HomeMy WebLinkAboutAUTH-05-2023-194963.TIF 403' CATAWBA COUNTY Case# AUTI I-05-2023-194963
�C t Z Public Health Department Subdivision
< 0' � Environmental Health Division P1N# 461604634423
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 47
18 s.
Site Address: 4903 KISER ISLAND RD, TERRELL NC 28682
Name on Permit: *FOUNDATION HOMES RESIDENTIAL LLC
Property Size: Acres 0.46
Directions: Take NC 16 S to Hwy 150 E, Left on NC 150 E, Right on Kiser Island
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence-
Basement? NO Basement Plumbing? No Bedrooms: 3
Water Supply: Private Well Maximum Occupants: 6
Soil LTAR: 0.275 g.p.d.lft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 50%REDUCTION VERTICAL
System Classification: IVA-ANY SYSTEM WITH LPP DISTRIBUTION
Septic Tank: New Tank: 1,000 gal
Pump Tank 1.000 gal Grease Trap_gal
Dosing Volume 184 gal Pump Specs: 30 GPM @ 11.7 TDH
Pressure Head 2 ft Draw Down 8.7 in
Drainfield: Total Area: 672 sq ft Total Trench Length: 224 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 40 in
Minimum Soil Cover: 12 in Minimum Trench Separation: 13 ft on center
Number of Drain Lines: 6 Trench Width: 2 ft
Distribution: LPP
Pre Treatment: NONE
Pump Required ***** Operator Required
Additional Specifications:
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions<<<<<
PROPOSED REPAIR
Repair System Required? Not Required Soil LIAR: 9•P•d.lft2
Proposed System:
System Classification:
05/18/2023 15:36