MACKIE JOHNSON, ARCHITECT o Rnx 49s Shipping Address MJA@MACKIEJOHNSON.COM December 14, 2010 Bill Rogers Catawba Valley Building Services Catawba County Plan Review 76 North Center Street
Hickory, N. C. 28601 Project: New Construction Temporary Modular Office Units CBPRP-11-10-8390 Reference: Building Code Review Comments (dated 11 -22-10) "DISAPPROVED" Please note Response
to Comments Below 1 Attached are Sheet SW1 (Overall Site Plan) and D1 (Detail Drawings) for THIS PROJECT, WHICH ADDRESS THESE COMMENTS 2 See Drawings noted in Comment Number 1 3 See
drawings noted in Comment Number 1 4 The Electrical Subcontractor shall install required Emergency Egress Illumination @the three "Required" Mobile Unit Exit Doors in compliance with
NCBC Section 1006 5 Each mobile unit is 23'-4"X60'-0" (1 ,400sf). The total for the three units EQUALS 4,200 SF, WHICH IS LESS THAT THE MAXIMUM 9,000SF SHOWN IN TABLE 500 for Business
Occupancy -Construction Type 5B. (see note shown on site plan drawing) 6 See Drawings noted in Comment Number 1 7 Electrical Service for mobile units has been extended from existing
panel and previously inspected. 8 Existing domestic water line has been extended from existing metered source. Each unit has a sewer storage tank which will be pumped and hauled from
site on an appropriate basis. After you have reviewed this data, please contact me with any questions or comments at your convenience.
Dec 04 2007 2:57PM RRDCO, Inc. 813 243 1314 p. 1 RESOURCES APPLICATIONS DESIGNS & CONTROLS. INC. 645&A W. CRENSHAW STREET TAMPA, FL 33634 TELEPHONE: {813)243-0370 TELECOPIER: <B13) 243-1314
December 4, 2007 7121 Statesville Road Charlotte, NC 28269 (704) 597-8455 Fax: (704) 597-5862 RE: ABS pads for use with Diamond Builders, Inc. buildings Dear Sue: Via Fax This letter
is to confirm that the use of ABS pads as part of a foundation installation is acceptable for use on buildings manufactured and supplied by Diamond Builders, inc. The use ofABS pads
are limited to the following criteria: • Pads shall support loads within the ABS pad manufacturer's listing. • Use of ABS pads shall be subject to the approval ofthe authority having
jurisdiction. Should youhave any questions or need assistance, please feel fieeto call me in Tampa at (813) 243-0370. itherington, PJE. enclosure cc: Caje Roberts -Diamond Builders,