Loading...
HomeMy WebLinkAboutIMPV-06-2023-197345.tif Lot .2 County: Gu y-olba.. IMPROVEMENT PERMIT FOR G.S.130A-335(a2)/SL2022-11 PIN/Lot Identifier: L'1(p 0(a d3 co—4 r602 Issued To: i'Srn.rr. cobble. V't01101r/ Qcv, LL-(.. Property Location: LL 703q C*bit c-;-oldL ' I)G(\�-r Z sgo37 Subdivision: G C1�1V)GSCr+C. Lot#: -2 1 Block: Section: LSS Report Provided: Yes lig No 0 If yes,name and license number of LS5: rYrt.PC.` PI- VI%C.1 O\Wel rj 1231 New 1N Repair❑ Expansion 0 System Relocation 0 Proposed Structure: LI ¶Y c.. `ws0 t+ f'Icolrr+i ¢61ir)Cht.C.. Proposed Wastewater System Type: Ac1G(41'1$%, ICdtk., ?t\ (Initial) rec3Q5 10u) Pi"'C-3 . -C. (Repair) Fill System:❑Yes 6a No If yes,specify:0 New 0 Existing (when adding more than 6 inches of fill to system area please provide a fill plan) Proposed Design Daily Flow: Wg° GPD Proposed LIAR(Initial): 0,3 Proposed LIAR(Repair): O.j Design Wastewater Strength:A domestic 0 high strength 0 industrial process Number of bedrooms: M Number of Occupants: % Other: Pump Required: xYes 0 No 0 May be required based upon final location and elevations of facilities Artificial Drainage Required: 0 Yes ®No If yes,please specify details: Type of Water Supply:71 Private well 0 Public well 0 Municipal Supply 0 Spring 0 Other: Drainfield location meets requirements of Rule.1945: Yes® No❑ Drainfield location meets requirements of Rule,1950: Yes® No 0 Permit valid for: ain Five years(site plan submitted pursuant to GS 130A-334(13a)J 0 No expiration[plat submitted pursuant to GS 130A-334(7a)] Permit conditions: Soc.- dtS:n Licensed Soil Scientist Print Name: �aa. r cc l�S Licensed Soil Scientist Signature:�y �c�-u (7 // .c Date: `1/7/� The LSS evaluation is being submitted pursuant to and meets the requirements of G.S. 130A-335(a2). *See attached site sketch* • 7039 Cobblefield Ln I Lot 23 County: Catawba This Section for Local Health Department Use Only Initial submittal received:5/1/23 by RP Date initials Permit Number: IM PV-06-2023-197345 G.S. 130A-335(a4)states the following: 'If a local health department fails to act on an application for an improvement permit submitted pursuant to subsection 03)of the section within 10 business days of receipt of a complete application, the local health department shall issue the improvement permit.' In accordance with G.S. 130A-335(a3)the improvement permit application is: ❑ Incomplete(If box is checked, information in this section is required.) The following items are missing: Copies of this were sent to the LSS and the Owner on Dote State Authorized Agent: Date: ❑ Denied(See attached report.) Copies of this were sent to the LSS and the Owner on Date State Authorized Agent: Date: © Complete State Authorized Agent: Date of Issuance: 6/5/23 This Improvement Permit is issued pursuant to G.S. 130A-335(a2),(a3),and (a4)using the signed and sealed L55/LG evaluation(s) attached here. The issuance of this permit by the Health Department in no way guarantees the issuance of other permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements. This site is subject to revocation if the site plan,plat,or the intended use changes,or if information submitted in the application was falsified, inaccurate or misleading. The Improvement Permit shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to conditions of this permit. The location and identification of all property lines,easements,water lines,and other appropriate utilities shall be the responsibility of the owner. The Department,the Department's authorized agents,and the local health departments shall be discharged and released from any liabilities,duties,and responsibilities imposed by statute or in common law from any claim arising out of or attributed to evaluations,submittals,or actions from a licensed soil scientist or licensed geologist pursuant to GS 130A-335(a2). Improvement Permit Expiration Date: 6/5/28 *See attached site sketch* is 2- SOIL I FDRESTRY SERVICES OF THE CAf OLINA:5. PA www.soilandforestryservices.com Project#:21-0093 May 16t", 2023 Nest Homes Attn:Matt Varney Email: mvarney@nesthomes.corn RE: Soil &She Evaluation for a 4 Bedroom Residence at 7039 Cobblefield In, 1.01 at Parcel, PIN#460603128135,7039 Cobblefield In, Denver, NC 28037. Dear Matt Varney: At your request Soil &i-orestry Services of the Carolinas(S&FS) has performed soil/site evaluations on parcel noted above. The Lot size is noted on the attached survey map&soil evaluation form.The purpose of our work was to identify soil areas with potential to support subsurface wastewater disposal systems and provide design details for Session Law submittal to Catawba County Health Department. Site Conditions At the time of our evaluation land cover on the property was partially cleared and partially wooded. Topography within the evaluated area was gentle slope near the existing house site and proposed drainfield area, There is an existing septic and well that will need to be abandoned and a proposed new well(see Site Plan & Design with Applications). Property lines and corners were marked at the time of the evaluation by Don Alien and Associates Surveying. The surveyor provided an Autocad File of a survey as a basemap. The proposed septic layout was located via survey and used to produce the attached Site Plan.The existing site improvements (house, well, septic system,etc)was located via Survey by Don Allen and Associates Surveying. Methodology We evaluated soil areas through the use of back hoe pits.Soil morphological conditions including color, texture, structure, etc.were reviewed in the field with seven soil pits on the property flagged and located via survey. All of the soil pits are located in or adjacent to the proposed septic layout. Soil suitability was determined by referencing 1SA NCAC 18A.1900"Laws and Rules for Sewage Treatment and Disposal Systems". Soil&Site Evaluation Forms were utilized to record the soil morphological data for each boring.An on-ground layout of system and repair was performed using a laser level. Pin flag locations of the layout were also located by survey. Detailed system& repair information is summarized in the following paragraph for this Lot. • 7039 cobblefield In (See Attached Design) The septic layout for this lot (9' centers)yielded a total of 829 linear feet of line.The primary system is proposed as 400 linear feet of Accepted (25% Reduction)drainfield with pressure manifold distribution.Trench depth is specified at 30 inches(Low Side). The repair system is proposed as 267 linear feet of PPBPS(50%Reduction) drainfield with low pressure distribution.Trench depth is specified at 30 inches (Low Side).There is 429 linear feet available for repair. Primary and repair is located at 23A offsite easement. Session Law Requirements All information needed to issue the IP must be submitted with the application.The application shall include all information described in 15A NCAC 18A.1937(d) and be accompanied by a signed and dated statement from the applicant (owner or owner's legal representative)that reads as follows: "The LSS/LG evaluation(s)attached to this application is to be used to issue an improvement Permit in accordance with G.S. 130A-335(a2)and(a3)." Owner / Date '' Print Name ' -4-('`11Q� rtA.I ICI \C Signature ! 2. The LSS evaluation shall include a statement bearing the LSS seal and signature that reads as follows: "The LSS evaluation is being submitted pursuant to and meets the requirements of G.S. .I30A- 335(a2)." Disclaimer This report reflects the findings of S&FS, PA. This LSS evaluation is being submitted pursuant to and meets the requirements of G.S. 130A-335(a2)."Any site modifications that impact the proposed septic areas on 7039 cobblefield, Denver, NC 28037 may nullify this design.System design requirements and site requirements shall be adhered to for Installation and Operations Permits to be Issued by the local Health Department. If you have questions regarding these requirements a Pre-Construction meeting should be scheduled to discuss. Please contact S&FS if you have any questions regarding this report or the attached information. S&FS a • - 3c : • c system inspection,wetland delineation and forestry services. �0 S O�� �C Sincerely, L q. PO, ( � E iff—r /10 ider„. • •.-• 'V cow a' .401 .7AF O S.Ashley Rollans, LSS Op GR.� Attachment: Septic Design NORM • IFF SOIL & FORESTRY SERVICES rill- 7 I IL L:Ea1l[71 www.sollandforestr yservices.com Attached is a proposed design for an Accepted (25% reduction)Septic System with Pressure Manifold distribution for a 4 bedroom single family residence at 7039 Cobblefield La Subdivision Lot 23A,(PIN#:460603128135),Denver NC,28037. Contents: P- ut Information for the Installer — 1 Design Information Design Specifications- --------------- --------------• 2-3 Layout Specifications --------------- ---------_—_— -- 4 System Tapsheet -- ----- 5 Pressure Manifold Diagram ------------------------------__-- g Site Plan/System Plan --- -- —_-__ 7 Calculations — _____----------------------___-- 8 Profile Descriptions --- ---------- ------ 9-10 Subdivision Plat---- 11 Session Law Form — ------ -----_-_ 12 Application — -- SUBMITTED ***PROFEESIONAL ENGINEER REQUIRED TO PROVIDE DESIGN - SPECIFICATIONS FOR EXISTING FORCE MAINS PRIOR TO p kit .� ISSUANCE OF AUTHORIZATION TO CONSTRUCT. A. • �� Ar �y t March 17,2022 Project No.21-0093 � �•;,, ,� Design By: Soil& Forestry Services of the Carolinas,PA Igalp 1 INFORMATION FOR THE INSTALLER: - The permit should be read very carefully prior to bidding. The following are details that must be considered along with all other considerations. - Tanks shall be approved by DHHS, and certification supplied by the manufacturer. - Tanks shall be water tested prior to installation. - The installer shall be responsible to the owner for placement of the tanks and to insure that final grades are returned to the original natural grade, with exception of added structural features. - The supply trench shall be compacted to eliminate cavities left during initial fill placement. - Installation of the system shall be during dry conditions in order to protect the soil structure. - All fittings shall be pressure rated fittings. - All joints shall be cleaned with PVC pipe cleaner and a heavy bodied glue applied to weld all joints. - Trenches shall be carefully excavated so the bottom is within 2"from the highest to . the lowest points of elevation within the trench. If the bottom elevation needs adjusting after it has been trenched, it will be done by removing high points rather than filling low points. It is extremely important to insure that trenches are not over excavated during initial trenching. All fine grading within the trench will be hand done with a shovel. No loose material will be left in the trench - All pipe openings in the tanks shall be properly grouted. This also applies to the joints around the riser. - All tanks shall be properly back filled and compacted to prevent slump at a later date. - Earth dams, constructed of relatively impervious material, shall be installed at the beginning and end of each lateral. - No heavy equipment shall be used on the field during or after installation. The use of a small loader(i.e. Bobcat) or a trencher(i.e. Ditch Witch 2300/2310)may be used for installation. - Elevations at pinflag locations should be checked by the installer prior to beginning trenches. - Pumptank riser should be 6"above grade, control panel should be 12" above grade. - Septic tank riser shall be a minimum of 6" above finished grade. - System is specified as an Accepted 25%reduction installation w/Pressure Manifold. - Repair is specified as a PPBPS 50%reduction installation w/Low Pressure Distribution. - Rake trench walls, lime sidewalls, install trenches 36" wide and have no more than 1/4" fall in 10 feet. - Repair Supply line size,length and elevation head must be provided prior to AC - Repair is offsite on Lot 23A. Supply lines were installed per expired IP. • Layout Specifications - 7039 Cobblefield Ln - Lot23A Project#:21-0093 LAYOUT FOR 4 BEDROOM HOME March 17,2022 FLAG FLAGGED DESIGN LINE# COLOR 15 HI FS ELEVATION ,LINE LENGTH LINE LENGTH TBM 1.50 101.5 100.00 HOUSE PUMP TANK INSTR. 1 OFFSITE 23A I BLUE 1.40 100.10 79 79 2 PINK 2.70 98.80 44 44 3 ORANGE 2.70 98.80 85 85 4 BLUE 3.75 97.75 115 100 5 PINK 5.00 96.50 125 100 6 YELLOW 6.10 95.40 125 100 7 RED 6.70 94.80 108 100 8 ORANGE 7.90 93.60 I04 104 9 BLUE 9.20 92.30 44 44 Total 829 756 SOIL LOW SIDE LINE LIAR SYSTEM LTAR TRENCH TRENCH LENGTH GPD/FJ'2 TYPE GPD/FT2 SYSTEM DISTRIBUTION DEPTH *System: 400 0.300 ACCEPT. 0.300 25%RED PRESSURE 30" MANIFOLD Repair 429 0.300 MOD. 0.300 PPBPS LOW 30" Plus(15',25',25',8') CONY. PRESSURE on lines 4,5,6,7, Notes: **All measures in feet **Nitrification lines are demonstrated on contour via colored pin flags **Nitrification lines were located by GPS and Tape Measure. 5 PRESSURE MANIFOLD TAPSHEET - 7039 Cobblefield Lane-Lot 23A SYSTEM Lind aka Elsv,t n Len2lb Hole Sl 17owTFip Tnoch rct J,.ine LTAR 4 BLUE 97.75 100 SCH 40 112 7.11 300 0.15 5 PINK 96.50 ZOO SCf14o 1/2 7.11 300 0.15 6 YELLOW 95.40 100 SCli 40 1t2 7.11 300 0.15 7 RED 94.80 100 SCH 40 1/2 7.11 300 0.15 total teet = 400 gal/min- 28.44 Dn.Mow 480 Pump Ran= 6.43 soil LTAR 03 LTAR+5% 0315 LTAR with ACCEPTED 0.4 LTAR with ACCEPTED+5% 0.42 Dal i 11 \ s ,r r,... .,, SVO . 1 / 1! t • ', : s \ 11 AA 4C4)140 ... * I . 1 Ce. . \IS , 47#7 I& \el I 0 . "0440 - .,A, 4, '- 1 . - . 1 ;lei ________ \ it gi: ii \ 17 ka x ie • O- G,>�C' ' , ec PL9 0 co.6 .k ,C0 "J V o hs 4. © moo- sa O/12 4ir 0 •e ,� 4�•1 . 0:t.„ oet. , ,eu f% () too _, . -1 ,4 0 0 4e �� 0 , oC) . a c SCALE � `�' 0 1 " - 50 ' COC� fit 0 '‘.--ii ., C I) &,t) ' . ",/,, . ,,__. 1:,._.5\/ V '\., ,, .A CI o CO 44 CD ks c1.1 \,,,,,s li‘v' co 1,4,....ii CO q-,_ •,, .0 0.41 , 491 ipt �� �1 L0 f 0 .� o (:::5?, Q 6 `,..., z i c_c) qD : ;--\ ,2) ‘._ c, , ‘,„ ,_, vi‘ ..._)--- h ,'3 CA \/ v, 0) ko 4- o. o, P 7 \- I*r 1-1 k� L�` 111.44 77LL V,CLAYi '1?' 3 cb P6 ,` 6 G u deff /13C) , � I.3 ►, CF'S1 ti, � j\I 0 Do NDI P4 I </....---->„.„7 -x SCALF -e,),., .1 7 „, , 4'r „. : --- 30 (4 ii: 4 li! y4 E t Sheet_1. of 2. 2i4 - Ease nn,1 .-PROPERTY ID#:�R�_e COUNTY: W R SOIL/SITE EVALUATION for ON-SITE WASTEWATER SYSTEM A ' f (Complete all fields in full) OWNER: A)e34 N U-C _ APPLICATION DATE ADDRESS: (23(p va.tetk_ 'dr 54.4.;4t'tj rndtrtSv((it AK 02,1117 DATE EVALUATED: PROPOSED FACILITY: Li , PROPOSED DESIGN FI,OWf�.1949): r3C1 PROPERTY SIZE: r.(ol ACLOCATION OF SITE: r.?O39 �.tiak4iercl L►,awe, 44,4 a A} PROPERTY RECORDED: 141.S WATER SUPPLY: ❑Private 0 Public M"Well 0 Spring 0 Other EVALUATION METHOD: 0 Amer Boring PK 0 Cut TYPE OF WASTEWATER: !$Lwage ❑Industrial Process LI Mixed P 0 R SOIL MORPHOLOGY OTHER p (.1941) PROFILE FACTORS 1 .1940 L LANDSCAPE HORIZON POSITION/ DEPTH 1942 PROFILE s SLOPE 4% M••) .1941 .1941 SOIL .1943 .19S6 .1944 CLASS STRUCTURE/ CONSISTENCE/ WETNESS/ SOIL S.APR RESTR &LTAR TEXTURE MLNERAI.OGY COLOR DEPTH 0 HORIZ CLASS d - 7 MO s ✓ ress-f xr 7- 70 $itcw L N VF A vI 70 16 1 L.- ( 1\o _ 0f J -h 0 ` 1 13`71c� y -iS>f'4-Xt P7--- 6(6 124,,,,041Alok. 1.1 e ,s. t.: -f lik nt.,,, 618 - 2 t _ ( P..1, ': 1 - 5— /4 P oP Jf.k. I. H h H ` S _ 7, F s 0-(.t feCCV.Pis 05S? ta— It RAW —�c� rs ram+ ct �t 4 \a.1, 38" • as zeil sbit se . 1 DESCRIPTION INITIAL SYSTEM REPAIR SYSTEM i OTHER FACTORS(.1946):_ c ��� Available Space(.1945) �S �S SITE CLASSIFICATION(.194$): 1_��+��'' ' I•`•'•.;.,/1 19 EVALUATED BY: S AShlt Roi}1�s Vie`•.+��.` -may System Type(s) ACU D� Q PS OTHER(S)PRESENT: `ti'0aE' _ wore ';ti Site LTAR c). 3 O.3 / f,.; ''1 / �_ ,. . COMMENTS: _ ` _ — Updated February 2014 SOIL/SITE EVALUATION sheer_ of ^{ (Continuation sheet-fbmplete al field In full) \CY J PROPERTY ID#: 054 re DATE OF EVALUATION:—3`e.+COUNTY:_ _ • s s • P p SOIL MORPHOLOGY OTHER F (.I941) PROFILE FACTORS 1 .1940 LANDSCAPE .1942 HORIZPOSITION/ ON .1941 .1941 SOIL .1943 .1956 .1944 PROFILE e SLOPE% DEPTH STRUCTURE! CONSISTENCE! WETNESS! SOIL SAPRO RESTR CLASS O .I TEXTURE MINERALOGY COLOR DEPTH CLASS HORIZ &LTAR rt? 0 fiSYam ,,.\ tSiik4s . _ \4/4 q- SH .l wa•sa cyst ..S. cd / . o— S. as1 S-1d K 1 L I p, .�,, Gc \%) V3- vr3 sikc,,,JMAkAild, y tie , C' 7 I 1.j'5- ( 7 �ys�w�^.olGc , clasp -w`�m.%t o c d- 9� rs 1 1 si kr-111.4 tkir,svarri4014. qic44) COMMENTS: Updated February 2014 • PIEDMONT DESIGN ASSOCIATES, P.A. 125 East Plaza Drive I Suite#101 Engineering Mooresvilie, NC 28115 Surveying Phone: 704-664-7888 I Fax: 704-664-1778 Planning Email: dmunday@pdapa.com April 5, 2022 Catawba County Health Department PO Box 389 Newton, NC 28658 Attn: Robbie Phelps, REHS RE: Offsite Effluent Force Mains serving Lots 18-20 & Lots 23-25 Burris Road and Cobblefield Lane, Cobblestone Subdivision Catawba County, North Carolina Dear Mr. Phelps: ENGINEERS CERTIFICATION 1, Donald L. Munday, as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe periodically the construction of the referenced project, (6) Offsite Septic System Supply Lines to serve Lots 18 (18-A), 19 (19-A), 20 (20-A), 23 (23-A), 24 (24-A) & 25 (25-A) in Cobblestone Subdivision, located in Catawba County, NC, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the testing such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. Please note that this certification is NOT for the actual systems themselves but for the supply lines from the individual residence(s) to the offsite easement area(s) only. Sincerely, PIEDMONT DESIGN ASSOCIATES, P.A. C "`�C�� ' ,. ,1/ 2,1 - SEAL 17327 - Donald L. Munday, P.E. q,�„ ... N.C. Registration No. 17327 ��Crriiu '�, cc: Allen VanNoppen, Nest Homes 04/05/2022