Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RBPR-05-2023-44351.TIF
1 1 fi,E,PR-os .)o)3 -W3 I Esrirea' ROY COOPER•Governor NC DEPARTMENT OF KODY H.KINSLEY•Secretary _' - HEALTH AND HUMAN SERVICES HELEN WOLSTENHOLME•Interim Deputy Secretary for Health .ate„• '2° MARK T. BENTON•Assistant Secretary for Public Health Division of Public Health COMMON FORM FOR AUTHORIZED ON-SITE WASTEWATER EVALUATOR PERMIT OPTION FOR NON-ENGINEERED SYSTEMS See instructions for Use in Appendix A Except for"Date received",this Section to be completed by the AOWE in accordance with G.S.130A-336.2 LHD USE ONLY: Initial submittal of this NOI received: by Date Initials PART 1:Notice of Intent to Construct(NOI)-Please check all that apply ®Single System or ❑ Multiple Systems AND ®New ❑Expansion ❑ Relocation of all or part of the Existing System ❑ Relocation of Repair Area ❑ Repair—LHD Permit Number ❑Repair—EOP/LSS COVID 19/AOWE Permit Number 1. Facility Owner's name:(Owner,Company Name, Utility, Partnership, Individual, etc.): Adams Homes-AEC, LLC Mailing address: 3401 St. Vardell Lane, Suite B City:Charlotte State: NC Zip: 28217 Telephone number: 704-558-4527 E-mail Address: bcashion(a.adamshomes.com 2. Authorized On-Site Wastewater Evaluator(AOWE) name:Jeff Vaughan LSS License number:1227 AOWE Certification number:10003E Mailing address:501 N Salem St, Suite 203 City:Apex State: NC Zip:27502 Telephone number: 919-859-0669 E-mail Address: Ivauc1han(@,adriwaste.com 3. Licensed Geologist(LG)(if applicable) name: License Number: Mailing address: City: State: Zip: Telephone number: E-mail Address: 4. Proof of Errors and Omissions or other appropriate liability insurance for the following persons is attached that includes the name of the insurer, name of the insured and the effective dates of coverage: ®AOWE ❑ LG 5. Property location(physical address,tax parcel identification number or subdivision lot, block number of the property to be permitted Lot 68 Colchester Court, Catawba, NC. 28609 (Cardiff Glyn Subdivision) County Name: Catawba RECEIVED NC DEPARTMENT OF HEALTH AND HUMAN SERVICES • DIVISION OF PUBLIC HEALTH M AY 1 2 2023 LOCATION:5605 Six Forks Road,Raleigh,NC 27609 MAILING ADDRESS:1642 Mail Service Center,Raleigh,NC 27699-1642 www.ncdhhs.gov • TEL:919-707-5874 • FAX.919-845-3972 Environmental Health AN EQUAL OPPORTUNITY/AFFIRMATIVE ACTION EMPLOYER AOWE Common Form LHD Reference: 6. Type of facility: ® Place of residence No. Bedrooms:4 No.Occupants:8 ❑ Place of business Basis for flow calculation: ❑ Place of public assembly Basis for flow calculation: 7. Factors that would affect the wastewater load:domestic strength wastewater from a single-family residence 8. Type and location of proposed wastewater system: Pressure Manifold 25% Reduction Chamber drain field product. Location shown on site plan. 9. Design wastewater flow:480 gpd Design wastewater strength: ®domestic ❑ high strength ❑ industrial process(For high strength and industrial process wastewater,a Professional Engineer licensed in accordance with G.S.89C shall design the on-site wastewater system.) 10. A plat as defined in G.S. 130A-334(7a)is attached: ❑Yes ® No A site plan as defined in G.S. 130A-334(13a)is attached: I Yes ❑ No 11. Location of proposed or existing wells(drinking water,irrigation,geothermal,groundwater monitoring, sampling,etc.)and any potable and non-potable water conveyance lines is indicated on attached plans and complies with 15A NCAC 18A.1950: II Yes ❑ No This is a saprolite system. ❑Yes No 12, Evaluation(s)of soil conditions and site features in accordance with G.S. 130A-335(a1)signed and sealed by a LSS is attached: ®Yes ❑ No 13. Evaluation of geologic and hydrogeologic conditions signed and sealed by a LG is attached ❑Yes ® NA 14. Proposed landscape,site,drainage,or soil modifications are attached: ❑Yes ® NA Attestation by AOWE pursuant to G.S.130A-336.2 l Jeff Vaughan hereby attest that the information required to be included with Authorized On-Site Wastewater Evaluator(Print Name) this Notice of Intent to Construct is accurate and complete to the best of my knowledge and that the proposed system shall meet applicable federal,State,and local laws, regulations, rules and ordinances, and that the proposed system does not require a Professional Engineer, licensed in accordance with G.S.89C,and in accordance with 15A NCAC 18A.1938 and activities determined to be engineering as determined by the North Carolina Board of Examiners for Engineers and Surveyors. a .,/f �, e2'' , May 5, 2023 Signature of Authorized On-Site Wastewater Evaluator Date Owner self-submittal of NOI: hereby submit this NOI prepared by Print Name of Owner Print Name of Licensed PE pursuant to G.S. 130A-336.1. Signature of Owner Date DHHS/EHS/OSWP-AOWE COMMON FORM Updated April2022 Page 2 of 6 f AOWE Common Form LHD Reference: NOTES: LIABILITY: The Department,the Department's authorized agents,or local health departments shall have no liability for wastewater systems designed,constructed,and installed pursuant to an AOWE Permit Option IG.S.130A-336,2(f)] RIGHT OF ENTRY: The submittal of this Notice of Intent to Construct grants right of entry to the Local Health Department and the State to the referenced property. ISSUANCE OF BUILDING PERMIT: Once the LHD deems that the Notice of Intent to Construct is complete via signature in the section below,the owner may apply to the local permitting agency for a permit for electrical,plumbing,heating,air conditioning or other construction,location,or relocation activity under any provision of general or special law pursuant to G.S.130A-338. DHHS/EHS/OSWP—AOWE COMMON FORM Updated April2022 Page 3 of 6 r � AOWE Common Form LHD Reference: This section for Local Health Department use only. PART 2: LHD Completeness Review of the Notice of Intent to Construct "(c) Completeness Review for Notice of Intent to Construct.—The local health department shall determine whether the notice of intent to construct required pursuant to subsection(b)of this section is complete within five business days after receiving the notice of intent to construct.A determination of completeness means that the notice of intent to construct includes all of the required components.if the local health department determines that the notice of intent to construct is incomplete,the local health department shall notify the owner and list the information needed to complete the notice. The owner may then submit additional information to the local health department to cure the deficiencies in the initial notice.The local health department shall make a final determination as to whether the notice of intent to construct is complete within five business days after the department receives the additional information.If the local health department fails to act within any time period set out in this subsection,the owner may treat the failure to act as a determination of completeness. The owner shall be able to apply for the building permit for the project upon the decision of completeness of the notice of intent by the local health department or if the local health department fails to act within the five business day time period." The review for completeness of this Notice of Intent was conducted in accordance with G.S. 130A-336.2(c). This NOI is determined to be: ❑ INCOMPLETE(If box is checked,Information in this section is required.) Based upon review of information submitted in Part 1,the following items are missing: Copies of this form listing missing items were sent to the AOWE and the Owner on Date via with directions to re-submit missing items using Page 5 of this form. Email,FAX,USPS,hand-delivered Print Name of Authorized Agent of the LHD Signature of Authorized Agent of the LHD Date ❑ COMPLETE(If box is checked,information in this section is required.) Based upon review of information submitted in Part 1 of this form,this NOI is deemed COMPLETE. Copies of this signed form were sent to the AOWE and the Owner on via Date Email,FAX,USPS,hand-delivered A copy of this NO1 and tracking information was sent to the State on via Dote Email,FAX,USPS,hand-delivered Print Name of Authorized Agent of the LHD Signature of Authorized Agent of the LHD Date DHHS/EHS/OSWP—AOWE COMMON FORM Updated April2022 Page 4 of 6 AOWE Common Form LHD Reference: Re-submittal of NOI with missing items included This Section is for use by owner to submit items noted as missing during LHD Completeness Review above. Resubmittals must be accompanied by a cover letter from the AOWE. LHD USE ONLY: This NOI resubmittal received: by Date Initials Item#from initial NOI Resubmittal description Attestation by AOWE certified in North Carolina pursuant to G.S.130A-336.2 hereby attest that the information required to be included with Authorized On-Site Wastewater Evaluator(Print Name) this Notice of Intent to Construct is accurate and complete to the best of my knowledge and that the proposed system shall meet applicable federal,State,and local laws, regulations, rules,and ordinances. Signature of Authorized On-Site Wastewater Evaluator Dote The section below is for Local Health Deportment use after submittal of items noted as missing above. LHD Follow-up Completeness Review of Notice of Intent to Construct This follow-up review for completeness of this Notice and Intent was conducted in accordance with G.S. 130A- 336.2(c). This NOI is determined to be: ❑ INCOMPLETE Based upon review of information submitted in the RESUBMITTAL above,this Notice of Intent remains INCOMPETE because the following items from Part 1 of this form remain missing: Copies of this signed form were sent to the AOWE and the Owner on via Date Email,FAX,USPS,Hand-delivered Print name of authorized Agent of the LHD Signature of authorized Agent of the LHD Date ❑ COMPLETE Based upon review of information submitted in the RESUBMITTAL above in addition to information provided in Part 1 of this form,this NOI is deemed complete. Copies of this signed form were sent to the AOWE and the Owner on via Date Email,FAX,USPS,Hand-delivered A complete copy of this form with tracking information was sent to the State: via Date Email,FAX,USPS,hand-delivered Print name of authorized Agent of the LHD Signature of authorized Agent of the LHD Date DHHS/EH5/OSWP—AOWE COMMON FORM Updated April 2022 Page 5 of 6 AOWE Common Form LHD Reference: PART 3: Authorization to Operate(ATO) Except for date received,the Section below is to be completed by the Owner. LHD USE ONLY: Initial submittal of request for ATO received: by Date Initials Date of Post-construction Conference: T The following items are included in this submittal for an Authorization to Operate under an AOWE permit: 1. Signed and sealed copy of the AOWE's report that includes the information in G.S. 130A-336.2(k) ❑ Yes ❑ No 2. Operation and management program ❑ Yes ❑ No 3. Fee (as applicable) ❑ Yes ❑ No 4. Notarized letter documenting Owner's acceptance of the system from the AOWE ❑ Yes ❑ No 5. On-site Wastewater Contractor name: License number: Mailing address: City: State: Zip:_ Telephone number: E-mail Address: 6. Proof of Errors and Omissions or other appropriate liability insurance for the On-site Wastewater Contractor is attached and includes the name of the insurer, name of the insured,and the effective dates of coverage. ❑Yes ❑ No Attestation by the Owner for Authorization to Operate hereby attest that all items indicated above have been provided to the Print name of Owner County LHD and the system shall meet applicable federal,State, and local laws, regulations,rules,and ordinances. Signature of Owner Date This section for LHD Use Only. LHD Review of required information for the ATO ❑ INCOMPLETE Based upon review of information submitted in the Section above,the following items are missing from the information required for an Authorization to Operate for an AOWE permit: Copies of this signed form were sent to the AOWE and the Owner on via Date Email,FAX,USPS,Hand-delivered Print name of authorized Agent of the LHD Signature of authorized Agent of the LHD Date ❑ COMPLETE Based upon review of information submitted in the Section above,this Authorization to Operate is hereby issued in accordance with G.S. 130A-336.2(m). A copy of this complete NOI/ATO with tracking information was sent to the State on via Date Email,FAX,USPS,Hand-delivered Print name of authorized Agent of the LHD Signature of authorized Agent of the LHD Date ISSUANCE OF CERTIFICATE OF OCCUPANCY: Once the LHD determines completeness based upon the ATO submission,the owner may apply to the focal permitting agency for permanent electrical service to a residence,place of business or place of public assembly pursuant to G.S.130A-339. DIHS/EHS/OSWP—AOWE COMMON FORM Updated April 2022 Page 6 of 6 ..�' AGRITEC-01 GKROHL ,d► oRE7Y CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDDYYY) 3/14/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). CONTACT Connie Garkalns PRODUCER NAME: — Hartsfield&Nash Agency,Inc. PHONE (NC,No,Eut):(919)556-3698 (A/c,No):(919)556-8758 10405 Ligon Mill Rd.,Ste H Wake Forest,NC 27587 Ri�"DREss:Connle@hartsfield-nash.com INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:Selective Insurance Company of the Southeast 39926 INSURED INSURER B:ACCIDENT FUND INSURANCE COMPANY OF AMERICA 10166 Agri-Waste Technology Inc INSURER C:Evanston Insurance Company 501 N.Salem St Ste 203 INSURER D Apex,NC 27502 INSURERS: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR 1ADDL SUBR POLICY W EFF I POLICY EXP LIMITS LTR TYPE OF INSURANCE INSD VD POLICY NUMBER IMMIDDIYYYYI (MM/DDIYYYY) A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2,000,000 CLAIMS-MADE X OCCUR S 2253659 1/18/2023 1/18/2024 PREM SES lEa occur ence) $ 300,000 MED EXP(Any one person) $ 10,000 PERSONAL&ADV INJURY $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 4,000,000 POLICY X JELPf LOC PRODUCTS-COMP/OPAGG $ 4,000,000 OTHER: $ A AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT 1,000,000 (Ea accident) $ X ANY AUTO S 2253659 1/18/2023 1/18/2024 BODILY INJURY(Per person) $ OWNED ONLY AUUTNOOSyUyLED BODILYO INJURYp (Per accident) $ AURTOS ONLY _ AUTOS ON (( or accident)AMAGE $ $ A X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 2,000,000 EXCESS UAB CLAIMS-MADE S 2253659 1/18/2023 1/18/2024 AGGREGATE $ 2,000,000 DED RETENTION$ $ B AND EMPLOYRKERS LIAR I ON X STATUTE ERH YIN 100003072 1/18/2023 1/18/2024 1,000,000 ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ FFICER/MEMBER EXCLUDED? N NIA 1,000,000 (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ Byes,describe under E.L.DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS below C Prof&Pollution MKLV3ENV103400 8/22/2022 8/22/2023 Each Claim 5,000,000 A Leased/Rented S 2253659 1/18/2023 1/18/2024 Equipment 25,000 DESCRIPTION OF OPERATIONS!LOCATIONS!VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ***This is ONLY For Informational Purposes ACCORDANCE WITH THE POLICY PROVISIONS. Contact Agency for Specific Holder info to be added **** AUTHORIZED REPRESENTATIVE AUK.Kr6i4 ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD \\\ttltlilE: AI A/I I• Engineers and Soil ScientistsCeViE Agri-Waste Technology, Inc. 501 N Salem Street. Suite 203,Apex, NC 27502 "" agriwaste.com I 919.859.0669 Soil Suitability for Domestic Sewage Treatment and Disposal Systems Lot 68 Colchester Court, Catawba,NC. 28609 Cardiff Glyn Subdivision (Catawba County) PREPARED FOR: Adams Homes—AEC, LLC, Client PREPARED BY: Jeff Vaughan, Senior Agronomist& Soil Scientist Trevor Hackney,Environmental Scientist DATE: May 5, 2023 Soil suitability for domestic sewage treatment and disposal systems was evaluated on August 9, 2022, for the proposed property located at Lot 68 Colchester Court, Catawba, NC. Jeff Vaughan and Trevor Hackney of Agri-Waste Technology, Inc. (AWT) conducted the soil evaluation. This evaluation was done to facilitate permitting for a septic system. This report and attached documents were prepared to meet the requirements for an Authorized On-Site Wastewater Evaluator to meet G.S. 130A-336.2 A drawing of the site plan, septic layout, and boring locations is included in Attachment 1. Profile descriptions for each boring are included in Attachment 2. Additional documentation about the property is included in Attachment 3. This property is a subdivision of a larger property that will make up the Cardiff Glyn subdivision. This property area is approximately 0.93 acres. The property is an open grass field. The home is proposed on the low side of the property;the septic system is proposed upslope of the home. The proposed septic system is a pressure manifold septic system utilizing a 25%reduction chamber product. Soil Suitability for Domestic Sewage Treatment and Disposal Systems The drawing in Attachment 1 details the property boundaries (as proposed by Frank Craig), soil boring locations, and layout of drain field trenches (Completed by AWT). Four soil borings were assessed on the property. Soil borings were examined to determine soil suitability for on-site sewage disposal systems in accordance with 15A 18A .1900 Rules for Sewage Treatment and Disposal Systems. These borings were advanced with a hand auger. All soil borings are usable for a pressure manifold septic 1 system with a 25%reduction chamber product and are being utilized for the drain field area. A septic layout was performed to demonstrate available space (.1945). The layout in Attachment 1 indicates there is available space for a four-bedroom primary and repair system utilizing a 25%reduction chamber drain field product. The proposed LTAR(Long Term Acceptance Rate) by AWT is 0.3 GPD/ft2. The soils on this property are group IV soils within the distribution and treatment zone as used to define the LTAR. Since usable slope corrected soil depths meet or exceed 30"AWT is recommending the use of the 25% reduction chamber product. With an LTAR of 0.3 GPD/ft2, 800 linear feet of trench are necessary to support a four-bedroom home initial system. The maximum trench bottom should not exceed 18". The attached drawing proves that 400 linear feet of trench can be installed for the primary septic system. With this style trench 400 linear feet of trench are necessary to support a four-bedroom repair system. The attached drawing proves that 402 linear feet of trench can be installed for the repair system. Any disturbances or grading done in the usable area or within the proposed setbacks will change the potential of using the area designated for a drain field. We appreciate the opportunity to assist you in this matter. Please contact us with any questions, concerns, or comments. Sincerely, Jeff Vaughan, AOWE 2 Attachment 1: Site Plan/Drawing and Calculations . 51 1 lj �, - J 3 0111 ; 3 5 ;� I —1Ir1 i V1J 7Vi :a�' N Q. o a) . } B 17.0 __IN TZ �,..'Q • > a) nE to ill 0 c -,e ).. o ° o •L a) a) a) x 'N Ua_ Ua. cc ❑ ❑ w ��odo i— / N _�P , N co V to CO I� co a) a) w a) a) a) a) a) L L L L L L L L L CO U) U) U) U) U) cnUU) a) N N N C CO o CO O co m E C L O a)) O U a N •,-`'.,C a) co U o cn CO J W w en ac) c) Uj "0 a) U C ti O U) N X 7 Tr 3- To- CC) co Q Cl)J N CON 2 N Li_ a) E N c 7 N c ,- N a) N CO J CO E M 0 U) O O) O O Q CU SD _ _ 2 Er)a) to co r` U c CD m a U N c co = co F- E N- co 0) -a ❑ o O M E C6 Z In CU CO 2 CO O N N O r -C a) CO c Z I In ' ' 2 U o ° > rn N- _J r` u CU 0 rn r) ca co ` m ca N co i C oo c = co cD co U) Z cn CO tL N ei)i i- _0 _0 r` cn (n O iO O (0 co co Z c0 N O N L 1 u) U U a. < � (..) ti Jo -°i 0 rn Q o Q rn rn in ci U z J c O c _co .a) o L c Z LL o > o 0 U 0 0 -I 5 C.5 U N a) a) a) a) Q O O O` O a`. a. a. .s o N 51 1 I I- a lifi Ili i 0 .5 C w g 1,,§ i ,n ppl, 8- �� M„£V,6Se0S M„8£.90006 ,VE•OE ,LO'Z6 I • • SZ04 At!: ►. _1jr: m N 25 co co Q 0 �r �'zS a r, I 9zoL L_- -----—ecdind 61- - I____!_- SL Pai 8�t\ I 9 •EL el!4M' . bZOL :21.............................1 � '� //'t!q -- 1/II.,..., o g .I zzoL e1� dgg I -�` ZS �'i i I . ate/ I I �/ a�� '/ I- •• N>�' / I / �NQ/-- ! i� %/ I BLDL M /�'" rr 11J II I z .�./_• r o 4- !r 1 CM g 0 r „....f I ° 1 1 m clot/ 1 ,1 1� cl C I 1 1 1 Im VIOL 11 / — O =j It, 1 /! °91aS atlo�sap�S.SL I ?Lot. I ;� I �$ \s I� `~ N N I� oy N -. E R o a / m a GYi m .92 Q C L • 2-0 L o w; b o ui m . 2 . > o aa -- Q.— J soot .00 m IS v ,9ZELl m c g r. co c m ct 1N/l00 aj1S3H�100 ° €— - f0�� � �� a. -� obo- _ br " CI-:: LLN WV el _ J 5 v i gi .gkig MS T/ OM IIIII MI MI NM 1114p Ill44 J�J J� J Cl) coy�J '_- J�J Cl. I U 1 i, _______________ 1 i1 „i ----,. . p, 0'1 „ I, I ', I, I 1! I I 0 1; A ,, LL I 1 w,! SI 01 I! J o sr o 77 1 0 E o U • 6~L E Y yc d y3 0 U U >YTL ` s i 4 L 0 Na d 3 - GO w O O-0LOU O o O N u O COC V >C p- o O = c o> O o ocon I o E o o co c x_ v a IL0c O '-NO_ an• .6« N .`.0 —0U wL.a a LO yOC • Oy Q R V mvrn o o ,- o O_ 1iU - c7.a2 _ r "- ,N ° Eovv,oLN215Aaov000nES >,01, � c1� _• ..: ( >: > :N4N Lm. > c� m _ o t��ool •ovai $ oFo >,8 o-�_>, c-°avNmv -,o� oErnE ° EacLCoer ` oLuav0o° owr .°., 0c o.b ..rmo. avu e.y, • - wvrq>enaoovE2=`-EYV3� ooa`: 565ENm c.; .i c ^ W CV rn ��`n � ci � �o � c W � � ' YUJ G . � RY as a a c x c oii c omoa > y � - d o U � u > m _ c 2o � �' moNe wEnliov UU Ww IL dduu!u) u)Oa Uu. ui2i-m1 (-) (..) ww u_ aacncnCI) 1 III E9 1141 1iflt EOisi8U ia & a flx ,1Ii M„£b,6MS ,4£'0£ N _------ :7 a I — N N CO OD r _ L Q O O O ci p o— l H _ _ I p b O O O 'I' u- o 0 o c d 3 I E v v v v aN �r_Jr—� \\\ Lio U1 Nl Vf AN .... a. W i J Iiii CO CO CO CO j i H _ _ _ = a .......... ./• I''- I 0. 000C) 2 •,.� i i i ~ u) u) u) u) 9- /__. — I I C C C C o _ _ / ii co L 04 • L L4(/ / o ii 98 ./ • % W 0 0 CD h_le, v+ V c q0 � //!I / tQ./ ! o ; /' ^?% J F- _b `o o, a,3 m /./ // 1 e > iJ1 5 j /. LLc� a / / ! 1 - 7 / � X / o ` 00 - (! N Z a) / a Z / lon m , .-I N rn v / E ILI ° ! Z o (5- - U > a. N ,E. c C O v E . Y up -at- a) W . O v y- . 0 .z C N y A WO Dw C 0° VS`Cg vW O OO np-07 O V "_ as D, C V DW .N N nO ODOW ° y C Of. ODi = E WDE ' "- .E-o c vwNv=- ° a ° 7 -W ° O_-c D D - W v W C a) ° •p "O y In w _N U N W O7 A ° WLnOO !IDy 1 C 0 (0 co •C � m -yv= aN 0 2W .a ° 0=L N'. va' ` d o E sm -1' c • yN N 3 a ' ° W D N O Vl NW L D.5D Za- Li) ),d. N 2W °LNaEW _,,N ° . ] NN W- U2NI v a` D . `A uOEc•c = T OWV ' N C CC E„ a5i > ° ici NN2 w; WWc > s- c _c N ccvvo � O -0a E J Cy -- O ° aVy• _ N OO `�.O ' On TO70 N;O occLL.LLo_ WDOOOOE ° ° °« iE DOV OWNy ... W c C n H O O a D w L N i(n D I III 1 I .. 0__ . J -aE- 35 x I C) ii idol '1' Eb tOp 41111141 My£4,69,05 £'0£ is 1 o ir._-.--- .-----_ _ _'",.> 1 al!UM 46T' ' ,'o:,,, 1 ` __ ,8L �,\ 1 I 1�1 1 nl4 1'�.` 1�i ,,11 1 c0000000 1�f-, , M- �--- ,Z8 a!dind 61 I J _ f I� 0 f-• Is- 0 _._. /�' 1 1 I O _ LL e 8 o 8 8 o Q �.�� 9L Pa�81 \ i 0 0 0 0 0 Ur` \.•� I a 1 a va V7 inu; ul N j ff/ _ J 0 o i�r 8 $ $ $ 8 ~ a __ a �-- 2 x x 2 x r'Z8 a!dind 91 './ S N .r' I :L c c c c c aaNNa i' I y'I.41 E CON CO N m COtom �' d ro 0 �� , i E v _ 1 a. to __.� 7 �— / 4 _1 / / 11 I io 7. 0 •'S !O /.� /., "11, 75-E 0 V. • E. o ii � mo � � a�,nnoa, • 33• a I I 4® o 0 > a c a E as yl a. yo 0 QJ `7 V O N= t LO 2 2 0 .c o o a >w3 omo 0 0 co '0«La. m o� o o o u o •c Tv � [� a o O,L C V ; O N N U LO O .O N L o ( a y C o 15E_ t2Eo o� a .- oo c m;=vx_ oa 15. 7 N O 1] u Y o '� C a, N "O C -5 u, P.N s _u) U a, N O O L n O y N a • IA a a' f9'@ N C Q !O N N--O= a o o a, a 'O 0 _ O=.0 •.0 . N N N o o ' Cl a . '- C mho ; Ev L Noo o c • E -c� Z mc >� m N a, N v m awa � aL1) .n c t E 'n ,°nv, o, nLE- v� W n � � a1i 2 a E-c o m nE o ~ ^— o m ' v >-2•' O o o 4' 1 aim ai nN c o o 2 m a ov•o o E Tao m u c m ' c c c N !P. L E • VI C ry y c u7 _ (n� y �.-v C D O > 0 > U ,c: N y V N d C > C N J C C C •6"O N oo0 O� °yo c >6 a,,Na, O— EcooEvodoof m'm'm � � a� .o o yL" 5 . ot,�°2 -. ° oL a`ao�', `oaaT0 jo� N#o ... �� � i� � a u a ` `a E cnE gE E 'o N.o 013— .0 aci o N a.c a, a_. a..oi o, u w m 0 „, —vast->-mo,aoovE �.- E�co• I- 0o¢o4'. u° nEm i - N Mj d' O tD r i g%g ;l iJØll; tell L 1 t iI U r C i a .o „0., soO o 2 �` O•- ° .` 7 c'a O N C .0. � ' I v m E° as c > E p T. aFea 'o , 7 o w con °ip; 0 9 c O CR in c N pN 0 Y 0'' .O « 9 Z N 9 yy = V_ - 0 o C 0 — ECS iO O C O O R O i IR � " E �v ° � °x� rnN v , u bb-sue Eo o yc"- cps �o v y c o @� s d E o c a•• - .X m •o a l'i i e q N oa c N= - c °ci .0 o 0 0 c Y RR5 ¢N c c as v E c ` y .I w ° E.o aoi c E iln!,igg s§glinD 64111-N•il' 22 °o a ° ° s E .n hill 1 1 h 1 1 W g u) v v o ° E m o 'er co o. ° m as °1 3 a C I E m 3 v v o c ° C o c`p5 c eu -a' C. a" C o m•m o>" o .0 0 -. O p O fi G 1s. .'L 0— O OCo °�.aU ° °u 2 m O .3 0'` V —0 o m , m - .11 c C C C V •V1� L0hIn i , IM1 moE a 1n° a c) jlih L w° t Nft .c '_ >. _ O ° O C C t• ° tv o os E 43 °c .�.1 ° sop C P s) p - W ato 0 E e- n• 0 o Qa o N v 7 a' .0 ;% S S V . 2- aN O v O a p N N ° c O 0 N Oo .° ° — mo L u 7 ` iv .O C u C p — o . O O U 7 ° p M y wC a. O Orn` cf., N >. °a 52 U E z ' o ° w 0 E c a 0 e d c o� ° sh E E0° u H a Vc u .2E > o > oa o o E. z5° ° a0 _ V O y y aC jg ` t o Y ° oa a -.0 Cp 10.0Ct o —y H Z O° 9 L 1] O N ° N T O C C J Z: i i. 0 0 C y ° L N O a O V '42N ..0 . - ` C` : 2 to 2 .a m O >• d 2 r o n a 2 1puy :_ - ® ,.� 8 °°' U p F 0 0 ,`o, o d 0 v c D D ee-�e -a c: o E 'r rn rno o '' sC a w a c-• c c m c p 8Sg �; �a o�, w o� on o — —� o.. i 333 o g� ' $ I w o6 to U._ U m u a a s p F- y . 1 li d gg 4 i.1 �{ 5 0 x i i i j 41 . Z. N M an 1G h °D °i O 5 $a �° . i .Y li 773 i° . {l?,� Pi ¢d$d{l-zl gi0; i_'�dsi11I iostlii «. E -7-.7.TTgiFA N NN Y p.. gR d � a aP Fl. 51111 :Is 1 yaAi L 1 111 li 1111! !!!ii I 11893 8 F Y �n F w I 'uy i 1. o OC O° I— ; i= rkg sm i . E >: o N2 on ° $ O .— a for N °w o . a cn �Lon 0 o 1I:! t" 1 l U t c 't .5,'' xw oH .ilr i � wz ° gu 4 .72 it.t U '1= e ta u=oaw.xgt- U a o I yjjQQtt s . tk =3i c�.w'Js at b� �Qiill 1 11 .II II. — _-€ —II11 ICIY / `Is1, \\% C\\ aui\,„ ( r NLr�:�e�I' _ smgEIE 1 y.ig" �'� $-fro I — INail •. ^°µ °vJig la IT'lAA D. ,.�•.TT r2.. !YY N it! ! ! fel •`': ill i ii 11 1� g hi =n E. • fit\\<,114\_,\S 1.,,,,t-c\\ \\ ::::::: I sil in Ili ir 11....,_,,r„,21 , :kf ml ::!I uI \ ;o$__0 � r . ! a, 1 .. ' Z" / "` Oa_ g g I w gg F= g; :i pi 1111 i .1, • .1.-- i i t $ �' r ft1 Yill u c G o 6 it�t ill!: g) ', i \\\\� %\\\ 1\. .' jj{Illll°llwtl®I�11� I. A. 11I ;I—Iit 1 �I �I . `'' a L � 31 �1 81 O O . 51111 b i l� �1� g��� Li— m O 1 � I iVi 1 iii IthilIlil 7L I h 9t ye i ifi 2 { 5 �iaii iiil5 6dee iii ii°L >I .. I fl It it gliv1/1111 1 0 11 f - i ,I I li ill Bill 1111'4 IV lil 6 - �' as ' i, iliA2 1g a s ¢aA°Ia56f 41;lia Ire 1111:g IIiii i i g t j@ zti 7 e g a ° �'�g Eft ' i.if 3g f g qi 0 - 1 . I � I m . 1 m / 6 ii n 5p R ;48% Eg t r ➢ a G 6aF: L @ a 2 7 ill 11 ? ° I E n -i C '�S, e D pp hi a a 3 y g 1b n gp B ii lti 1 ei▪ E R sbo i a C aD, H Oil I . p;1 d ll i Psi iiii 1 li, 1 aI 14; ly Ili IIL I! x€yy §iij t:° 111 ! E n 1'i nll iblil T 2Slit ! E It § t Y i i 's 1 3p pa W1Illui IL EE, ml' JI - t , i f sttq H1k11limt a pit 11x s (U li IgIV'41 n ill Ijf`1II!IpPI'5xhh ill I k i li Al 1 Al 1 D 4 'l5n-Yg. _■ $ / a }u yr` e $1; n C ; i kKk ` e D A VI 1 If¢ f r 3 f fl to % gg f 6l 1. . �j 6 E S 3 1 n f e i 55 a pp 2a�l9 Ye s i t 9 S 1 ; a ; dl i I 2I 11 Ili a Z @ a L1ifl 391f11141 S ' t 4 8 l W a 7 % W li i5 g it , 11f s €gl_€L x I!! : i t lilt Vs i'l r Q P w 11 0� �I; 1� V fig i �� x p l iiEaysea °f� Rw p i 5 SBSSs Ii1F- f t ge I e� S .p 14 R n .� vgl - �li ���//////;Is 4 y3 �5alq / e.11e 3 ' ! yY 3 I a " .a t S ! t 1r• r1 1 i °1111' 11 111111 il k il'iiii ;l/!„ilt� 1 s1Lyn ▪E;81IEPt, in.41es=- = k' 2 i_ �- $=.3_.` rpm p � a as R .IP 0 tie 9 11 1 ;i ° y4, • b €1 1 li s pa gE 9pd F3 7 ; 8 i D 3 E I lh lIt a a° 1 $1`11; tiil ii45e9i r' i ft n g ��' 111 i i $l q 3`E II €it s $ 1 ill s P 1,, 1,% cv $t f e ell lei 11 iii4 111 iifiii 5j ; I1. I€ $ ai 2$ $5 Q°� a. a ° k �g(aieij $P ex i11 y i4 tr- LAB;1, g 1 ig S 1 Ys iiii Sdi"G F§ C' C a9 a92 lip 20 34 11 Zil !i a 0! 2a $ icy 4§ Il't€i22t�Iiiiiii 1 a f1 - ISI Gil II aI ▪ ##F l ggf� g g l j si f V all Septic System Design - Summary Page Project: Cardiff Glyn- Lot 68 Date: 4/24/2023 Property: 5064 Throneburg Rd Catawba, NC 28609 County: Catawba Engineers and Soil Scientists Subdiv.: Cardiff Glyn Agri-Waste Technology,Inc. Lot#: 68 Permit#: Project Manager: Owner: Adams Homes-AEC, LLC Jeff Vaughan, PhD, LSS Address: 3401 St.Vardell Lane,Suite B Type of System: III bg jvaughan@agriwaste.com Charlotte, NC 28217 919-859-0669 Phone: 704-558-4527 Engineer: Email: bcashion@adamshomes.com PIN: 378003016801 Rodney L. Huffman, PhD, PE rhuffman@agriwaste.com EHS: Soil Parameters Soil Evaluation By: Special Conditions/Notes: LTAR: 0.30 gpd/ft2 Design Parameters Type of Establishment: Residence,5 or fewer bedrooms Unit: Bedroom #of Units: 4 Septic Tank Specifications Min.Tank Capacity: 1,000 gal Exterior Interior Actual Tank Volume: 1,250 gal Length: 125.5 119.5 in. Tank Manufacturer: Shoaf Width: 65.5 59.5 in. Tank Model: TS 1250 STB Depth: 61.5 54.5 in. Primary Draintield Specitications Type of Distribution: Parallel Distribution Box Trench Bottom Area: 1600 ft2 Trench Media: Chambers Minimum Drain Line: 400 ft Trench Width: 3 ft Actual Drain Line: 400 ft Trench Depth: in. Number of Lines: 4 (or as specified on permit) Minimum Line Spacing: 9 ft O.C. Wastewater Treatment System Design Calculations Project: Cardiff Glyn- Lot 68 Location: 5064 Throneburg Rd Catawba, NC 28609 County: Catawba Septic Tank Sizing Daily Flow Estimate: Unit #of Units Flow/Unit Flow/Day Bedroom 4 120 480 Q= 480 gpd Septic Tank Minimum Capacity: Per NCAC T15A:18A .1952(b)(1): For individual residences with 4 bedrooms, Minimum Liquid Capacity (V)= 1,000 gal Septic Tank Specs: Manufacturer: Shoaf Model: TS 1250 STB Volume: 1,250 gal Weight: 11,000 lbs Exterior Interior Length: 125.5 119.5 in. Width: 65.5 59.5 in. Depth: 61.5 54.5 in. Shape of Risers: Circular Diameter: 2.00 ft Pump Tank Storage & Float Settings Project: Cardiff Glyn - Lot 68 Location: 5064 Throneburg Rd Catawba, NC 28609 County: Catawba Tank Manufacturer Shoaf Tank Model TS 1275 PT Interior Height(in.) 60.5 in. Avg. Storage 21.07 gal/in. Primary System Elevations, measured from bottom towards top(0 = Interior Bottom of Tank): Top of pump (including 4" block) 16.1 in. (Pump height= 12 1/8") Pump Off 18.0 in. Pump On 26.5 in. (set for dose volume) Alarm On 32.5 in. (6 in. above On Float) Emergency Storage Available Pump Tank 590 gal Days of Storage 1.23 days (determined from"interior top of tank"-"High Water Alarm") Repair System Elevations, measured from bottom towards top(0 =Interior Bottom of Tank): Top of pump (including 4" block) 16.4 in. (Pump height = 12 13/32") Pump Off 18.5 in. Pump On 27.0 in. (set for dose volume) Alarm On 33.0 in. (6 in. above On Float) Emergency Storage Available Pump Tank 579 gal Days of Storage 1.21 days (determined from"interior top of tank"-"High Water Alarm") ELEVATIONS Project:Cardiff Glyn-Lot 68 Location:5064 Throneburg Rd Catawba,NC 28609 County: Catawba Benchmark IP NE corner Lot 68 BM Elev 1028.2 ft Septic Tank 1,250 gal Ground Surface ft Depth of Soil Cover 28 in. 2.33 ft Overall Ht of Tank 61.5 In. 5.13 ft Elev,Base of Tank 1007.74 ft Ht to 4"Inlet Invert 50 in, 4.17 ft Elev,4"Inlet Invert 1011.91 ft Ht to 4"Outlet Invert 48 in. 4.00 ft Elev,4"Outlet Invert 1011.74 ft Gravel Base, 6 in. 0.50 ft Elev,Bot of Excavation 1007.24 ft Pump Tank 1287 gal Ground Surface 1014.701ft Depth of Soil Cover 27 in. 2.25 ft Overall lit of Tank 67.5 in. 5.63 ft Elev,Base of Tank 1006.83 ft lit to 4"Inlet Invert 57 In. 4.75 ft Elev,4"Inlet Invert 1011.58 ft lit to 2"Outlet Invert 58 in. 4.83 ft Elev,2"Outlet Invert 1011.66 ft Gravel Base j in. 0.50 ft Elev,Bot of Excavation 1006.33 ft ST Inlet Pipe Grade @ Stub-out 1014.12 ft Depth of Stub-out,top 1.5 ft Elev,Stub-out Invert 1012.27 ft Elev @ ST Inlet Invert 1011.91 ft Length _ 15 ft Slope 2.4 Pipe,ST to PT ID 4 in. 0.33 ft OD 4.5 in. 0.38 ft Elev,ST Outlet Invert 1011.74 ft Elev,PT Inlet Invert 1011.58 ft Length 11.2 ft Slope 1.5 % Cover over inlet pipe 2.94 ft Pump Reqmt. Floor Thickness 4 in. 0.33 ft Elev,Pump Tank Floor 1007.16 ft Pump Block Ht. ' in. 0.33 ft Elev,Pump Intake 1007.49 ft Grade @ Primary D-box 1024.20Ift Grade(81 Repair D-box 1027.10 ft Min.Cover in. 1.50 ft Max Elev,Primary 1022.70 ft Max Elev,Repair 1025.60 ft Elev Diff,Primary 15.21 ft Elev Diff,Repair 18.11 ft Drainfield Design Project Cardiff Glyn-Lot 68 Location 5064 Throneburg Rd Catawba,NC 28609 County Catawba Drainfield Sizing Primary LTAR 0.3 gpd/ft2 Daily Design Flow 480 gpd Type of Drainfield Media Chambers Req.Drainfield Area 1,600 ft2 Required Drainline Trench Width,Eff. 3 ft After 25%Reduction 400 ft Required Drainline 533 ft Minimum Line Spacing 9 ft(O.C.) Repair LTAR 0.3 gpd/ft2 Daily Design Flow 480 gpd Type of Drainfield Media Chambers Req.Drainfield Area 1,600 ft2 Required Drainline Trench Width,Eff. 3 ft After 25%Reduction 400 ft Required Drainline 533 ft Minimum Line Spacing 9 ft(O.C.) Drainfield Layout Elevation Line Length Used as Used as Line Use Flag Color (ft) (ft) Pf nxar &t) Repair(ft) 1 Layout Line purple 1020.0 113 102.0 2 Layout Line blue 1021.0 109 102.0 3 Layout Line white 1022.1 106 98.0 4 Layout Line red 1022.8 107 98.0 5 Layout Line purple 1023.7 109 82.0 6 Layout Line blue 1024.3 68 7 Layout Line white 1024.7 73 8 Layout Line red 1025.3 81 78.0 9 Layout Line purple 1025.6 88 82.0 10 Layout Line blue 1026.4 86 82.0 11 Layout Line white 1026.7 89 78.0 Total 1029 400 402 Count 11 4 5 Note:Line length totals are shown to the nearest foot. For Chambers or Low-profile Chambers: Effective trench lengths are shown.Add 1'for total installation length. PRESSURE MANIFOLD DESIGN (Primary) Site Information Project: Cardiff Glyn-Lot 68 Location: 5064 Throneburg Rd Catawba,NC 28609 County: Catawba Design Information Estimated Daily Flow 480 gal/day L.T.A.R.(from Catawba Co.) 0.3 gal/day/ft2 L.T.A.R.+5% 0.315 gal/day/ft2 Trench Width 3 ft. Line Length Required 533 ft. Length after 25%Reduction 400 ft L.T.A.R.Reduced 0.400 gal/day/ft2 L.T.A.R.Reduced+5% 0.420 gal/day/ft2 DRAINFIELD INFO.- Primary Proposed Type of System/Distribution: Pump to Pressure Manifold using Chambers Flag Line Flow Flow/Foot Line Line No. Color Length(ft) Tap (gpm) j (gpm/ft) L.T.A.R. 1 purple 102 1/2in SCH 80 5.48 0.054 0.392 2 blue 102 1/2in SCH 80 5.48 0.054 0.392 3 white 98 1/2in SCH 80 5.48 0.056 0.408 4 red 98 1/2in SCH 80 5.48 0.056 0.408 Total 400 Total 21.92 Avg. 0.40 Note:Line lengths are calculated in 4'increments to reflect use of Chambers product.2'added for endcaps. Total Run Time 21.90 min. Drainfield Capacity 261.2 gal of Drainfield Cap 68.6% (Req.Range 66-75%) Dose Volume 179.2 gal/dose Run Time/Dose 8.2 minutes Range 5-7 minutes unless uphill,checked Volume/depth 21.07 gal/in. (Per tank manufacturer's specifications) Estimated Drawdown 8.50 in. Manifold Box Number of Taps 4 with 0 Split(s) Manifold Length 3.5 ft. (approximate) PRESSURE MANIFOLD SYSTEM DESIGN (Repair) Site Information Project: Cardiff Glyn-Lot 68 Location: 5064 Throneburg Rd Catawba,NC 28609 County: Catawba Design Information Estimated Daily Flow 480 gal/day L.T.A.R.(from Catawba Co.) 0.3 gal/day/ft2 L.T.A.R.+5% 0.315 gal/day/ft2 Trench Width 3 ft. Line Length Required 533 ft. Length after 25%Reduction 400 ft L.T.A.R.Reduced 0.400 gal/day/ft2 L.T.A.R.Reduced+5% 0.420 gal/day/ft2 DRAINFIELD INFO.- Repair Proposed Type of System/Distribution: Pump to Pressure Manifold using Chambers Flag Line Flow I Flow/Foot Line Line No. Color 1 Length(ft.) I (gpm) (gpm/ft) L.T.A.R. 5 purple 82 1/2in SCH 80 5.48 0.067 0.390 8 red 78 1/2in SCH 80 5.48 0.0701 0.410 9 purple 82 1/2in SCH 80 5.48 0.067 0.390 10 blue 82 1/2in SCH 80 5.48 0.067 0.390 11 white 78 1/2in SCH 80 5.48 0.070I 0.410 Total 402 Total 27.40 Avg.l 0.40 Note:Line lengths are calculated in 4'increments to reflect use of Chambers product.2'added for endcaps. Total Run Time 17.52 min. Drainfield Capacity 262.5 gal %of Drainfield Cap 68.2% (Req.Range 66-75%) Dose Volume 179.0 gal/dose Run Time/Dose 6.5 minutes Range 5-7 minutes unless uphill,checked Volume/depth 21.07 gal/in. (Per tank manufacturer's specifications) Estimated Drawdown 8.50 in. Manifold Box Number of Taps 5 with 0 Split(s) Manifold Length 4.0 ft. (approximate) r PUMP DESIGN System(initial/repair): Primary Project: Cardiff Glyn-Lot 68 Location: 5064 Throneburg Rd Catawba,NC 28609 County: Catawba Friction Losses Suction Head 0 ft (submersible 0) Elev.Difference(highest point from pump) 15.21 ft Design Pressure At Outlet 2 ft Supply Line-1.5"Schedule 40 PVC Pipe Diameter,Nominal' 1.51in. Pipe Diameter(ID) 1.59 in. Flow 21.92 gpm Pipe Length 169.61ft Velocity 3.54 ft/sec Pipe Length for Fittings 16.96 ft Meets requirement that 2 ft/s<v<5 ft/s. Equivalent Length 186.56 ft Estimated Friction Loss in Supply Line 5.83 ft Pressure Filter Friction Loss 0.23 ft (from manufacturer) Friction Loss-Taps/Special Fittings 3.5 ft TOTAL 26.77 ft. Flow for Anti-Siphon Hole Hole Diameter 3/161in. Hole Flowrate 2.14 gpm Pump Efficiency 0.7 (assumed,typical) Motor Efficiency 0.9 (assumed for electric pumps) Flow 24.06 gpm Required Horsepower 0.26 hp TDH 26.77 ft Pump Selection Manufacturer: Zoeller Model: N152 Horsepower: 0.4 PUMP PERFORMANCE CURVE MODEL 151/152/153 50 14- 150 _ ::j 'bx 152 70 Operating I a- 161 Point - 20 15 4- 10 \\\\\\\\\ - 5 10 20 30 40 60 60 70 60 90 100 GALLONS LRERR O N 60 1p 160 260 2/0 2i0 sb 7i0 FLOW PER MINU E WOOS PUMP DESIGN System(initial/repair): Repair Project: Cardiff Glyn-Lot 68 Location: 5064 Throneburg Rd Catawba,NC 28609 County: Catawba Friction Losses Suction Head' o'fl (submersible 0) Elev.Difference(highest point from pump) 16.11 ft Design Pressure At Outlet' 2 ft Supply Line-1.5"Schedule 40 PVC Pipe Diameter,Nominal 1.5 in. Pipe Diameter(ID) 1.59 in. Flow 27.4 gpm Pipe Length 232:9 ft Velocity 4.43 ft/s Pipe Length for Fittings 23.29 ft Meets requirement that 2 ftls<v<5 ft/s. Equivalent Length 256.19 ft Estimated Friction Loss in Supply Line 12.10 ft Pressure Filter Friction Loss 0.23 ft (from manufacturer) Friction Loss-Taps/Special Fittings 3.5 ft TOTAL 35.94 ft. Flow for Anti-Siphon Hole Hole Diameter 3/16 in. Hole Flowrate 2.46 gpm Pump Efficiency 0.7(assumed,typical) Motor Efficiency 0.9(assumed for electric pumps) Flow 29.88 gpm Required Horsepower 0.43 hp TDH 35.94 ft. Pump Selection Manufacturer: Zoeller Model: N140 Horsepower: 1 PUMP PERFORMANCE CURVE MODEL 140/4140/145/4145 76 70 L. A- N 1{ 00 F tlOperating E Point Rw- 1 r0 ss 111 - is s t.ee ua NM •140 M ID i O 60 M M d9 90 GALLOWS itrcw' 0 b 140 310 3r1 FLOW PER MAIM , , Attachment 2: Soil Boring Description Sheets I COUNTY:CatawbaCo._ SOIL/SITE EVALUATION for ON-SITE WASTEWATER SYSTEM (Complete all fields in full) CLIENT: Adams Homes APPLICATION DATE ADDRESS: Lot 68 Colchester Court.Catawba,NC 28609 DATE EVALUATED: 8/09/22 PROPOSED FACILITY: Single Family Residence PROPOSED DESIGN FLOW(.1949): 480 GPD PROPERTY SIZE: .93 ac. LOCATION OF SITE:Lot 68 Colchester Court.Catawba,NC 28609 PROPERTY RECORDED: WATER SUPPLY: ❑Private ,Public ❑Well ❑Spring ❑Other EVALUATION METHOD: X Auger Boring ❑Pit 0 Cut TYPE OF WASTEWATER: yl Sewage ❑ Industrial Process 0 Mixed • • • • P R SOIL MORPHOLOGY OTHER F (.1941) PROFILE FACTORS 1 .1940 L LANDSCAPE HORIZON E POSITION/ DEPTH PROFILE .1942 # SLOPE% ON .1941 .1941 SOIL .1943 .195( .1944 CLASS STRUCTURE/ CONSISTENCE/ WETNESS/ SOIL SAPR RESTR <AR TEXTURE MINERALOGY COLOR DEPTH 0 HORIZ CLASS 0-18" SCL;GR SS;SP;FR - 36" - Provisionally - Suitable 3% 18-36" C;SBK SS;SP;FI SB 0.3 1 0-15" SCL;GR SS;SP;FR 36" - - 3% Provisionallv 15-36" C;SBK SS;SP;FI Suitable SB 2 0.3 0-8" SCL;GR SS;SP;FR 36" - - Provisionally Suitable 5% SB 8-36" C;SBK SS;SP;Fl 3 0.3 SB 0-4" SCL;GR SS;SP;FR - 34' - Provisionally 3% Suitable 4 4-26" C;SBK SS;SP;FI 26-34" 0.3 CL;WSBK SS;SP;FR 34+ CL;MA SS;SP;FR DESCRIPTION INITIAL SYSTEM REPAIR SYSTEM OTHER FACTORS(.1946): SITE CLASSIFICATION(.1948): Available Space(.I945) Provisionally Provisionally Suitable Suitable EVALUATED BY: Jeff Vaughan 25%Reduction 25%Reduction OTHER(S)PRESENT: Trevor Hackney System Type(s) Chambers Chambers Pressure Manifold Pressure Manifold Site LTAR 0.3 GPD/Ft2 0.3 GPD/Ft2 COMMENTS Updated February 2014 • a LEGEND use the following standard abbreviations SOIL CONVENTIONAL LPP MINERALOGY/ LANDSCAPE POSITION GROUP TEXTURE .1955 LTAR* ,1957 LTAR* CONSISTENCE STRUCTURE CC(Concave Slope) I S(Sand) 1.2-0.8 0.6-0.4 SEXP(Slightly Expansive) G(Single Grain) CV(Convex Slope) LS(Loamy Sand) EXP(Expansive) M(Massive) D(Drainage Way) CR(Crumb) DS(Debris Slump) II SL(Sandy Loam) 0.8-0.6 0.4-0.3 GR(Granular) FP(Flood Plain) L(Loam) SBK(Subangular Blocky) FS(Foot Slope) ABK(Angular Blocky) H(Head Slope) III Si(Silt) 0.6-0.3 0.3-0.15 PL(Platy) L(Linear Slope) SiCL(Silty Clay Loam) PR(Prismatic) N(Nose Slope) CL(Clay Loam) R(Ridge) SCL(Sandy Clay Loam) MOIST WET S(Shoulder Slope) SiL(Silt Loam) T(Terrace) VFR(Very Friable) NS(Non-sticky) IV SC(Sandy Clay) 0.4-0.1 0.2-0.05 FR(Friable) SS(Slightly Sticky) SiC(Silty Clay) FI(Firm) S(Sticky) C(Clay) VFI(Very Firm v.Very Sticky) VS(Very Sticky) 0(Organic) None None EFI(Extremely Firm) NP(Non-plastic) SP(Slightly Plastic) *Adjust LTAR due to depth,consistence,structure,soil wetness,landscape,position,wastewater flow and quality. P(Plastic) NOTES VP(Very Plastic) HORIZON DEPTH In inches below natural soil surface DEPTH OF FILL In inches from land surface RESTRICTIVE HORIZON Thickness and depth from land surface SAPROLITE S(suitable)or U(unsuitable) SOIL WETNESS Inches from land surface to free water or inches from land surface to soil colors with chroma 2 or less-record Munsell color chip designation CLASSIFICATION S(Suitable),PS(Provisionally Suitable),or U(Unsuitable) Evaluation of saprolite shall be by pits. Long-term Acceptance Rate(LTAR):gal/day/112 Show .rofile locations and other site features dimensions,reference or benchmark,and North. IIIrffUiU."fl.ii ■ all ■■ ■ ■■■ ■ ■■■ ■ ■■■■■ ■ ■■ IIIII .. 0.0 ■■ ■ 1... ini ■ ■■■ ■■■■■ 1 ■■■■ ■■■■ ■■iiiii: ■■■■■■■■■ ■■■ ....milli.......aim.... ■■■■■■■ iiuP . piii.iiiuiiu1r Updated February 2014 SOIL/SITE EVALUATION Sheet_3_of_3_ (Continuation Sheet-Complete all field in full) PROPERTY ID 4: DATE OF EVALUATION: COUNTY: Catawba Co. • • • . • P R SOIL MORPHOLOGY OTHER 0 F (.1941) PROFILE FACTORS I .1940 - L LANDSCAP HORIZ 1942 E ON .1941 .1941 SOIL .1943 .1956 .1944 PROFILE ii POSITION/ DEPTH STRUCTURE/ CONSISTENCE/ WETNESS/ SOIL SAPRO RESTR CLASS SLOPE (IN.) TEXTURE MINERALOGY COLOR DEPTH CLASS HORIZ <AR 3% 0-14" SCL;WSBK SS;SP;FR 3 Saprolite Provisionally 14-31" - suitable C;SBK SS;SP;FI 0.3 5 31+ SiL;MA SS;SP;FR COMMENTS: Updated February 2014 0 Ji • Attachment 3: Additional Documentation w„ ON `A1Nf OO V0MV1V3 ' `` ' ,'� ri. (COO i#uS) as -raw SAVatHf1W r '8 (OESL#t!S) OH �af103NOHHl • r' '- '''•''d 'k oiNVId 311S ilVH3A° 0 ,, NOISIAIa8f1S NATO JIlaliVO �a if a ae °R @ e c l € @i a t ie e s , @@ $ F a y g's ' a xLxRsY_ d4 " i. ' F 4 y ° # '§ i e P i 8 3 d 1 iRAg @ • F? i ! k; i1$$ 1a Q b @@E,,ixd l i c i li f@tl $$ 1W 5 � gY35 S 'a 8 @ ! P C , 9 8 , o ' !96# iSl# d @!tK a; Pe , ,tl G 1 = 1 i I, P1 €i,II i 1: i p 11 1 i ii i i ft '61 @ elf s tI 1 „ if 11 1 III HI ® y i_-- --_'°�' __ iie r 5si tliitI1 8 I! 111til1 7.—► Z o1131 X§ li 4 a s 41 @a 3 �c a /e 4i @ s4. @, 5d@ \ € yy ay; r s15 y� x,,• EFaigp$�1p$9s 1 11 MI �r / ��/i:� 4dT�p�px�p�Y.Gr ynh. 1,1!i,4 4 9 i8e g € 1e 1 ., ��s$ w - �a�cm_•ar`,!_ / of R tey r p : +ice --� i , q$ rr a„o7I L 3f...J" 1 i' .fix t: .c,, 11 'r/ "l'r-•_-_ `=C,-- 1 . L--- om ,I I, sk' -` ''-® 11\ R`! ili g1,1 R`1'x 1.1 ...0J, �-,7 � �!�"��n • 4 i _` `��+.-���..,.•"IL,, _ i!i �PE(r Y7, 1{' yy '' p iRY 1/M'• r/�'_' _ i � `1, ti! t! 3X 1 , , e !; - ,,,,,-, �•".. ,.N,„„,,,.__yi j' /',4 �,®gib ,,y ',, ;�r�,'~,:r-im �• - ® /r b 1�A. -t r•r^_�_ {„u`•tl• r . , 1•, it ' 0 4 ',Jill 1 �: \ r/®^ill✓ /li ,�, •w� 41 -�(t r f 111ef! i ``ry` I ^.:�` - tt•. f /71 eb /, E4 r/,rr ,� m ,,,-4c .;Lu.V.� JI Iff 1f C\ 'lit•.`•.4 ,!/I a'II ®. ' 4' •1- 7Y 1t s�-1 `l J y 11 . a�g 1 g ,�'` ,4 r , ,i/J, ~R.Y-,r, '.a-•T. %�r` s ,I Ii /i�; I-�,�'a"n s',Y-' I i iI� _..r.r •. z _/ `® 7 t / 4Q $.- , 'r ,rfq�1,,/eg l,ip r_C- 'lY ,1 "1', / -_if __ .:„1 I.(' ,,, ;.,..'" . .._; /, -'' - o•:` :+ <,. *c";qr.,,," t gN/Y , t 1 , s„!/' r r igy r"j' t- :- `\. RY` mow; ,}off, C .r 1i * ,` ITh14 , / 1; ,,,,,, e.• \ .`, ! �1' b ,:t a `"� q ,,,jI ,f, x:j. ip 3 ll �YI4FII- m yam fi rx^` R s >Y" icf\ X, '� *J' /r GS'I' , ' ,- It - - =—if"', '-mo t® `'' �`•''qf' '�` x s•s ihe.;y/j - p 6 l F 4 1" t Aye ;, fid irr r iii 1_ Ili "° ` `\ >v � < :. 7:•., .oi 1 .x�-Lm*" x`�i09 f1 O ` illiiiii.,_y /1 -- t 1 PI 4 inn®y ` -,,`, \..\,®✓ `,,,, > / •,/'lam!, 1 4�` 9 it l�r ,r� S R�'' `\', ti 'j' :l yY;`; \®�$ .`J�PP i ,i'g .'3, Zr 8 ..D 1 R x w• ; talr( '1:�' ei;!; ,, f j, Li ,�+rf ;�, l' o 4g ` i ` 1 1 r ;i', 1•[e '[�'h ! 1�� i i 1 ylt i ` p p, i r I ..J ,, uP ‘I j i I ; I 1 f \, g! R 1 i ; 1 E g S I i1 ; . i ; !} 3 Yg -y , i II j ' 1 ; 1 Hn kOI1 , 1Y \ ; i 1ig I . . ,, ,11 . ff i ' 1 id I 1 5591mr $ , , _ -:- . • 'I/ I I I... P9ltEd114e1811 $ 1 • an ,,,.a, FiA [ [ r r t .xuwaxw ag3ru aua,xvau„vgunauswvgnxw xxsn xwWsww nwxnanwaaap,wa�snnenxixl�naaYdax tla vvn aggxaxlnVxa AWV tlUMaxi.KI 1V NaO xa artl�cNitvNaaa eo uagaoW,aYaigHSHw xOOxLw,a sxaiV�ln>gasf toxWW4 YNo.,a TV J �'A COS CATAWBA COUNTY 7( 100A SOUTHWEST BLVD E-' M1� NEWTON,NORTH CAROLINA 28658 RECEIPT PHONE:828.465.8399 \ � Friday,May 12,2023 j$4'1 5M www.catawbacountync.gov PAYOR: Agri-Waste Technology, Inc. Agri-Waste Technology,Inc.(Vaughan,Jeff) PAYMENTS TRANSACTION NUMBER: TRC-63909093-12-05-2023 PAYMENT DATE: 05/12/2023 PAYMENT TYPE: Credit Card 305184525 INVOICE NUMBER ACCOUNT FEE NAME FEE AMOUNT 05-23-422626 110-580200-663000 AOWE S135.00 TOTAL PAYMENTS: $135.00 RBPR-05-2023-44351 CASE TYPE: Residential Building Plan Review WORK CLASS: Building New SITE ADDRESS: COLCHESTER CT,CATAWBA NC 28609 Applicant AGRI-WASTE TECHNOLOGY INC,501 N SALEM ST SUITE 203,APEX NC 27502 B:9193676320 JMORAN@AGRIWASTE.COM Owner ADAMS HOMES AEC,LLC,3401 ST.VARDELL LN SUITE B,CHARLOTTE NC 28217 B:7045584527 BCASHION@ADAMSHOMES.COM Paid By AGRI-WASTE TECHNOLOGY,INC.,, C:9193676313 **NO PEOPLESOFT ACCOUNT ASSIGNED** receipt 05/12/2023 15:47 Page I of