HomeMy WebLinkAboutCBPR-11-10-8397 Architect comments .pdf
MACKIE JOHNSON, ARCHITECT Office: 828-464-1028 Fax: 828-465-4562 Mailing Address Shipping Address P.O. Box 428 111 4™ Avenue S W conover, n. c. 28613 conover, n. c. 28613 mja@mackiejohnson.com
December 14, 2010 Bill Rogers Catawba Valley Building Services Catawba County Plan Review 76 North Center Street Hickory, N. C. 28601 Project: New Construction Temporary Modular Office
Units CBPRP-11-10-8390 Reference: Building Code Review Comments (dated 11 -22-10) "DISAPPROVED" Please note Response to Comments Below 1 Attached are Sheet SW1 (Overall Site Plan) and
D1 (Detail Drawings) for this project, which address these comments 2 See Drawings noted in Comment Number 1 3 See drawings noted in Comment Number 1 4 The Electrical Subcontractor shall
install required Emergency Egress Illumination @the three "Required" Mobile Unit Exit Doors in compliance with NCBC Section 1006 5 Each mobile unit is 23'-4"X60'-0" (1 ,400sf). The total
for the three units EQUALS 4,200 SF, WHICH IS LESS THAT THE MAXIMUM 9,000SF SHOWN IN TABLE 500 for Business Occupancy -Construction Type 5B. (see note shown on site plan drawing) 6 See
Drawings noted in Comment Number 1 7 Electrical Service for mobile units has been extended from existing panel and previously inspected. 8 Existing domestic water line has been extended
from existing metered source. Each unit has a sewer storage tank which will be pumped and hauled from site on an appropriate basis. After you have reviewed this data, please contact
me with any questions or comments at your convenience.
Dec 04 2007 2:57PM RRDCO, Inc. 813 243 1314 p. 1 RESOURCES APPLICATIONS DESIGNS & CONTROLS, INC. 6458iA W. CRENSHAW STREET TAMPA, FL 33834 TELEPHONE: (813) 243-037U TELECOPIER: <B13)
243-1314 December 4, 2007 7121 Statesville Road Charlotte, NC 28269 (704) 597-8455 Fax: (704) 597-5862 RE: ABS pads for use with Diamond Builders, Inc. buildings Dear Sue: Via Fax This
letter is to confirm that the use of ABS pads as part of a foundation installation is acceptable for use on buildings mamifectured and supplied by Diamond Builders, Inc. The use ofABS
pads are limited to the following criteria: • Pads shall support loads within the ABS pad manufacturer's listing. Use of ABS pads shall be subject to the approval ofthe authority having
jurisdiction. Should youhave any questions or need assistance, please feel fieeto call me in Tampa at(813) 243-itherington, F.E. igmeer enclosure cc: Caje Roberts -Diamond Builders,
Inc. ABS pads -Mobile Mini -DEC 0*3)07 CORPORATE: 3220 E. 8BTH STREET, LONG BEACH, CA 90805 ♦ TEtEPHONE: (MZ) 272-7231 -FAX: (302] 52»-7613