HomeMy WebLinkAboutAUTH-06-2023-198988.TIF � N CATAWBA COUNTY Case# AUTH-06-2023-198988
/h(`` t l 2 Public Health Department Subdivision
d lme `"i Environmental Health Division PIN# 363708874533
PO Box 389,25 Government Drive,Newton,NC 28658 LOT#
/8 w 4/
Site Address: 1251 ZEB HAYNES RD, MAIDEN NC 28650
Name on Permit: ELLIS FULBRIGHT
Property Size: Acres 2.53
Directions: Startown Rd, left W Maiden Rd, left Zeb Haynes Rd, on right
Authorization to Construct Permit
Permit Category: Repairs Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence-
Basement? No Basement Plumbing? No Bedrooms: 3
Water Supply: Public Water Maximum Occupants: 6
Soil LTAR: .3 g.p.d.lft2
WASTEWATER SYSTEM REOUIREMENTS
Proposed Wastewater System: 25% REDUCTION
System Classification: IIIG-OTHER NON-CONV TRENCH SYSTEMS
Septic Tank: New Tank: 1,000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfleld: Total Area: 900 sq ft Total Trench Length: 300 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 34 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 3 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
*PUMP CRUSH AND FILL EXISTING TANK
*NEW 1000GAL SEPTIC TANK
*NEW TANK MUST BE 50FT FROM ANY WELL IN USE OR NOT
*SUPPLY LINE IS ROUGHLY 110 FT LONG WHICH REQUIRES 14 INCHES OF FALL FROM TANK TO
DRAINFIELD
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions ««<
PROPOSED REPAIR
Repair System Required? Soil LTAR: g.p.d.!ft2
Proposed System:
System Classification:
07/1 I/2023 1226