HomeMy WebLinkAboutAUTH-06-2023-197391.TIF tp � CATAWBA COUNTY Case H Mtl'I'l 1-04-2023-197391
j. Public Health Department Subdivision
i*,
'"ot s Environmental Health Division PIN# 371416942738
S
Apti w PO Box 389,25 Government Drive,Newton,NC 28658 LoT#
Site Address: 1630 33RD AVE NE,HICKORY NC 28601
Name on Permit 'HENSON CONSTRUCTION, INC.
Property Size: Acres 0.74
Directions: Springs Rd, Kool Park Rd, left 33rd Ave NE house on left, corner of 17th St NE
Owner/Authorized Representative Acknowledgement of Permit Receipt
Xcertify that I am the owner or authorized agent(owner's authorization required)representing the owner of
il
property described above.
s the property owner or authorized representative, I have received the above referenced
it(s)as requested in the application for service EHPR-03-2023-43668, by the following method(s):m :
Received in Person
Facsimile Transmittal(Return form with signature required)
r Electronic Image Transmittal/E-mail (Return receipt required)
s the property owner or authorized representative 1 have reviewed and understand the specific conditions
the permit issued, and further understand that all applicable regulatory requirements specified under the
i
North Carolina Laws and Rules for Sewage Treatment and Disposal Systems(15A NCAC I8A.1900),
and/or Well Construction Standards(15A NCAC 2C.0100), shall apply to the issuance of this permit and
the construction of the wastewater system and/or water supply well permitted.
Permit Issue Date:06/06/2023
Owner/Authorized Representative Signature 4
, Date 06/25/2023
Documentation of Permits)Transmittal
(permit transmitted by electronic or other means)
Permit transmitted by (name of person sending permit)
Signaturek-7Date/Time V b?1)3
Method: Fax Email US Mail Other
Owner's request to send by the above indicated method of transmittal in lieu of signature
We wantt tto hear from yoJAlease ttake a few momentts tto complette our custtomer service survey att
http://www.surveymonkey.com/s/EHCusttomerServlce
/ s, / bb; /dIcAd. 6w1
J,a 6I (, I � .5
chpennit 06✓07/2i)21 O6 46
-4-i1160) CATAWBACOUN'I'1' Case# AUII1-06-2023-1 973 9 1
t 1 Public Health Department Subdivision
"I Environmental Health Division PIN# 371416942738
PO Box 389,25 Government Drive.Newton,NC 28658 Ll)f#
8 2
Site Address: 1630 33RD AVE NE, HICKORY NC 28601
Name on Permit: *HENSON CONSTRUCTION, INC.
Property Size: Acres 0.74
Directions: Springs Rd, Kool Park Rd, left 33rd Ave NE house on left, corner of 17th St NE
Authorization to Construct Permit
Permit Category: Repairs Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence-
Basement? NO Basement Plumbing? No Bedrooms: 3
Water Supply: Public Water Maximum Occupants: 6
Soil LTAR: 0.275 g.p.d./ft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25% REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
Septic Tank: New Tank: 1.000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 990 sq ft Total Trench Length: 330 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 34 in
Minimum Soil Cover: 20 in Minimum Trench Separation: 6 ft on center
Number of Drain Lines: 7 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
*Do not drive. grade, cut or fill over any part of the septic system area.
*Existing septic tank MUST be properly abandoned (pumped, crushed and filled).
*Install new 1000 gal septic tank and 330 feet of 25%reduction product according to manufacture specifications
•
*Install septic with MAXIMUM trench depth of 34in.
*All septic system areas MUST remain 10 feet from property lines and 5 feet from building structure.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Not Required Soil LTAR: 9•P•d./ft2
Proposed System:
System Classification:
06 22 2(1 3 13.00