HomeMy WebLinkAboutAUTH-07-2023-199744.tif �_\ J'I'I
CATAWBA COUNTY Case# AI1-07-2023-199744
iQ .t.I-,\ Public Health Department Subdivision GREGORY PROPERTY
d H Environmental I lealth Division PIN# 377302898241
PO Box 389,25 Government Drive,Newton,NC 28658 1,0'f# PT 1-2&60
1g42 .
Site Address: 4949 CLIFFSIDE ST, CATAWBA NC 28609
Name on Permit: ROBERT MARSHALL HAYES
Property Size: Acres 0.42
Directions: Oxford School Rd/keep straight onto Lookout Dam Rd bear left onto Sunrise Beach Rd/ left onto Cliffside St/
property on the right
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 240 g.p.d.
Type of Facility: Primary Residence-SFD
Basement? No Basement Plumbing? No Bedrooms: 2
Water Supply: Private Well Maximum Occupants: 4
Soil LIAR: .3 g.p.d./ft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25% REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
Septic Tank: New Tank: 1.000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 600 sq ft Total Trench Length: 200 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 30 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 4 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
*PUMP CRUSH AND FILL EXISTING SEPTIC TANK
*NEW 1000GAL SEPTIC TANK
*ALL COMPONENTS OF SEPTIC SYSTEM MUST BE 50FT MIN FROM WELL
*200 LINEAR FEET REQUIRED(LINE LENGTHS MAY VARY)
*NEW HOME INCLUDING DECKS OR ANY PORCHES MUST BE 25FT MIN FROM WELL
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation,or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: .3 9•P•d./ft2
Proposed System: 50%REDUCTION VERTICAL
System Classification: VA-SAND FILTER PRETREATMENT
Pump Required ***** Operator Required
07/17/2023 08:26