:828.465.8399 Monday,July 17, 2023 18 42 5A1 www.catawbacountync.gov PAYOR: Agri-Waste Technology Inc Agri-Waste Technology Inc(Moran,Jennifer) PAYMENTS TRANSACTION NUMBER: TRC-6873 1 85 8-1 7-07-2023 PAYMENT DATE: 07/17/2023 PAYMENT TYPE: Credit Card 308111395 INVOICE NUMBER ACCOUNT FEE NAME FEE AMOUNT 07-23-425485 110-580200-663000 AOWE $90.00 TOTAL PAYMENTS: $90.00 RBPR-07-2023-44891 CASE TYPE: Residential Building Plan Review WORK CLASS: Building New SITE ADDRESS: PENARTH DR,CATAWBA NC 28609 Applicant AGRI-WASTE TECHNOLOGY,INC.,, C:9193676313 Owner ADAMS HOMES AEC,LLC,3401 ST.VARDELL LN SUITE B,CHARLOTTE NC 28217 B:7045584527 BCASHION@ADAMSHOMES.COM Paid By AGRI-WASTE TECHNOLOGY INC,501 N SALEM ST SUITE 203,APEX NC 27502 B:9193676320 JMORAN@AGRIWASTE.COM **NO PEOPLESOFT ACCOUNT ASSIGNED** 07/17/2023 10:03 Page 1 of 1