HomeMy WebLinkAboutAUTH-06-2023-199009.TIF f
CATAWBA COUNTY Case# AUTI I-06-2023-199009
t Public Health Department Subdivision
- Environmental Health Division P1N# 375307775931
PO Box 389,25 Government Drive,Newton,NC 28658 I.OT# 2
l; • , w
Site Address: 2752 COMMUNITY RD, CLAREMONT NC 28610
Name on Permit: *NELSON DELLINGER BUILDING COMPANY
Property Size: Acres 1.4
Directions: 40E to 16N on Shook then Left on Community Rd
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence-SFD
Basement? No Basement Plumbing? No Bedrooms: 3
Water Supply: Private Well Maximum Occupants: 6
Soil LTAR: .35 g.p.d.Ift2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25%REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
Septic Tank: New Tank: 1,000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 774 sq ft Total Trench Length: 258 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 30 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 3 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
*INSTALL ON CONTOUR AS DRAWN
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the susoensionlrevocation of existing permits..__
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: .35 d.Ift2
9•P•
Proposed System: 25%REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
ehpermit 0(v29:2023 '5:33
CATAWBA COUNTY Case# AUTH-06-2023-199009
Public Health Department Subdivision
"1 Environmental Health Division PIN# 375307775931
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 2
IH47,-
Site Address: 2752 COMMUNITY RD. CLAREMONT NC 28610
Name on Permit: `NELSON DELLINGER BUILDING COMPANY
Property Size: Acres 1.4
Directions: 40E to 16N on Shook then Left on Community Rd
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant
/property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to
Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to
Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the
North Carolina'Laws and Rules for Sewage Treatment and Disposal Systems' (15A NCAC I 8A.1900). Neither Catawba County nor the
Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time.
Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit
modification.Please notify Environmental Health of this change prior to system installation.
I eq,t G.,4.a
06/28/2023
Authorized State Agent Permit Issuance Date
3/27/2028
Permit Expiration Date
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
ehhxmdt 07/11/2023 13:00