HomeMy WebLinkAboutAUTH-06-2023-197491.TIF 1
la A
_N CATAWBA COUNTY' Case# AUf11-06-2023-197491
Q .t.II Public Health Department Subdivision
,,,(J Environmental I lealth Division PIN# 361804522134
PO Box 389.25 Gmenunent I)nvc.Newton.NC 28658 LOT# 1&2&3
/8 2 W
Site Address: 3889 ROCKY FORD RD, NEWTON NC 28658
Name on Permit: CATAWBA COUNTY
Property Size: Acres 110.8
Directions: St
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 100 g.p.d.
Type of Facility: Other-Landfill attendant building
Basement? No Basement Plumbing? No Bedrooms:
Water Supply: Private Well Maximum Occupants:
Soil LTAR: 03 g.p.d./ft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25%REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
Septic Tank: New Tank: 1,000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 252 sq ft Total Trench Length: 84 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 24 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 2 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
*Do not drive, grade, cut or fill over any part of the initial or repair septic areas.
*Install new 1000 gal septic tank and 84 feet of 25%reduction product according to manufacture specifications.
*All septic areas must remain 10 feet from property and water lines and 15 feet from building structure if
foundation drain is present.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: 0.3 d./ft2
9-P•
Proposed System: 25%REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
06 21 2023 09 2s