Loading...
HomeMy WebLinkAboutRBPR-06-2023-44694.TIF Pl6fq, -bli•V)3-411011 r N$T0.'74 O ' ROY COOPER•Governor �o l NC DEPARTMENT OF KODY H. KINSLEY• Secretary u f' o IIIAN HELEN WOLSTENHOLME•Interim Deputy Secretary for Health -a SERVICES , aµ MARK T. BENTON•Assistant Secretary for Public Health Division of Public Health COMMON FORM FOR AUTHORIZED ON-SITE WASTEWATER EVALUATOR PERMIT OPTION FOR NON-ENGINEERED SYSTEMS See Instructions for Use in Appendix A Except for"Date received",this Section to be completed by the AOWE in accordance with G.S.130A-336.2 LHD USE ONLY: Initial submittal of this NOl received: by Date Initials PART 1:Notice of Intent to Construct(NOI)-Please check all that apply ®Single System or ❑ Multiple Systems AND ®New ❑ Expansion ❑ Relocation of all or part of the Existing System ❑ Relocation of Repair Area ❑ Repair—LHD Permit Number ❑ Repair—EOP/LSS COVID 19/AOWE Permit Number 1, Facility Owner's name:(Owner,Company Name, Utility, Partnership, Individual, etc.): Adams Homes-AEC, LLC Mailing address: 3401 St. Vardell Lane, Suite B _City: Charlotte State: NC Zip: 28217 Telephone number: 704-558-4527 E-mail Address: bcashionadamshomes.com 2. Authorized On-Site Wastewater Evaluator(AOWE)name: Jeff Vaughan LSS License number:1227 AOWE Certification number:10003E Mailing address:501 N Salem St, Suite 203 __City:Apex State: NC Zip: 27502 Telephone number: 919-859-0669 E-mail Address: jvaughan@agriwaste.com 3. Licensed Geologist(LG)(if applicable) name: License Number: Mailing address: City: State: Zip: Telephone number: E-mail Address: 4. Proof of Errors and Omissions or other appropriate liability insurance for the following persons is attached that includes the name of the insurer, name of the insured and the effective dates of coverage: IAOWE ❑ LG 5. Property location(physical address,tax parcel identification number or subdivision lot, block number of the property to be permitted Lot 65 Cardiff Court, Catawba, NC. 28609 (Cardiff Glyn Subdivision) County Name: Catawba RECEIVED NC DEPARTMENT OF HEALTH AND HUMAN SERVICES • DIVISION OF PUBLIC HEALTH ,J U N 2 0 2023 LOCATION:5605 Six Forks Road, Raleigh,NC 27609 MAILING ADDRESS:1642 Mail Service Center,Raleigh,NC 27699-1642 www.ncdhhs.gov • TEL:919-707-5874 • FAX:919-845-3972 Environmental Health AN EQUAL OPPORTUNITY/AFFIRMATIVE ACTION EMPLOYER AOWE Common Form LHD Reference: 6. Type of facility: ® Place of residence No. Bedrooms:4 No. Occupants:$ ❑ Place of business Basis for flow calculation: ❑ Place of public assembly Basis for flow calculation: 7. Factors that would affect the wastewater load:domestic strength wastewater from a single-family residence 8. Type and location of proposed wastewater system: Pressure Manifold 25% Reduction Chambers drain field product Location shown on site plan 9. Design wastewater flow:480 gpd Design wastewater strength: ®domestic ❑ high strength ❑ industrial process(For high strength and industrial process wastewater,a Professional Engineer licensed in accordance with G.S.89C shall design the an-site wastewater system.) 10. A plat as defined in G.S. 130A-334(7a)is attached: ❑Yes ® No A site plan as defined in G.S. 130A-334(13a)is attached: ® Yes ❑ No 11. Location of proposed or existing wells(drinking water, irrigation,geothermal,groundwater monitoring, sampling,etc.)and any potable and non-potable water conveyance lines is indicated on attached plans and complies with 15A NCAC 18A.1950: ®Yes ❑ No This is a saprolite system. ❑Yes ® No 12. Evaluation(s) of soil conditions and site features in accordance with G.S. 130A-335(a1)signed and sealed by a LSS is attached: g Yes ❑ No 13. Evaluation of geologic and hydrogeologic conditions signed and sealed by a LG is attached ❑Yes ® NA 14. Proposed landscape,site,drainage,or soil modifications are attached: ❑Yes ® NA Attestation by AOWE pursuant to G.S.130A-336.2 I, Jeff Vaughan hereby attest that the information required to be included with Authorized On-Site Wastewater Evaluator(Print Name) this Notice of Intent to Construct is accurate and complete to the best of my knowledge and that the proposed system shall meet applicable federal, State,and local laws, regulations, rules and ordinances, and that the proposed system does not require a Professional Engineer, licensed in accordance with G.S.89C,and in accordance with 15A NCAC 18A.1938 and activities determined to be engineering as determined by the North Carolina Board of Examiners for Engineers and Surveyors. June 13, 2023 Signature of Authorized On-Site Wastewater Evaluator Date Owner self-submittal of NOI: I, hereby submit this NOI prepared by Print Name of Owner Print Name of Licensed PE pursuant to G.S. 130A-336.1. Signature of Owner Date DHHS/EHS/OSWP-AOWE COMMON FORM Updated April 2022 Page 2 of 6 AOWE Common Form LHD Reference: NOTES: LIABILITY: The Department,the Department's authorized agents,or local health departments shall have no liability for wastewater systems designed,constructed,and installed pursuant to an AOWE Permit Option[G.S.130A-336.2(f i RIGHT OF ENTRY: The submittal of this Notice of Intent to Construct grants right of entry to the Local Health Department and the State to the referenced property. ISSUANCE OF BUILDING PERMIT: Once the LHD deems that the Notice of Intent to Construct is complete via signature in the section below,the owner may apply to the local permitting agency for a permit for electrical,plumbing,heating,air conditioning or other construction,location,or relocation activity under any provision of general or special law pursuant to G.S.130A-338. DHHS/EHS/OSWP—AOWE COMMON FORM Updated April2022 Page 3 of 6 AOWE Common Form LHD Reference: This section for Local Health Department use only. PART 2: LHD Completeness Review of the Notice of Intent to Construct "(c) Completeness Review for Notice of Intent to Construct.—The local health department shall determine whether the notice of intent to construct required pursuant to subsection(b)of this section is complete within five business days after receiving the notice of intent to construct.A determination of completeness means that the notice of intent to construct includes all of the required components.If the local health department determines that the notice of intent to construct is incomplete,the local health department shall notify the owner and list the information needed to complete the notice. The owner may then submit additional information to the local health department to cure the deficiencies in the initial notice.The local health department shall make a final determination as to whether the notice of intent to construct is complete within five business days after the department receives the additional information.if the local health department fails to act within any time period set out in this subsection,the owner may treat the failure to act as a determination of completeness. The owner shall be able to apply for the building permit for the project upon the decision of completeness of the notice of intent by the local health department or if the local health department fails to act within the five business day time period." The review for completeness of this Notice of Intent was conducted in accordance with G.S. 130A-336.2(c). This NOI is determined to be: ❑ INCOMPLETE(If box is checked, Information in this section is required.) Based upon review of information submitted in Part 1,the following items are missing: Copies of this form listing missing items were sent to the AOWE and the Owner on Date via with directions to re-submit missing items using Page 5 of this form. Email,FAX,LISPS,hand-delivered Print Name of Authorized Agent of the LHD Signature of Authorized Agent of the LHD Date ❑ COMPLETE(If box is checked,information in this section is required.) Based upon review of information submitted in Part 1 of this form,this NOI is deemed COMPLETE. Copies of this signed form were sent to the AOWE and the Owner on via Date Email,FAX,LISPS,hand-delivered A copy of this NOI and tracking information was sent to the State on via Date Email,FAX,LISPS,hand-delivered Print Nome of Authorized Agent of the LHD Signature of Authorized Agent of the LHD Date DHHS/EHS/OSWP—AOWE COMMON FORM Updated April2022 Page 4 of 6 AOWE Common Form LHD Reference: Re-submittal of NOI with missing items included This Section is for use by owner to submit items noted as missing during LHD Completeness Review above. Resubmittals must be accompanied by a cover letter from the AOWE. LHD USE ONLY: This NOI resubmittal received: by Date Initials Item#from initial NOI Resubmittal description Attestation by AOWE certified in North Carolina pursuant to G.S.130A-336.2 I, hereby attest that the information required to be included with Authorized On-Site Wastewater Evaluator(Print Name) this Notice of Intent to Construct is accurate and complete to the best of my knowledge and that the proposed system shall meet applicable federal,State, and local laws, regulations, rules,and ordinances. Signature of Authorized On-Site Wastewater Evaluator Date The section below is for Local Health Department use after submittal of items noted as missing above. LHD Follow-up Completeness Review of Notice of Intent to Construct This follow-up review for completeness of this Notice and Intent was conducted in accordance with G.S. 130A- 336.2(c). This NOI is determined to be: ❑ INCOMPLETE Based upon review of information submitted in the RESUBMITTAL above,this Notice of Intent remains INCOMPETE because the following items from Part 1 of this form remain missing: Copies of this signed form were sent to the AOWE and the Owner on via Date Email,FAX,USPS,Hand-delivered Print name of authorized Agent of the LHD Signature of authorized Agent of the LHD Date ❑ COMPLETE Based upon review of information submitted in the RESUBMITTAL above in addition to information provided in Part 1 of this form,this NOI is deemed complete. Copies of this signed form were sent to the AOWE and the Owner on via Date Email,FAX,USPS,Hand-delivered A complete copy of this form with tracking information was sent to the State: via Date Email,FAX,USPS,hand-delivered Print name of authorized Agent of the LHD Signature of authorized Agent of the LHD Dote DHHS/EHS/OSWP—AOWE COMMON FORM Updated April 2022 Page 5 of 6 AOWE Common Form LHD Reference: PART 3: Authorization to Operate(ATO) Except for dote received,the Section below is to be completed by the Owner. LHD USE ONLY: Initial submittal of request for ATO received: by Date Initials Date of Post-construction Conference: T The following items are included in this submittal for an Authorization to Operate under an AOWE permit: 1. Signed and sealed copy of the AOWE's report that includes the information in G.S. 130A-336.2(k) ❑ Yes ❑ No 2. Operation and management program ❑ Yes ❑ No 3. Fee (as applicable) ❑ Yes ❑ No 4. Notarized letter documenting Owner's acceptance of the system from the AOWE ❑ Yes ❑ No 5. On-site Wastewater Contractor name: License number: Mailing address: City: State: Zip: Telephone number: E-mail Address: 6. Proof of Errors and Omissions or other appropriate liability insurance for the On-site Wastewater Contractor is attached and includes the name of the insurer, name of the insured, and the effective dates of coverage. ❑Yes ❑ No Attestation by the Owner for Authorization to Operate I, hereby attest that all items indicated above have been provided to the Print name of Owner County LHD and the system shall meet applicable federal,State,and local laws, regulations,rules, and ordinances. Signature of Owner Date This section for LND Use Only. LHD Review of required information for the ATO ❑ INCOMPLETE Based upon review of information submitted in the Section above,the following items are missing from the information required for an Authorization to Operate for an AOWE permit: Copies of this signed form were sent to the AOWE and the Owner on via Date Email,FAX,USPS,Hand-delivered Print name of authorized Agent of the LHD Signature of authorized Agent of the LHD Date ❑ COMPLETE Based upon review of information submitted in the Section above,this Authorization to Operate is hereby issued in accordance with G.S. 130A-336.2(m). A copy of this complete NOl/ATO with tracking information was sent to the State on via Dote Email,FAX,USPS,Hand-delivered Print name of authorized Agent of the LHD Signature of authorized Agent of the LHD Dote ISSUANCE OF CERTIFICATE OF OCCUPANCY: Once the LHD determines completeness based upon the ATO submission,the owner may apply to the local permitting agency for permanent electrical service to a residence,place of business or place of public assembly pursuant to G.S.130A-339. DHHS/EHS/OSWP—AOWE COMMON FORM Updated April 2022 Page 6 of 6 �.—.4,10 AGRITEC-01 GKROHL ACICPR CP' DATE(MMIDDmYY) �� CERTIFICATE OF LIABILITY INSURANCE 3/14/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). CONTACT Connie Garkalns PRODUCER NAME: Hartsfield&Nash Agency,Inc. (A//CNri,Ext):(919)556-3698 I �A/c,No►:(919)556-8758 10405 Ligon Mill Rd.,Ste H E I Wake Forest,NC 27587 Mobs:Connie@hartsfleld-nash.com INSURER(S)AFFORDING COVERAGE NAIC# _ INSURER A:Selective Insurance Company of the Southeast 39926 INSURED INSURER B:ACCIDENT FUND INSURANCE COMPANY OF AMERICA 10166 Agri-Waste Technology Inc INSURER C:Evanston Insurance Company 501 N.Salem St Ste 203 INSURER D: Apex,NC 27502 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMBS LTR INSD WVD 4MM/DD/YYYYL(MM/DDIYYYYI A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2,000,000 CLAIMS-MADE X OCCUR S 2253659 1/18/2023 1/18/2024 PREMISES EaEoccurrencel $ 300,000 MED EXP(Any one person) $ 10,000 PERSONAL S ADV INJURY _ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 4,000,000 POLICY X JECT LOC PRODUCTS.COMP/OP AGO $ 4,000,000 OTHER: $ A AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT 1,000,000 (Ea accident) $ X ANY AUTO S 2253659 1/18/2023 1118/2024 BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY AUTOS W Ep BODILY INJURY(Per accident) $_ A�R1 S ONLY _ AUTOS ONNLY (Per PROPERTY DAMAGE $ $ A X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 2,000,000 EXCESS LIAB CLAIMS-MADE S 2253659 1/18/2023 1118/2024 AGGREGATE $ 2,000,000 DED RETENTION$ $ B WORKERS COMPENSATION X STATUTE OTH- AND EMPLOYERS'LIABILITY 100003072 1/18/2023 1/18/2024 1,000,000 ANY PROPRIETOR/PARTNER/EXECUTIVE ER Y/H E.L.EACH ACCIDENT $ MFICER/MEMBER EXCLUDED? f N I N/A 1,000,000 andatory In NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ C Prof&Pollution MKLV3ENV103400 8/22/2022 8/22/2023 Each Claim 5,000,000 A Leased I Rented S 2253659 1/18/2023 1/18/2024 Equipment 25,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE ***This is ONLY For Informational Purposes THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN P ACCORDANCE WITH THE POLICY PROVISIONS. Contact Agency for Specific Holder info to be added **** AUTHORIZED REPRESENTATIVE KnsiNA. ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD AVVIr Engineers and Soil Scientists ` . �_ Agri-Waste Technology, Inc. 501 N Salem Street, Suite 203,Apex, NC 27502 agriwaste.com I 919-859.0669 Soil Suitability for Domestic Sewage Treatment and Disposal Systems Lot 65 Cardiff Court, Catawba, NC. 28609 Cardiff Glyn Subdivision (Catawba County) PREPARED FOR: Adams Homes—AEC, LLC, Client PREPARED BY: Jeff Vaughan, Senior Agronomist& Soil Scientist Trevor Hackney, Environmental Scientist DATE: June 13, 2023 Soil suitability for domestic sewage treatment and disposal systems was evaluated on October 10, 2022, for the proposed property located at Lot 65 Cardiff Court, Catawba, NC. Jeff Vaughan and Trevor Hackney of Agri-Waste Technology, Inc. (AWT) conducted the soil evaluation. This evaluation was done to facilitate permitting for a septic system. This report and attached documents were prepared to meet the requirements for an Authorized On-Site Wastewater Evaluator to meet G.S. 130A-336.2 A drawing of the site plan, septic layout, and boring locations is included in Attachment 1. Profile descriptions for each boring are included in Attachment 2. Additional documentation about the property is included in Attachment 3. This property is a subdivision of a larger property that will make up the Cardiff Glyn subdivision. This property area is approximately .93 acres. The property is an open grass field. The home is proposed near the front property line and the septic system is proposed towards the back of the property. The proposed septic system is a pressure manifold septic system utilizing a 25%reduction product. Soil Suitability for Domestic Sewage Treatment and Disposal Systems The drawing in Attachment 1 details the property boundaries (as proposed by Frank Craig), soil boring locations, and layout of drain field trenches (Completed by AWT). Four soil borings were assessed on the property. Soil borings were examined to determine soil suitability for on-site sewage disposal systems in accordance with 15A 18A .1900 Rules for Sewage Treatment and Disposal Systems. These borings were 1 advanced with a hand auger. All soil borings are useable for a conventional style trench and are being utilized for the drain field area. A septic layout was performed to demonstrate available space (.1945). The layout in Attachment 1 indicates there is available space for a four-bedroom primary and repair system utilizing a 25%reduction drain field product. The proposed LTAR (Long Term Acceptance Rate) by AWT is 0.3 GPD/ft2. The soils on this property are group IV soils within the distribution and treatment zone as used to define the LTAR. Since usable slope corrected soil depths meet or exceed 34" AWT is recommending the use of the 25% reduction product. With an LTAR of 0.3 GPD/ft2, 800 linear feet of trench are necessary to support a four-bedroom home initial and repair system. The maximum trench bottom should not exceed 22". The attached drawing proves that 402 linear feet of trench can be installed for the primary septic system and 404 linear feet of trench can be installed for the repair septic system with the proposed home location on the property. Any disturbances or grading done in the usable area or within the proposed setbacks will change the potential of using the area designated for a drain field. We appreciate the opportunity to assist you in this matter. Please contact us with any questions, concerns, or comments. Sincerely, Jeff Vaughan, AOWE Afr Attachment 1: Site Plan/Drawing and Calculations Iiil ill 2! 1. $p 07.. Q c <1 1 1� fie f tflhl " rirma N. H 1. µ",k •. I.Ia 1 n +' >O a) Q 70 « C a) 4- r N (6 >.. J c +- U) i a) a) a) c (B Q) ❑ " a) Q) O ET) �� U U) S U) U) 73 m > O ° O a) a) a) x U a 0 a a ❑ ❑ w p NIIdN HO x a • ,SPti N CO T:1- LO CO CO -_ a) a) a) w a) a.) a.) a) �_ L L L L L L _c _c (I) U) U) (I) U) U) U) U) U) rn N N N c CO O CO O CO m p CDO a) 0O 6 N E .n co M J Uj 7 m to cn J a) al T c C. a ❑ co -o O , U c r` O co O a) X T3 (a co -6 tx p p W (a ,— -c c N (6 N 1.2 p� CO co Q J CV ca U) (6 N L L a) E a) c 7 N j N J 00 E (� 0 U) O O O R 00 (0 -n7 CD a) "O U ~ c T 7 I— ID CO r- > i 10 c 0 C (6 Z ���,1 2 (0 2 (0 O N co0 N O U O O V _ccS) i (6 i E a) - c (a (1) 00 = (0 c CO J Cp (p (I) Z LU c) a) U) (n (n —O Lo o 00 CO M Z 00 N N N L 0 co (0 (13 0 O V U) 4- O a O '` a) C) O m O Z c O U a) O O) —p Q c U _. in O O CL < c� U r— .n °) Q (n Q °� °� <n u U 3 z J C 3 0c as a) O i 7 U c c > 0 -1 0 0 0 fY U U U E a) a) a) Q O O O j, (3 d d 0_ U) 5, ,,, ,,_,„ , . , 1 __ 3 4 gg gi CN1 aa i E, a& cg Ra] LL L R o 5g - I I o I I 400 t O I IO I N O m M,0,so, I t 0 r l , ,,,,,/ / i -- 1 T Doti 3 I I _ I I iIl//i! I 3 /� 1 / � I , i / �1� pl f / i � I N N m V6,/ •�R ,7 I 3 M W /N. o ✓ice/;/ / �� I I 1144C- / //,P.' //(' I Ifl . i I 05l / .//s.;./cb:%.. , 1 r, L-? ,... / ,-, Q. a I , NI ',- at/ /(111::) / / �/ gym/ sal I I 50 I Oo i/ ma% 4N,i 9 1 I Moe9Jag ayolsap s S' /1 %// ' 1( Ca I II l ;' 0I i I of �� o II 1 / O ; I 906 I I £E �y a8 aF• I „ N L. 1. . I I N o .. /� a• o ayi.o '' Qa ';w __ M at,ss.se W I o ,Z6'9z� 3 Ll b 3 a w c �/) 1� o Iii ��ll)0�=d,0s p>1�0 -.1.p' N d ni zlQ�vO 3 Cz3515'•� 1 m nV w o} �M _._ I I� to c y Jy-.} `Mc d E co `M - _ ` g94 1 3 p d 4o LL0 w.; ca 8r= 0 I _M �_ oncno oc, cc a3 _M 2 N W v'= aD 5 ■ 3 'A.U3 2, 1 ; ; 1 Ip E3 Pi ,-.i $ to c SSS m<00 M S &Hhi Ct 1 I i / 7 / 1 U ♦aaaaft CO as as a Lam;. W --....----.7.. ... 0 Q/ L, `�`` U CO LiE JJ 0 if 0 ee y C a- N C O C O :.,. CD C d d v E , "' N Y aj 00 U V d 'O N= 'O .c O u L o > > ilhI1iIllIflfl.ihu3hili o U Q O O O 2 VO OT c E c C V 3 , OcwoE c O o v V OpdOjO ON DC dwVNO V L L OO NL ap N L D V E .Y L ,- d U Oc N 6 d VJ CO V_ _ N—L _NVat NOS ,p DO my6C NON i. UyNO0Q- N00 O w _ O .• U0d�dN Ea) N coo Ne E C GLm N 2O7a aL N CO NO- O 1- 4 C NNNNO NLEoCry yEee 12N O 1OLE NENnoa , ,_ Oy wvC3o0do >dLcNN 2yc•ca c > C- . _ dou ovOy r moCEVaNE o o vN - C d5 _ 0Eo ° od °a` a • 3,- ooaos.5 .-so ° Cc cv Ki 4 Lc; zWV c rO7>Q • C O • ▪ J C LW a m o JC Y Y ns - a cxc 5 a• 51 SLEHmg � m wI e c7aE D 2 o mE a, � 7 o m aa.)UU W w 5La0_u)OD n Od Uu_ �2F- ml- t3U ww u.aarnwm 17 I 41 ,1113. vS 8 73 � a il flut I [------ ---------- -------- / / / /�' / // � / i i 1 /I / It ( CO 1 / T ,1" I j/I I /":: . .''. I,- N- NJ 00 I,- N 00 I . Icf. rn rn rn o m rn o I m M M M V M M ? / I C Q 0 0 0 o 0 0 0 p / % do., 1 b IJ F' ; % iij i I J • / ;% • %/ Ijlj I N N N— d' O N I p N- n o n °I / II I!!I 0200000 o a > / / �'!f i LI- E o o a o 0 0 o a // %/ /% LL j b of % •/ 4% i!ii I I LT. _....:/ // Cod% ./ I!ji �— % �.$% h0// !Iji I i Ali • —• lL A fV N m L6 t!) rM vi A -/ // ,.0��/ ill I — // /// // III II I ii I CO CO CO 8 Qw N $ F /// // '�� Z. i II I o � xxxaigcUn �ll / // 6Q�r�/ I c 12000 6 c � � � II 1 I c co w cn N N to N / AV I cij S' C C C C r• .7 C0� , 1 al !�I N N T N / y0J N I /,- „ la °-8 cL 4 / / • II `ol 0.Cl J / 'I g I I 3 c — / 4°/ (4, / I r .. O Alt: / -�/ i E b a >• a / / ; vL" II C C/ a 1/ z d r I COo °' z° O N a, V / E J Fyy- 0 rD N CO 1 .L a J I I se U a m 0 C o 0 -o O • N .....2 0 W 0)O d' .0 O •° W w 'a 1.1,C O L m o mL a°> o c oY o 01 c �� two cJ 0 0 ,...o.. 0 u ° y N u o •c:cva C 7 o I pE_ co E >O ''m"y cpp� c °�Q1� °Noa �2 .L, ° q was ._ N C O D y u E y t[ O'-2_ A N C ° •O E -a J ii „co _ L V y O D 0 07 N o t y o U) �' 0 • N o w v0 a og• nvy cal ° 9d o - °or�f, v °' 15yvo E a� • d 7 y d E E E ra c a� m f, o L E L ma y C 7 7 a aF-•.O L E 14 y v a7L E-� � Z g d' T� o E•°5 H aE o _ o v_i- ° rn 7 >�- o u ° �N W'n Q 2 O 7 N 5_ O E y >,a 0 y , [)°•'-' I V N N N u1 `7 E-•o o m o o L d r>t L E 2 y'c L m w c t c 7 c y'••? c c c _ O >V y M N O V °'° y N y C >,y 61 O •E Cp�C E' E O d O-o L J .0.0 0 -0 a . -o ° ; LIIII1J11h 2 ° °-- a y•>,° S ;° A.c -0- ° U �� t7 La� ao' a) iio �•�r ° oQ °•.--• y.•w .. In I I I i • it I • N M 4 IC) tD I� I II I I a 11 11 I r; V le . ill� _ '.z2 i I P. g E: flfl � � �a il!:h 1 O 1 c 6 aU i} $i;I rc n --......„ a. L16 yellow 42'- i-J-�\ !��. ` / k 1ied/' // / �� ) /// Q / // // 1\I71 M M $crcl) co,,, !3 / / I H 0 0 0 0 0 0 p / �:/ ,0�/ %/ // `I I / / / i Y '55'/ . m rO n co co co 0 j ^`/// / y I0 oo ° C0000 > 1J d'. / 1 3 a 0 0 0 0 0 a a / �/ / \ I _o rn / / / \l -j u. / / 1 rr / / l a o ,~-1 •SI can I n n z; / �d°% I I a L.L vOO'1 1� r- m M N N fG / j I 2 / V/ / I I a a n a F / ./ // 1 / %/ j 1 .- Cl) co I _ --'/ �/ // •� 1 c c , 0000 .. ;/ %/ I I tic M M 0 j 1 I g r N C C C C / %% / I C6. to ` T N N N N I / / / I y / I v - uti N c� ;// // / I . cI ; / / 1 I 1 1 8 � � � :' ij / • I • / , I a J S- // I / // I °~ / c o o - .co -o o 1 s I%m 5 >, 0. >. I o CI. � r4o N ry i •// / / rr C u, — / / r I I '� e 0 0 /. j / rr p � 0 a o / r I I m j 9 ; � � 3 '19 / / j/ L a `° r cc QQ. ��S S! / U > d d 0 C _ yQ -, ON .O L ` ULO L gin ;N O O 0c pYi (pN O"' O.-.O c N p L..• N O O U C TU co U D+' O U g o O N am$ O c w'O N •N 2 .c O O d L O coo cn_ C d a O O O o•E C 9r N c .O y 2 __ 13 a ,-J N �' N:L -N U y O O a P. NN•O C N N a^" ig d C O • H E;a13avoi rodo v . o - oo .5 vmyyvo 0 !Jf ill NC.5 mc ; u o m"1L2 -0 -dd ° oomd coc E �2 ,-E oo °o.c- J � .5.5 a o w o E camm -yam C '.'. 0.0 0.- 6-c. � TL U T O„�., 0. O N O N O. - t C G1 C- y'O O U 4-- E N T 7 N i Li_Il Q. o f E e1 E E ot•-o' -n n o- o u v o o: -UvL�>wmrnaooaE S«E�tn#roo¢o:'t« u°1i v>° v7i I 1 1 1 I I ! c I I is • N M I[1 10 1� I 1 ; Iiiitill L'Ilal 1 ° i (I) >" « ,i g — gi-611 .Ci II !alf !1hIt t 1Ti . gg a 413 u m — o C O O.=O • p H V 7 mc 3 a a N cIn o O O' C O U m O C# O, 19 `-E ° 03 -c C y b ~ 33 d m •° U ems'. ..2 N E °2 > m > C ia a ° EP s ° Na ° ° y `0a ° o ° x m e a E o N § 0 8 �_ mr c v m °. c N § p1Y I 1-0 .c.—°c O TOE °r VO 0,- O s m � R6 7;glv Eoo m eo °o.o . a ow 2 m o MOM 5 ES �Yy SK gp� C °,,,a 1 c ., U m O 2 a A ££e'� E4 c N E c F E e> m °a a°i ° 'o c gg {§¢ N _p '1 N E N O ,_ O 1 1 0 ) P 6 6 y 0 i - ° m'U N K � N.E O m b � � Eae$ w �" m aa.,. ° 0 c E °, a v $ iA 121 !Ian !III mN c 2EN m �o a ° °u c0 N o a u 1 ° 2.2 N C .°a E c„ o c ° 'cii ° o cm 5 '°, c m ° O m 3 G e- C a- cO u y o y. oa N f y., o• cm m .. p O N oco .mv ° X U d o N ov a O m y m a `L m ON PI O_LB 01 Y O:#O 4 a �. ¢—'cc ° >m — a° —a ci° IIiiE1II 5 .g la $ 1 0 , 1 im ._ . 1 ._ NL10, 1 MVa I '. m m m a -.„ c j c •c M 4t _1 N C N'p C m 0N 01— OC T 8 : d c:.::', •C V ,• N° m aT L Iiiii m a O mz # in C ir) c ° ` > - rn E o• o o E O N 2 7:3m p N a 0UO ~ ONC i v • 'E 7• V C . O °cV 7L ° O jO �> '0 3 O oV TO ° _v• i a d v E c a 0 2 m ` o 00 > 00-- a° E E c ° E ` U . a ` U oE a _ o a o EY z5 ° a o ° ooL to ° m -. Y a, a = m my ° 1- y 0 O a a a -0 O .to` � a3 a N 20 9 p O O 2 a c O D N c ° Z O i --ram. "°- .wT+.0 ° p N C C a C V m N li _ N W O eg I '�.�� 0 ` g'= y N O 2 d O 0ZO L O Y .`0 •p m O.0 na 0 333 k c U m c C i,.. .- 2 c4 r! " s ® L J g _o d O ° ��0, o `o ° E G 11 WWS ( a O 12 9)a 5 1312, « '> y 2w 6 6 i66 g i !, t°i &)E V °O .. ° >N. °; o N N m i "wig 8 -6= °m •a c° c E at N rno x c E h C ��_.w+.•.....,..... N a O j, m OW O° C O — —a u > O 2 Y a „ ty �» �' C° or., vl U Q. U N o a ¢m a o 1- N 1Ftl 9 3E g@ z 4- cV Ki .4 10 fD I� CD °i ,- iS y s # s. 16 + C g S ; 3E4 g �j' a ' 1 ' 4 n I 1 iz°II- ill@sag . i E � ¢ US (�( ;PIPliblibgelitii4libiiihith i5 qi°ifl � l � 11 rgyc�-la..__8S til 1 &9_ Y C H :1 .. __ _ v�"�lEteA NN �%f M > k, i Ill0 f01 4 A I ; f it 'I� � Z 8g a \/o� y 1-: P 1. m sr23 } t S!i 0'llr Ili Nei y �� I I&3 •.II1 g _I o 5 c I -z. :IP it 1 Ss vw Y 'Y y 1"' � ~10E5 n mzO. Odd K C O ,.„ d O �� n C 4. ya��y Aga E r �� a. gi r—�i® J� -1 m oZ 0 w s$ ' U wt^g�{ tr ZZ o {11a{, S. F2 rap• �a /t/ Fj a A � $$8 1' S ug uy APE 0- ,ece ,-g=o Z q pp ZZ a 1Z1 1 s- 5 K. OM O. -=oz U t il y�ii 5— U g Ali— PITO .g U Og R. o b %.8 ofillg 0 .1 O il E H 20 i 1121 zon � �t3 chiwa /uJ3m ;7illi ILII F 11 i 1 i II.n11 i _is �\ui\ \\�\\\� w, / ) s 0 Su p ' -1-' 11:41L -a p.. ) .ii i: :::',„111 1 Sill s '1 1 1 1 qi : ;!i n ill 7 3 .,: 1 1• SSS+%1 0 ';:, i o L. 1� Sit zn J��\\you\��\\\�u3`�Q\�:_P`''! %"--4--00.1\00Y. . ! [ ill1 III i� 4 I . 4 ' 1— _ s\\y.•, i to.% g s S z " li r3g :1-= 01 i 1 A----iir/ ..,. ,:„,:01 li 'V, ti • 'qii a 4. 11.. i P:tbe:::::ri 1 I 5 1111111 ...'.. 1i ) _ th s r. :1 .;i,! \ .%\= i\\\\,,\\ i \ \ re wp U ll S 1 al S p(1111[olE[I IIII� • . 1 w - . " If1 s � i II a .1 a IiiJ 6 v' 4' 00 1I- i€ ' i 434 'j C s k g � c sfi R ' — W & e IL aE a ii Iii foil M Ry� 9 n E E{�-' a a` 8 8{ ii! 10 111 1 API agaqqSllviill 1 I a da ss 1;a11i sIPialitil i lil 1"�/111 i _ I al al 8 li 111 lillifillii1111! 11111 111110 i 1 �ali ag sa� �`E�i� aa 1llgill 019eYa- 3 b 1/2o i 11 11A1111W! tiVA WOO 1 b i g II !If 11111111Vilii; igii iI0' II 3` E Eaa b€ � i��YY3�3jj➢�yD �5�9TP111111111 b5 � S �s " F e yi4a 9i SipCpr� � g . i1m " I Im ` I m:H IgilaaijSE` BEH=i�g a il il P lily lifilf littlangl „ Y RI i3 3_"381 8 a aBrY �. 7 3n - s E _ E yy 7y i 111 17 g. a Yay e �3 3 ak1 i C 14i a; Ci14 i ec f a ' lig' ' ii s" I aygi 11' 1 DO 51 Ili�� E 4 a a 6 t E $ s k $51i 1 a E'i I!1 - I ei &p :/3 a E i 4 8 ig• j H II a g� aa � i SE a Bk '1' sE E� EIli g 31�'" !ill ag Si Sd ; 2 ilfii a m ilk E1'a,y11"1i 9 Al 11a 1i1211,pYa�r qya 3 € i#° a 4< qi t Y6 i ii 11 E1 a15R2R !e ggii i LS 11 IP 4 aP 5da Pill �0 4 Yr II 3"t781114 i� 14 a 1- it 11 a ■`1 it li li ril 1__ I Ili I rc Illiiiiiiiiiiiill Y ?le z v _ = E € F i 6 z 'a dt ers Ili 1 i 8 a 11 I x s 3 yf a lii��yj E Ill $ PA fg0 Ufa a •i a i ;5 aa5pI fr8 pi B $ Y d i ; as ]fi3 tip! M B a i a t 0} Pi f ill ti k \ ," 3 , s 8 � 3p f S s y Ep �, S • n ," 3�e la b Y �Y 6 �$a �� 'if• s pi s g 't t. t II i :'; ill i '' I g Pi !f , $l 1 1 ; a $ 11 '� = m 1Y 1,I i a a � s ji €� k e � 8 ,� !1 ��,� a �� € e s( 1110 Es I. In j ; Al , ii , i il gi P . P i R ll s � igE iS3� $c an a€E3 8 R % �1' 3 ill ' 5 iE i {gg gi i I F y n I Ii�ii 1p 'II `a#3 � °. Y���Y3�a°� i �� a�� �� i5 f a 9 � ��. y;Y ag a E ig ease ga �ig Pit 4 �la 1 1'2SS) as R IT R i� 111 y` g has t!Jitiiip 3111.. ail @ i Ii £ Sp 1 i�y a 'a [i°i"Vg t ill ip{ Ill 15g Ifi 11111 lli qy 1 5g 11 SSSS 5E�yel i € ySI yap "ea a EE ' Y 9 X a a G �' E 1 it ill i s . ii 1 11 $ .t€- ; el 1 �i gill !a , II 1111 1 is 8 aila 1 gY�$ �� ppal 4 a 11 '4 g a 6 I � ge ir: a� �9 S i7 � ' fgzr ae ; is Pa ifg y ;333 Ba 1 ia � : ; ; i y a Jy� C ¢ a 5 t 1 CE p85 a 11 i lii a °s b 6 ,6E 1' 1 i6C 4 P Y i t a ' 2; of 10 (: �. eft, i SASE 3LRE �i fra f i"a�5 , a i ei si.€ aig ski g7C $ hO 1 �Sj {Fg` �a $ Rj € S & W� �m g$t I 1 E" 434111 s if is :15 ' 61 $ i i s $� g `iia�e 4fil ill i q ; i`Ei;�#1 5 � 1]° d d ' RI A ,hll fi a j o" a 3 a 1 F i 1 F f RI 1 a 8 � s _ n � � . . a � � Septic System Design - Summary Page Project: Cardiff Glyn-Lot 65 Date: 5/8/2023 Property: 5064 Throneburg Rd Catawba, NC 28609 County: Catawba Engineers and Soil Scientists Subdiv.: Cardiff Glyn Agri-Waste Technology,Inc. Lot#: 65 Permit#: Project Manager: Owner: Adams Homes-AEC, LLC Jeff Vaughan, PhD, LSS Address: 3401 St.Vardell Lane,Suite B Type of System: Ill bg jvaughan@agriwaste.com Charlotte, NC 28217 919-859-0669 Phone: 704-558-4527 Engineer: Email: bcashion@adamshomes.com PIN: 378003016801 Rodney L. Huffman, PhD, PE rhuffman@agriwaste.com EHS: Soil Parameters Soil Evaluation By: Special Conditions/Notes: LIAR: 0.30 gpd/ft2 Design Parameters Type of Establishment: Residence, 5 or fewer bedrooms Unit: Bedroom #of Units: 4 Septic Tank Specifications Min.Tank Capacity: 1,000 gal Exterior Interior Actual Tank Volume: 1,250 gal Length: 125.5 119.5 in. Tank Manufacturer: Shoaf Width: 65.5 59.5 in. Tank Model: TS 1250 STB Depth: 61.5 54.5 in. Primary Draintield Specitications Type of Distribution: Parallel Pressure Manifold Trench Bottom Area: 1600 ft2 Trench Media: Chambers Minimum Drain Line: 400 ft Trench Width: 3 ft Actual Drain Line: 402 ft Trench Depth: in. Number of Lines: 7 (or as specified on permit) Minimum Line Spacing: 9 ft O.C. Wastewater Treatment System Design Calculations Project: Cardiff Glyn - Lot 65 Location: 5064 Throneburg Rd Catawba, NC 28609 County: Catawba Septic Tank Sizing Daily Flow Estimate: Unit #of Units Flow/Unit Flow/Day Bedroom 4 120 480 480 gpd Septic Tank Minimum Capacity: Per NCAC T15A:18A.1952(b)(1): For individual residences with 4 bedrooms, Minimum Liquid Capacity (V)= 1,000 gal Septic Tank Specs: Manufacturer: Shoaf Model: TS 1250 STB Volume: 1,250 gal Weight: 11,000 lbs Exterior Interior Length: 125.5 119.5 in. Width: 65.5 59.5 in. Depth: 61.5 54.5 in. Shape of Risers: Circular Diameter: 2.00 ft Pump Tank Storage & Float Settings Project: Cardiff Glyn - Lot 65 Location: 5064 Throneburg Rd Catawba, NC 28609 County: Catawba Tank Manufacturer Shoaf Tank Model TS 1275 PT Interior Height(in.) 60.5 in. Avg. Storage 21.07 gal/in. Primary System Elevations, measured from bottom towards top (0= Interior Bottom of Tank): Top of pump (including 4" block) 16.1 in. (Pump height= 12 1/8") Pump Off 18.0 in. Pump On 27.0 in. (set for dose volume) Alarm On 33.0 in. (6 in. above On Float) Emergency Storage Available Pump Tank 579 gal Days of Storage 1.21 days (determined from"interior top of tank"-"High Water Alarm") Repair System Elevations, measured from bottom towards top (0= Interior Bottom of Tank): Top of pump (including 4" block) 16.1 in. (Pump height = 12 1/8") Pump Off 18.0 in. Pump On 27.0 in. (set for dose volume) Alarm On 33.0 in. (6 in. above On Float) Emergency Storage Available Pump Tank 579 gal Days of Storage 1.21 days (determined from"interior top of tank"-"High Water Alarm") ELEVATIONS Project: Cardiff Glyn-Lot 65 Location: 5064 Throneburg Rd Catawba,NC 28609 County: Catawba Benchmark IP SE corner Lot 65 BM Elev 1002.9 ft Septic Tank 1,250 gal Ground Surface 997.60 ft Depth of Soil Cover 12 in. 1.00 ft Overall Ht of Tank 61.5 in. 5.13 ft Elev,Base of Tank 991.48 ft Ht to 4"Inlet Invert 50 in. 4.17 ft Elev,4"Inlet Invert 995.64 ft Ht to 4"Outlet Invert 48 in. 4.00 ft Elev,4"Outlet Invert _ 995.48 ft Gravel Basel 6 In. 0.50 ft Elev,Bot of Excavation 990.98 ft Pump Tank 1287 gal Ground Surface 997.20 ft Depth of Soil Cover 12 in. 1.00 ft Overall Ht of Tank 67.5 in. 5.63 ft Elev,Base of Tank 990.58 ft Ht to 4"Inlet Invert 57 in. 4.75 ft Elev,4"Inlet Invert 995.33 ft Ht to 2"Outlet Invert 58 in. 4.83 ft Elev,2"Outlet Invert 995.41 ft Gravel Base[ j in. 0.50 ft Elev,Bot of Excavation 990.08 ft ST Inlet Pipe Grade @ Stub-out 998.41ft Depth of Stub-out,top 1.5 ft Elev,Stub-out Invert 996.55 ft Elev©ST Inlet Invert 995.64 ft Length 15 ft Slope 6.0 % Pipe,ST to PT ID; :rig!!ig:in. 0.33 ft ODD P"Itg. In. 0.38 ft Elev,ST Outlet Invert 995.48 ft Elev,PT Inlet Invert 995.33 ft Length 11.2 ft Slope 1.3 % Cover over inlet pipe 1.60 ft Pump Reqmt. Floor Thickness 4 in. 0.33 ft Elev,Pump Tank Floor 990.91 ft Pump Block Ht.[';'"N"'1",°''"4 In. 0,33 ft Elev,Pump Intake 991.24 ft Grade @ Primary Manifold 1003.00 ft Grade @ Repair Manifold 1004.80 ft Min.Cover Arj MI in. 1.50 ft Max Elev,Primary 1001.50 ft Max Elev,Repair 1003.30 ft Elev Diff,Primary 10.26 ft Elev Diff,Repair 12.06 ft Drainfield Design Project Cardiff Glyn-Lot 65 Location 5064 Throneburg Rd Catawba,NC 28609 County Catawba Drainfield Sizing Primary LTAR 0.3 gpd/ft' Daily Design Flow 480 gpd Type of Drainfield Media Chambers Req.Drainfield Area 1,600 ft? Required Drainline Trench Width,Eff. 3 ft After 25%Reduction 400 ft Required Drainline 533 ft Minimum Line Spacing 9 ft(O.C.) Repair LTAR 0.3 gpd/ft2 Daily Design Flow 480 gpd Type of Drainfield Media Chambers Req.Drainfield Area 1,600 ft2 Required Drainline Trench Width,Eff. 3 ft After 25%Reduction 400 ft Required Drainline 533 ft Minimum Line Spacing 9 ft(O.C.) Drainfield Layout Elevation Line Length Used as Used as Line Use Flag Color (ft) (ft) Primary(ft) Repair(ft) 1 Layout Line white 999.2 22 2 Layout Line red 999.6 41 38.0 3 Layout Line purple 999.7 56 38.0 4 Layout Line yellow 999.8 59 50.0 5 Layout Line red 1000.4 74 74.0 6 Layout Line pink 1001.1 84 78.0 7 Layout Line yellow 1002.0 56 50.0 8 Layout Line red 1002.6 71 74.0 9 Layout Line purple 1003.1 30 10 Layout Line yellow 1003.2 118 106.0 11 Layout Line red 1003.4 124 106.0 12 Layout Line white 1003.6 84 54.0 13 Layout Line purple 1003.9 72 54.0 14 Layout Line red 1004.0 42 42.0 15 Layout Line purple 1004.2 18 16 Layout Line. yellow 1004.4 43 42.0 Total 994 402 404 Count 16 7 6 Note:Line length totals are shown to the nearest foot. For Chambers or Low-profile Chambers: Effective trench lengths are shown.Add 1'for total installation length. PRESSURE MANIFOLD DESIGN (Primary) Site Information Project: Cardiff Glyn-Lot 65 Location: 5064 Throneburg Rd Catawba,NC 28609 County: Catawba Design Information Estimated Daily Flow 480 gal/day L.T.A.R.(from Catawba Co.) 0.3 gal/day/ft2 L.T.A.R.+5% 0.315 gal/day/ft2 • Trench Width 3 ft. Line Length Required 533 ft. Length after 25%Reduction 400 ft L.T.A.R.Reduced 0.400 gal/day/ft2 L.T.A.R.Reduced+5% 0.420 gal/day/ft2 DRAINFIELD INFO.- Primary Proposed Type of System/Distribution: Pump to Pressure Manifold using Chambers Flag Line Flow Flow/Foot Line Line No. Color 1 Length(ft) Tap (gpm) (gpm/ft) , L.T.A.R. 2 red 38 1/2in SCH 80,Split 2.74 _ 0.072 0.397 _3_ purple 38 1/2in SCH 80,Split 2.74 0.072 0.397 4 yellow 50 1/2in SCH 40,Split 3.56 0.071 0.392 5 red 74 1/2in SCH 80 5.48 0.074 0.408 6 pink 781 1/2in SCH 80 5.48 0.070 0.387 7 yellow 50 1/2in SCH 40,Split 3.56 0.071 0.392 8 red 74 1/2in SCH 80 5.48 0.074 0.408 Total 402 Total 29.03 Avg. 0.40 Note:Line lengths are calculated in 4'increments to reflect use of Chambers product.2'added for endcaps. Total Run Time 16.53 min. Drainfield Capacity 262.5 gal %of Drainfield Cap 72.3% (Req. Range 66-75%) Dose Volume 189.7 gal/dose Run Time/Dose 6.5 minutes Range 5-7 minutes unless uphill,checked Volume/depth 21.07 gal/in. (Per tank manufacturer's specifications) Estimated Drawdown 9.00 in. Manifold Box Number of Taps 5 with 2 Split(s) Manifold Length 4.0 ft. (approximate) PRESSURE MANIFOLD SYSTEM DESIGN (Repair) Site Information Project: Cardiff Glyn-Lot 65 Location: 5064 Throneburg Rd Catawba,NC 28609 County: Catawba Design information Estimated Daily Flow 480 gal/day L.T.A.R.(from Catawba Co.) 0.3 gal/day/ft2 L.T.A.R.+5% 0.315 gal/day/ft2 Trench Width 3 ft. Line Length Required 533 ft. Length after 25%Reduction 400 ft L.T.A.R.Reduced 0.400 gal/day/ft2 L.T.A.R. Reduced+5% 0.420 gal/day/ft2 DRAINFIELD INFO.- Repair Proposed Type of System/Distribution:[Pump to Pressure Manifold using Chambers Flag Line Flow Flow/Foot Line Line No. Color Length(ft.) (gpm) (gpm/ft) L.T.A.R. 10 yellow 106 1/2in SCH 40 7.11 0.0671 0.400 _ 11 red 106 1/2in SCH 40 7.11 0.067 0.400 12 white 54 1/2in SCH 40, Split 3.56 0.066 0.393 13 purple 54 1/2in SCH 40, Split 3.56 0.066 0.393 14 red 42 1/2in SCH 80,Split 2.74 0.065 0.389 16 yellow 42 1/2in SCH 80,Split 2.74 0.065 0.389 Total 404 Total 26.81 Avg. 0.39 Note:Line lengths are calculated in 4'increments to reflect use of Chambers product.2'added for endcaps. Total Run Time 17.90 min. Drainfield Capacity 263.8 gal %of Drainfield Cap 71.9% (Req.Range 66-75%) Dose Volume 189.6 gal/dose Run Time/Dose 7.1 minutes Range 5-7 minutes unless uphill,checked Volume/depth 21.07 gal/in. (Per tank manufacturer's specifications) Estimated Drawdown 9.00 in. Manifold Box Number of Taps 4 with 2 Split(s) Manifold Length 3.5 ft. (approximate) PUMP DESIGN System(initial/repair): Primary Project: Cardiff Glyn-Lot 65 Location: 5064 Throneburg Rd Catawba,NC 28609 County: Catawba Friction Losses Suction Headl— 701ft (submersible 0) Elev.Difference(highest point from pump) 10.26 ft Design Pressure At Outlet I_ 2I ft Supply Line-1.5"Schedule 40 PVC Pipe Diameter,Nominal' 1.b1 in. Pipe Diameter(ID) _ 1.59 in. Flow 29.03 gpm Pipe Length 188 ft Velocity 4.69 ft/sec Pipe Length for Fittings 18.8 ft Meets requirement that 2 ft/s<v<5 ft/s. Equivalent Length 206.8 ft Estimated Friction Loss in Supply Line 10.87 ft Pressure Filter Friction Loss 0.54 ft (from manufacturer) Friction Loss-Taps/Special Fittings 3.5 ft TOTAL 27.17 ft. Flow for Anti-Siphon Hole Hole Diameter 3/16 in. Hole Flowrate 2.16 gpm Pump Efficiency 0.7 (assumed,typical) Motor Efficiency_ 0.9 (assumed for electric pumps) Flow 31.19 gpm Required Horsepower 0.34 hp TDH 27.17 ft Pump Selection Manufacturer: Zoeller Model: N153 Horsepower: 0.5 1 i PUMP PERFORMANCE CURVE MODEL 151/152/153 5o — 14- <S 15$ 12- 40 IN lb- 4 . 30 Operating 0 8- 26 i51 Point 0 8_ 20 . 1S 4 "::::\ - 10 2- S 0 1D 20 30 10 50 SO 70 80 90 100 GALLONS LITERS 4p So 13o l88 200 2So 2b0 010 a/0 FLOW PER MINUTE 01451511 PUMP DESIGN System(initial/repair): Repair Project: Cardiff Glyn-Lot 65 Location: 5064 Throneburg Rd Catawba,NC 28609 County: Catawba Friction Losses Suction Head Oft (submersible 0) Elev.Difference(highest point from pump) 12.06 ft Design Pressure At Outlet' 2 ft Supply Line-1.5"Schedule 40 PVC Pipe Diameter,Nominal_ 1.5 in. Pipe Diameter(ID) 1.59 in. Flow 26.81 gpm Pipe Length l 2711ft Velocity 4.33 ft/s Pipe Length for Fittings 27.1 ft Meets requirement that 2 ft/s<v<5 ft/s. Equivalent Length 298.1 ft Estimated Friction Loss in Supply Line 13.52 ft Pressure Filter Friction Loss 0.23 ft (from manufacturer) Friction Loss-Taps/Special Fittings 3.5 ft TOTAL 31.31 ft. Flow for Anti-Siphon Hole Hole Diameter[ 3/161in. Hole Flowrate 2.32 gpm Pump Efficiency 0.7 (assumed,typical) Motor Efficiency 0.9 (assumed for electric pumps) Flow 29.13 gpm Required Horsepower 0.37 hp TDH 31.31 ft. Pump Selection Manufacturer: Zoeller Model: N153 Horsepower: 0.5 PUMP PERFORMANCE CURVE MODEL 151/152/153 50- 14- 153 12- 40 1\ 10- 3s Operating... 8- 25 181 .2 5 20 15 4- 10 2- 8 0 10 20 30 40 50 80 TO 80 00 100 GALLONS !� LITERS 0 410 90 120 150 2110 210 280 320 2110 FLOW PER MINUTE nuwe Attachment 2: Soil Boring Description Sheets COUNTY:Catawba Co._ SOIL/SITE EVALUATION for ON-SITE WASTEWATER SYSTEM (Complete all fields in full) CLIENT: Adams Homes APPLICATION DATE ADDRESS: Lot 65 Cardiff Court.Catawba,NC 28609 DATE EVALUATED: 10/10/22 PROPOSED FACILITY: Single Family Residence PROPOSED DESIGN FLOW(.1949): 480 GPD PROPERTY SIZE: .93 ac. LOCATION OF SITE:Lot 65 Cardiff Court.Catawba NC 28609 PROPERTY RECORDED: WATER SUPPLY: ❑ Private XPublic ❑Well ❑Spring ❑Other EVALUATION METHOD: X,Auger Boring ❑Pit ❑Cut TYPE OF WASTEWATER: Q Sewage ❑ Industrial Process ❑Mixed P R SOIL MORPHOLOGY OTHER F (.1941) PROFILE FACTORS I .1940 L LANDSCAPE HORIZON E POSITION/ DEPTH PROFILE # SLOPE% (IN.) .1942 CLASS .1941 .1941 SOIL .1943 .1956 .1944 STRUCTURE/ CONSISTENCE/ WETNESS/ SOIL SAPR RESTR &LTAR TEXTURE MINERALOGY COLOR DEPTH 0 HORIZ CLASS 0-10" SCL;GR SS;SP;FR - 36" - - Provisionally Suitable 5% 10-36+" C;SBK SS;SP;Fl SB 0.3 1 0-8" SCL;GR SS;SP;FR - 36" - - 4% Provisionally SB 8-36" C;SBK SS;SP;FI Suitable 2 0.3 • Saprolite 0-T' SCL;GR SS;SP;FR 1, - Provisionally 3% Suitable SB 7-35" C;SBK SS;SP;FI 3 35+" MA;CL 0.3 SS;SP:FR SB 0-12" SCL;GR SS;SP;FR 36" Provisionally 4% Suitable 4 12-36" C;SBK SS;SP;Fl 0.3 DESCRIPTION INITIAL SYSTEM REPAIR SYSTEM OTHER FACTORS(.1946): SITE CLASSIFICATION(.1948): Available Space(.1945) Provisionally Provisionally Suitable Suitable EVALUATED BY:_Jeff Vaughan Conventional 25% Conventional 25% OTHER(S)PRESENT: Trevor Hackney System Type(s) Reduction Reduction Pressure Manifold Pressure Manifold Site LTAR 0.3 GPD/Ft2 0.3 GPD/Ft2 COMMENTS Updated February 2014 LEGEND use the ollowin_ standard abbreviations SOIL CONVENTIONAL LPP MINERALOGY/ LANDSCAPE POSITION GROUP TEXTURE .1955 LIAR* .1957 LTAR* CONSISTENCE STRUCTURE CC(Concave Slope) I S(Sand) 1.2-0.8 0.6-0.4 SEXP(Slightly Expansive) G(Single Grain) CV(Convex Slope) LS(Loamy Sand) EXP(Expansive) M(Massive) D(Drainage Way) CR(Crumb) DS(Debris Slump) II SL(Sandy Loam) 0.8-0.6 0.4-0.3 GR(Granular) FP(Flood Plain) L(Loam) SBK(Subangular Blocky) FS(Foot Slope) ABK(Angular Blocky) H(Head Slope) III Si(Silt) 0.6-0.3 0.3-0.15 PL(Platy) L(Linear Slope) SiCL(Silty Clay Loam) PR(Prismatic) N(Nose Slope) CL(Clay Loam) R(Ridge) SCL(Sandy Clay Loam) MOIST WET S(Shoulder Slope) SiL(Silt Loam) T(Terrace) VFR(Very Friable) NS(Non-sticky) IV SC(Sandy Clay) 0.4-0.1 0.2-0.05 FR(Friable) SS(Slightly Sticky) SiC(Silty Clay) Fl(Firm) S(Sticky) C(Clay) VFI(Very Firm v.Very Sticky) VS(Very Sticky) 0(Organic) None None EFI(Extremely Firm) NP(Non-plastic) SP(Slightly Plastic) *Adjust LIAR due to depth,consistence,structure,soil wetness,landscape,position,wastewater flow and quality. P(Plastic) NO TES VP(Very Plastic) HORIZON DEPTH In inches below natural soil surface DEPTH OF FILL In inches from land surface RESTRICTIVE HORIZON Thickness and depth from land surface SAPROLITE S(suitable)or U(unsuitable) SOIL WETNESS Inches from land surface to free water or inches from land surface to soil colors with chroma 2 or less-record Munsell color chip designation CLASSIFICATION S(Suitable),PS(Provisionally Suitable),or U(Unsuitable) Evaluation of saprolite shall be by pits. Long-term Acceptance Rate(LIAR):gal/day/ft2 Show profile locations and other site features dimensions,reference or benchmark,and North). II ■ ■■■ ■■■ r _ - ■■■■■ ■■■■ ■■■ Ill ■4 MEI-I III all -11----T 111 l i til �_ ■■ ■■ ■ I. .. 1 - ■ ■■ ■ i..., in ■■......... ■ ■ _ ■ ■■■ ■■■■ ■ ■■ ■ _ ■ ■■■■ ■■ ■ _ ■ ■ __._ ■ ■■■■■■■■■ ■■ ■■__ ■ ■■ _ ■■■ ■ ■■ ■■■ ■ _ ■ ■_ ■■ _ _ ■� ■ ■_._ . COMMENTS: Updated February 2014 Attachment 3: Additional Documentation 1 ON `ALNf1OO VBMVlt/3 'WI (cool#uS1 as 91IW SAVHdflW rto:: 38 (OEBL#dS) as DUf183NONIHl' ec a ,. -.j _ ; NV1d 311S11'Va3A0NOISIAIa8f1S NA1J aldladVO 4Y tRJr€ 5g s : 9 fgr^F}^.' ' l i� agg"gg a e 9 3 i q n asilli O -m. I ,9a ° Ii i! iE ■ pp i,i i J H e% yg iy it ° Il R _ 5s E Y 11$112171a @B` F 5 d i >6 ! lia �tl 03 R ¢tae ��-i:3 a i" . ' £ i 11511614 a1 0's§5 ` h II 6 R8 $ e /'1V 111 3`. z 1 q h ,1 `� � $$ a 3 � � � p gyp` s hi 3 o R a ��;� a y Gl iiilill g i R F6 18 G R ii . + 6 1 tl i5 `` M 3 FFk 1§i i 2 ; a gg 11 q § i i 0 I j : it g le g ' o ya.HMI 654 fpap( ggl t�K :(E00":11;:n0':7: § gIE "�";@@7 ', - - r-1 ,I6 f ; iIII !4 8C5 8 6 a I' �G .R 9i d a�• Y !El J �` i 6 r Y , rRdd�` d_ aw . . .i.,j :1:: 4tgtl ; ` ` ! A A Y pia i k1 9� i 0 i£ 1 s , to r 9 XA i E t !J/ : q,st .;rh. 11+;, , `si AT' ---H�L� __' _— - q r rr- L4 ei- �__ L gg AI 9 * r .ram C = i !e/ 1 ,1®b , ` ,1 ."�d 4.: ®t AIgoi,ip q,,,k, 1. 1, I iJr__ rr- itii,,-i�.. ���. I '+-._7 .._:. a 1,.yw _ 1 .JI 7 f'r kg.; ltz t,ay i '^+. if I :��.,,,,„...-,zip__ + .'I : �� ,� i7, -� .Y ' I ; /i!fir I i, Ftl.' %l l ar ftije i'f r i f� J l 12 /' It31`t 1 .�:�y`,� Jr ®$ rP!ll�r a7 r� y +Ir �`'�•�` �.. __�i I r �i I 11Ff d. '--�::\ `�`� r4 , + ,q ®� A ;[: f '+ • '' ,\. ®bpi,-�¢;`•+�1 �� �l r''.i;, '•rgrl kJ + ,r ItJ\ r�;. S `i I .. rdxr' / �1g a ? /�.' .�, fit, ® 0 9 ev I' 7` `;-',;,1",-- --,-irt°';'/,Z71.-„I'll,'-t9i L T„L 1illIf, a I J'® rV'I �1! „, 'J, 7 Jr W (®`` + g rU r'� `. cig � a9- `J/ r"®d3 aY (tr/ r ` Ix! I , . i I _ i.; ` `,` -'fY.'t a,> . iJ./ , +42 ,1 .i .' .a',+i ' I•f"."5' rs/,fir 11 r ryit ii, : LI , i . ; (�gg�I�� :C 1,�1• s `. a ,T is 4,; +fir, /k" Y'/�I ill 4444' is -- 21a+▪ ill `A�'r e- . s ` ` ' fir• �". ' 1.a1�r' �y�1�1 ili e_'' ' �i 7$` et f • (-r ,ram ®ar' ,!. \, R •.s %, l it 1;•yi �� : ft r `�/F^. _oki -...k, 1 :: >Y•� r 43 \Z. rI v . ( j +,'r ,,r O �I INai ,_ 'ig z54 e 1 c .,7- �-'iik---:kut ,Yr"„\ �y°S` >,y i•t . :.s / 1 M+r, Jr,t a' §r J" 6111 E y ii ` y _4 c, ' `w 4 , i �.• a i�C, sill\`yY'•,\Y. t. -/J //1 ,r Y` .�,9,r 4�: 9;"deg �. 11 f. -ram o (1 't '4` ' �. ,t\v. ! •111 1 it ,rin i / /� y 1!r 61 l ,�6?;1�Ii �+^V.I, ``\ ® •� › /� �-- 8a, 1 IL,l +l / I@ / r Z o.`• 4A, / �t''1�1 1 erye�a ti J ' liar ' 1 ,i E i��'. 1 UL._, I' W '� •Yy ram,,r w I I 1a +`I ` -l• �f 1 9 R€ gEgE I <�- J „I !-+ „1 \I 'i1+ _'i`-- �_ .• i .grip st 63 Ua i i i� i i . .., 1 II I , r q L 1P !1gdBBB �' ' ! J e 1=, , ___:_/ fC I 1 8= 3 ! -� j lI 1 S y9 i 5@ a { a t . EEyy K ggyy illi • m � +a J! 1 ! 1 4 III . o o M' e o e { i l } I I l 1.111 z t vxowanu.,.�iq a.a.,.v,ata,•sau:ua.nmw.m.xr M xarcc.C,d xaunae,.ua isoe 1 oa 1�3renc�xai.nau®a aC]an Y,pY.MIM1YWi ury wsl.oxa uwi.niNO.'M OIYYa 4 MYX.IId io.LLxa.atla D..1331N q:u.o aarxea88MtlIv�Iwaan,evxWgO xxaei.n. L �4'A Cp CATAWBA COUNTY 100A SOUTHWEST BLVD NEWTON,NORTH CAROLINA 28658 RECEIPT U� ��►� PHONE:828.465.8399 �4►� Wednesday,June 21, 2023 18 4 2 sM www.catawbacountync.gov PAYOR: Agri-Waste Technology Inc Agri-Waste Technology Inc(Moran,Jennifer) PAYMENTS TRANSACTION NUMBER: TRC-66813274-21-06-2023 PAYMENT DATE: 06/21/2023 PAYMENT TYPE: Credit Card 307016160 INVOICE NUMBER ACCOUNT FEE NAME FEE AMOUNT 06-23-424364 110-580200-663000 AOWE $135.00 TOTAL PAYMENTS: $135.00 RBPR-06-2023-44694 CASE TYPE: Residential Building Plan Review WORK CLASS: Building New SITE ADDRESS: CARDIFF CT,CATAWBA NC 28609 Applicant AGRI-WASTE TECHNOLOGY,INC.,, C:9193676313 Owner ADAMS HOMES AEC,LLC,3401 ST.VARDELL LN SUITE B,CHARLOTTE NC 28217 B:7045584527 BCASHION@ADAMSHOMES.COM Paid By AGRI-WASTE TECHNOLOGY INC,501 N SALEM ST SUITE 203,APEX NC 27502 B:9193676320 JMORAN@AGRIWASTE.COM **NO PEOPLESOFT ACCOUNT ASSIGNED** receipt 06/21/2023 10:45 Page 1 of 1