Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
IMPV-05-2023-196896.tif
County: Catawba IMPROVEMENT PERMIT FOR G.S.130A-335(a2)/SL2022-11 PIN/Lot Identifier: 462802558930 Issued To: Gus Sundermeier Property Location: 2715 Westview Dr. Subdivision: Lot#: 52 Block: Section: LSS Report Provided: Yes ✓❑ No 0 If yes,name and license number of LSS: Miranda Stamper New❑ Repair❑ Expansion ❑ System Relocation Q Proposed Structure: Pool Proposed Wastewater System Type: PPBPS (Initial) Pretreated TS2 Subsurface Drip Repair (Repair) Fill System:❑Yes ✓❑No If yes,specify:0 New ❑ Existing (when adding more than 6 inches of fill to system area please provide a fill plan) Proposed Design Daily Flow: 240 GPD Proposed LTAR(Initial): 0.3 Proposed LTAR(Repair): 0.1 Design Wastewater Strength:Q domestic ❑high strength 0 industrial process Number of bedrooms: 2 Number of Occupants: 4 max Other: Pump Required: 0 Yes ❑No ®May be required based upon final location and elevations of facilities Artificial Drainage Required: ❑Yes ❑✓ No If yes,please specify details: Type of Water Supply:Q Private well 0 Public well 0 Municipal Supply ❑Spring ❑Other: Drainfield location meets requirements of Rule.1945: Yes Q No 0 Drainfield location meets requirements of Rule.1950: Yes El No❑ Permit valid for:Q Five years[site plan submitted pursuant to GS 130A-334(13a)] ❑No expiration[plat submitted pursuant to GS 130A-334(7a)] Permit conditions: INFORMATION FOR INSTALLER:NEW SEPTIC TANK MUST HAVE ENOUGH FALL FROM EXISTING PLUMBING(INSTALL GRINDER IF NEEDED). ABANDON 57'FROM LINES 1 TO MEET SETBACKS FROM PROPOSED DECK FOUNDATIONS AND PROPOSED POOL. INSTALL 0-BOXES ON LINES 1&2 AND EXISTING SAND FROM FIRE PIT MUST BE REMOVED PRIOR TO INSTALLATION.USE SPOILS AS COVER FOR LINE 3 Licensed Soil Scientist Print Name: Miranda Stamper Miranda Stamp er Digitally signed by Miranda Stamper Licensed Soil Scientist Signature: Date:2023.02.07 13:00:59-05'00' Date: The LSS evaluation is being submitted pursuant to and meets the requirements of G.S.130A-335(a2). 'See attached site sketch* 2715 Westview Dr County: Catawba This Section for Local Health Department Use Only Initial submittal received: 3/9/23 by RP Date Initials Permit Number: IMPV-05-2023-196896 G.S. 130A-335(a4)states the following: 'If a local health department fails to act on an application for an improvement permit submitted pursuant to subsection(a3)of the section within 10 business days of receipt of a complete application, the local health department shall issue the improvement permit.' In accordance with G.S. 130A-335(a3)the improvement permit application is: ❑ Incomplete(If box is checked, information in this section is required.) The following items are missing: Copies of this were sent to the LSS and the Owner on Date State Authorized Agent: Date: ❑ Denied(See attached report.) Copies of this were sent to the LSS and the Owner on Date State Authorized Agent: Date: © Complete J�IA /i 5/30/23 State Authorized Agent: G I Date of Issuance: This Improvement Permit is issued pursuant to G.S.130A-335(a2), (a3),and(a4)using the signed and sealed LSS/LG evaluation(s) attached here. The issuance of this permit by the Health Department in no way guarantees the issuance of other permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements. This site is subject to revocation if the site plan,plat,or the intended use changes,or if information submitted in the application was falsified, inaccurate or misleading. The Improvement Permit shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to conditions of this permit. The location and identification of all property lines,easements,water lines,and other appropriate utilities shall be the responsibility of the owner. The Department,the Department's authorized agents,and the local health departments shall be discharged and released from any liabilities,duties,and responsibilities imposed by statute or in common law from any claim arising out of or attributed to evaluations,submittals,or actions from a licensed soil scientist or licensed geologist pursuant to GS 130A-335(a2). Improvement Permit Expiration Date: 5/30/28 *See attached site sketch* Z LINE SCHEDULE 2715 WESTVIEW DR,SHERRILLS FORD NC. SECTION-,LOT 52 LUTHER COWANS SHERRILL PROP LINE NUMBER COLOR FIELD ELEVATION LENGTH(FT) UtSI(iN LI NG I H (FT) 2-BEDROOM EXISTING CONVENTIONAL SYSTEM LINE 2&3 1 BLUE 27 10 8 PANEL BLOCK SYSTEM(HORIZONTAL)LINE 1&4 2 EXISTING 0 3.8 90 33 LINES 1-4 TOTAL 167 LINEAR FT LTAR 0.3 3 EXISTING Y 4.6 90 90 50% REDUCTION 8'OC 4 GREEN 6.2 36 36 20"MAX TRENCH BOTTOM(LOW SIDE) 5 BLUE 5.7 44 0 1-BEDROOM TS2 PRETREATED DRIP IRRIGATION 6 PINK 7.3 85 0 SYSTEM(AMERICAN PERC-RITE) RED 8.2 48 0 LINES 5-7 TOTAL 1200SQFT LTAR 0.1 TOTAL TOTAL 6"TRENCH BOTTOM 403 167 CONDITIONS: MUST BE INSTALLED BY A LICENSED SEPTIC INSTALLER. FOR GENERAL USE NOT A SURVEY DRAINFIELD AREA MUST MAINTAIN NATURAL CONTOURS&SLOPE. IMPROPER PRELIMINARY NOT FOR CONSTRUCTION OR EXCESSIVE GRADING WILL VOID THIS DESIGN AND BOSS IS NOT LIABLE. NOTES: SOIL NOTES PROVIDED BY MIRANDA INFORMATION FOR INSTALLER:NEW SEPTIC TANK MUST HAVE ENOUGH FALL STAMPER LSS#1258 FROM EXISTING PLUMBING(INSTALL GRINDER IF NEEDED). ABANDON 57'FROM LINE 2 TO MEET SETBACKS FROM PROPOSED DECK FOUNDATIONS AND LOT IS REPAIR EXEMPT PROPOSED POOL.INSTALL D-BOXES ON LINES 1-3 AND EXISTING SAND FROM FIRE PIT MUST BE REMOVED PRIOR TO INSTALLATION.USE SPOILS AS COVER FOR LINE 1&3 ADD LINE/PVC INITIAL LINE REPAIR LINE WESTVIEW DRIVE 60' R/W REMOVE LINE S 85'34'00"E W 95.00 I co O to GO Oa N O ~ NEW 5T 30' SIB C�C(E C7 z 1 _' _ _PORN oR E 53 2 PROPOSE A ° - x�sTxro SI �\ 3/ V 5 4 HOUSEEXISTING \\ 50' BUFFER-- �`(,' e0eo6 at > (� `� 0.464 AC.+— \ �0 30' BUFFER k\ .. ,, /. ��\ V., °vy4 / O� O� APPROX. FLOOD LINE \\ \\' c,� `L, 4,• 50 z \�Y \ I I 25 50 51 i o S \ \� SCALE: 1" = 50 ft. a'+ \ LOT 52 BOSS Benfield Outdoor Services&Solutions,LLC 2715 WESTVIEW DR, ,3, „�„°,,Rd, ,,,�,,,C 28117 P., „8 GUS SUNDERMEIER SHERRILLS FORD,NC mro�yeraeeyooesoom CATAWBA COUNTY . DATE01/20/23 DRAWNBY:MDB REVIEWIB)BY:AC • Slicer 1 ofI _ PROPERTY ID#: - COUNTY: SOIL/SITE EVALUATION for ON-SITE WASTEWATER SYSTEM (Complete all fields in full) OWNER: Gus Sundermeler Lot# 52 APPLICATION DATE: . ADDRESS:2715 west View Dr. DATE EVALUATED: 1/5/23 PROPOSED FACILITY: Pool PROPOSED DESIGN FLOW(.1949): 240 PROPERTY SIZE: 0.48 LOCATION OF SITE: PROPERTY RECORDI:I): WATER SUPPLY: 0 Private 0 Public 0 Well 0 Spring 0 Other EVALUATION METHOD: 0 Auger Boring 13 Pit 0 Cut TYPE OF WASTEWATER: 0 Sewage 0 Industrial Process 0 Mixed P I o SOIL MORPHOLOGY OTHER F (.1941) PROFILE FACTORS I .1940 F LANDSCAPE HORIZON - POSITION! DEPTH 1942 PROFILE # SLOPE% (IN.) .1941 .1941 SOIL .1943 CLASS.1956 .1944 STRUCTURE/ CONSISTENCE/ WETNESS! SOIL SAPRO RESTR &I.T4.R TEXTURE MINERALOGY COLOR DEPTH CLASS HORIZ B1 L 8% 0-9 SBK CL NEXP SS SP Fl 5YR 5/8 32" MANY 0.3 9-22 SBK C SEXP S P FI WITH INCLU COMMON - 22-32 SBK SCL NEXP SS SP FI 5YR 7/6 SIONS 32-48 SL MASS NEXP NS NP FI MOTTLES @32" @32 B2 L 8% 0-12 SBK CL NEXP S P Fl 5YR 4/6 20" MANY VERY DRIP 0.1 12-20 SBK C SEXP S P Fl PLASTIC INCLU AND 20-29 SBK C EXP S VP Fl SIONS EXPANSI VE 29-36 SBK CL NEXP S P FI @20" LAYER@ 20" P1 L 5-6% 0-5 GR SL NS NP FR 55" MANY 0.35 5-21 SBK C S SP Fl - INCLU - 21-27 SBK CL NS NP FR SIONS 27-55 WSBK CL NS NP FR @27" P2 L 5-6% 0-5 GR SL NS NP FR 48" 0.35 5-21 WSBK SCL NS NP FR - 21-25 SBK CL SS SP FI j 0 i L S .. r 25-48 SBK C S P FI t {� �f's \ a.E 40,04D:f ;i 4 ' C P\A dC't 4/)if I)ESCRITIO\ t\rll:u-s\-s-rxt REPAIR SYSTEM , OTHER FACTORS(.1946): la �' Pi C R,-r'{ Available Space(.1945) PS PS SITE CLASSIFICATION(.1948): System Type(s) PPBPS PRETREAT TB]SUBSURFACE OR 9+ EVALUATED BY: Miranda Stamper Site LTAR 0.3 0.1(AMER PERCRITE) OTHER(S)PRESENT: Michael Benfleld,Carlton Jones Cu\I\IE\TS: Updated March 2022 l-