Loading...
HomeMy WebLinkAboutEHPR-06-2023-44496.TIF *ea THIS IS NOT A PERMIT Case# EHPR-06-2023-44496 CAIAWBA COUNTY I-IEAI:I'II DEPARTMENT 111,O PLAN REVIEW APPLICATION FOR ENVIRONMENTAL SERVICES t8 2 ski Envir 'ew-OSWP • IMPROVEMENT- EXPANSION T1111 23 Pv2v, 6 DefAenliy Applicant MAI'FI IEW AND MARISA ZIMMER, 122 CAMPANILE DRIVE,MOORESVILLE NC 28117 C:5168522768 MZIMMERI722O,GMAIL.COM Owner EVADENE SCRONCE,2198 W NC 10 I IWY,NEWTON NC 28658-7403 NAME TO APPEAR ON PERMIT Matthew and Marisa Zimmer SITE ADDRESS: 7358 WOODCHUCK RD,DENVER NC 28037 PIN# 460601372483 NAME of SUBDIVISION: CRESCENT LAND AND TIMBER CORP Lot N 69 Section/Block PROPERTY SIZE: Square Feet 28,749.60 Acres 0.66 DIRECTIONS: Hwy 16 S,left on Campground Rd,left on Catawba Burris Rd,right on Bankhead Rd,left on Woodchurck Rd,property on the right PRIMARY CONTACT: Applicant SEWER TYPE: Septic Tank GALLONS PER DAY: 480 WATER SUPPLY: Private Well DESCRIBE WORK: A2 IP only for a 4 bedroom,60x65 home. There is a current well that will be abandoned. The well is in the middle of the proposed house per Scott Kennedy with Michael Athanas and Associates. SITE INFORMATION Do any of the following apply to the property for which this application is applied? If the answer to any of the questions below is"YES',then supporting documentation is required: Does this site contain any jurisdictional wetlands? No Does this site contain any existing wastewater systems? Yes Is any of the wastewater going to be generated on the site other than domestic sewage? No Is the site subject to approval by any other public agency? No Are there any easements or right-of-ways on this property? No APPLICATION FOR: New Structure STRUCTURE TYPE: PRIMARY RESIDENCE FACILITY TYPE: House OTHER DESCRIPTION: DESCRIPTION OF mobile home will be torn down EXISTING STRUCTURES ON SITE(IF ANY) DIM EXISTING STRUCTURE: NUMBER OF EXISTING BEDROOMS: #OF OCCUPANTS: 8 PROPOSED CONSTRUCTION NEW STRUCTURE DIM:: 60x65 #OF NEW BEDROOMS:: 4 BASEMENT? Yes BASEMENT FIXTURES? No PLUMBING REQUIRED? EMPLOYEES PER SHIFT: NUMBER OF SHIFTS: TOTAL EMPLOYEES: SEATING CAPACITY: TOTAL FLOOR SPACE(SQ FT): Desired system types(Improvement Permit or Authorization to Construct): ACCEPTED: ALTERNATIVE: CONVENTIONAL: OTHER: INNOVATIVE: ANY: YES Other described: ellapp1R.ahi.n 07/06/2023 13:IS Page 1 of3 gobs.,„, Scale 1"=40' North 35 68' Connect B3 and R4 a this end. ` 7 Y ci et, . 82' " 11' /' 67' / 20 Existing 2-bedroom / 40' 58' •4� system. # 43' /4. i / o N Keep the tanks 10'from eI / house. I 63' 2140 ft2 :i AB#6 \ TDrip Repair '� ''' z E PT@23' Keep15'from 40.4 cut to lake. )A:,i *11454; _ Existing MH to be torn 1 43• _ �_ ..."% down. �� Niiiir 44; 56 ,. , HC@21.5 \ House box surveyed on � � , % the property. I 9 _\, — J �. Ne' bor's Well Propos ed 5 i Well O min Ie\ \ at A tiS :20.1.11.1. 38' \\ t 0' AB#5 i -�\� W1 'i 12' �PM@8.9 .4>4 . o. 26' \ 70' / \ SilkConnect W1 and 62 at / 296ft2 Drip Repair Area / this end. 111141011b' ' BM@1.1' c`-Q'a Line Design Length Actual Length Number of Panels Elevation V� •Q ,6� White 1 40' 40' 9 8.9' Blue 2 45' 45' 10 10' White Existing 50' 50' n/a 25.6' Blue 3 50' 53' 12 26.9' Red 4 35' 43' 8 27.9'